A sensitive LC-MS/MS methotrexate assay capable of assessing adherence to methotrexate therapy in rheumatoid arthritis.
adherence
mass spectrometry
methotrexate
rheumatoid arthritis
Journal
Clinical chemistry and laboratory medicine
ISSN: 1437-4331
Titre abrégé: Clin Chem Lab Med
Pays: Germany
ID NLM: 9806306
Informations de publication
Date de publication:
26 01 2024
26 01 2024
Historique:
received:
05
04
2023
accepted:
07
07
2023
medline:
28
11
2023
pubmed:
3
8
2023
entrez:
3
8
2023
Statut:
epublish
Résumé
To develop a sensitive liquid chromatography-tandem mass spectrometry method capable of measuring serum methotrexate in patients with rheumatoid arthritis to assess adherence to drug treatment. Isotopically labelled internal standard and deionised water were added to sample prior to solid phase extraction using a Waters Oasis Max ion-exchange 96-well plate. Following extraction, samples were analysed by LC-MS/MS on a TQS-micro mass spectrometer. Mean recovery was 107 % for four different concentrations of methotrexate spiked into seven patient samples, whilst post extraction spiking gave a mean recovery of 100 %. Between-batch and within-batch CVs were ≤6 % at three different concentrations of methotrexate in fresh frozen plasma. Mean bias was <5 % for between-batch and within batch analysis at three different weighed in concentrations of methotrexate certified reference material. The lower limit of quantification of the assay was 0.1 nmol/L with linearity up to approximately 100 nmol/L. Dilution linearity studies were used to validate the dilution of patient samples prior to analysis. There was no significant interference in the method from lipaemia, haemolysis or icterus. A sensitive LC-MS/MS assay for methotrexate has been developed and validated. The method has been used to measure methotrexate adherence in patient samples from clinical trials and could be used in future research to assess the ability of the assay as a biofeedback intervention to improve adherence to methotrexate therapy.
Identifiants
pubmed: 37533325
pii: cclm-2023-0350
doi: 10.1515/cclm-2023-0350
doi:
Substances chimiques
Methotrexate
YL5FZ2Y5U1
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
111-117Informations de copyright
© 2023 Walter de Gruyter GmbH, Berlin/Boston.
Références
Smolen, JS, Landewe, RB, Bijlsma, JW, Burmester, GR, Dougados, M, Kerschbaumer, A, et al.. EULAR recommendations for the management of rheumatoid arthritis with synthetic and biological disease-modifying antirheumatic drugs: 2019 update. Ann Rheum Dis 2020;79:685–99. https://doi.org/10.1136/annrheumdis-2019-216655 .
doi: 10.1136/annrheumdis-2019-216655
National Institute for Health and Care Excellence . Rheumatoid arthritis in adults: management. NG100 ; 2018. https://www.nice.org.uk/guidance/ng100/resources/rheumatoid-arthritis-in-adults-management-pdf-66141531233989 [Accessed 1 Feb 2023].
Bluett, J, Riba-Garcia, I, Verstappen, SM, Wendling, T, Ogungbenro, Unwin, RD, et al.. Development and validation of a methotrexate adherence assay. Ann Rheum Dis 2019;78:1192–7. https://doi.org/10.1136/annrheumdis-2019-215446 .
doi: 10.1136/annrheumdis-2019-215446
Barton, A, Jani, M, Bundy, C, Bluett, J, McDonald, S, Keevil, B, et al.. Translating research into clinical practice: quality improvement to halve non-adherance to methotrexate. Rheumatology 2020;60:125–31. https://doi.org/10.1093/rheumatology/keaa214 .
Food and Drug Administration, Department of Health and Health Services . Guidance for industry. Bioanalytical method evaluation . https://www.fda.gov/files/drugs/published/Bioanalytical-Method-Validation-Guidance-for-Industry.pdf [Accessed 7 Jul 2023].
McTaggart, MP, Keevil, BG. A rapid LC-MS/MS assay for the measurement of serum methotrexate in patients who have received high doses for chemotherapy. Ann Clin Biochem 2021;58:599–604. https://doi.org/10.1177/00045632211031284 .
doi: 10.1177/00045632211031284
ClinicalTrials.gov . Methotrexate use improvement in rheumatoid arthritis using biomarker feedback . https://clinicaltrials.gov/ct2/show/NCT03913728 [Accessed 7 Jul 2023].
Bluett, J, Hyrich, KL, Keevil, B, Doran, P, Barton, A. Feasibility study of methotrexate use improvement in rheumatoid arthritis using biomarker feedback. Rheumatology 2023;62(2 Suppl):P106.
Engel, A, Ruhe, L, Singh, N, Wright, JA, Liesch, F, Bauland, F, et al.. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of methotrexate in human serum and plasma. Clin Chem Lab Med 2023;61:1917–29. https://doi.org/10.1515/cclm-2022-1001 .
doi: 10.1515/cclm-2022-1001