[Validation of the German language version of the Chronic Ear Survey and its psychometric comparison with an established German language measurement instrument. German version].
Validierung der deutschsprachigen Version des Chronic Ear Survey und dessen psychometrischer Vergleich mit einem etablierten deutschsprachigen Messinstrument.
Epidemiologic measurements
Middle ear
Otitis media
Quality of life
Questionnaire
Journal
HNO
ISSN: 1433-0458
Titre abrégé: HNO
Pays: Germany
ID NLM: 2985099R
Informations de publication
Date de publication:
Sep 2023
Sep 2023
Historique:
accepted:
26
06
2023
medline:
29
8
2023
pubmed:
4
8
2023
entrez:
4
8
2023
Statut:
ppublish
Résumé
With the Chronic Ear Survey (CES), a validated measurement instrument for the assessment of disease-specific health-related quality of life (HRQoL) has been available internationally since 2000. The aim of this study was to provide a validated German version of this international instrument and to compare it with the German Chronic Otitis Media Outcome Test 15 (COMOT-15). The CES was translated into German via a forward-backward translation process. For validation, 79 patients with COM undergoing middle ear surgery were prospectively included. HRQoL was determined preoperatively and 6 months postoperatively using the CES and the COMOT-15. Pure tone audiometry was also performed at both measurement time points. In the control examination, an additional retrospective assessment of the preoperative situation was additionally performed using the CES and the COMOT-15 to assess the response shift. The determined psychometric characteristics were internal consistency, test-retest reliability, discrimination validity, agreement validity, responsiveness, and response shift for both measurement instruments. Convergent validity of both measurement instruments was assessed using linear regression. On the basis of the CES, patients with COM could be reliably distinguished from patients with healthy ears. The CES showed satisfactory reliability with high internal consistency (Cronbach α 0.65-0.85) and high retest reliability (r > 0.8). The global assessment of HRQoL impairment correlated very well with the scores of the CES (r = 0.51). In addition, it showed a high sensitivity to change (standardized response mean -0.86). Compared to the COMOT-15, it showed a lower response shift (effect size -0.17 vs. 0.44). Both measurement instruments correlated only slightly with air conduction hearing threshold (r = 0.29 and r = 0.24, respectively). The concordant validity of both measurement instruments was high (r = 0.68). The German version of the CES shows satisfactory psychometric characteristics, so that its use can be recommended. The CES focuses on the influence of ear symptoms on HRQoL, whereas the COMOT-15 also includes functional and psychological aspects. Due to only minor response shift effects, the CES is particularly suitable for studies with multiple repeat measurements. HINTERGRUND: Mit dem Chronic Ear Survey (CES) steht seit 2000 ein validiertes Messinstrument zur Erfassung der krankheitsspezifischen bzw. gesundheitsbezogenen Lebensqualität (HRQoL) international zur Verfügung. Ziel der Studie war es, für dieses internationale Messinstrument eine validierte deutschsprachige Fassung zur Verfügung zu stellen und diese mit dem deutschen Chronic Otitis Media Outcome Test 15 (COMOT-15) zu vergleichen. Der CES wurde über einen Vorwärts-rückwärts-Übersetzungsprozess in die deutsche Sprache transferiert. Zur Validierung wurden 79 Patient:innen mit einer COM, bei denen eine Mittelohroperation durchgeführt wurde, prospektiv in die Studie eingeschlossen. Die HRQoL wurde präoperativ und 6 Monate postoperativ mit dem CES und dem COMOT-15 bestimmt. Zu beiden Messzeitpunkten erfolgte auch eine Reintonaudiometrie. In der Kontrolluntersuchung wurde zusätzlich eine rückwirkende Beurteilung der präoperativen Situation anhand des CES und des COMOT-15 zur Bestimmung des Response-Shifts durchgeführt. Als psychometrische Kenndaten wurden die interne Konsistenz, die Test-Retest-Reliabilität, die Diskriminationsvalidität, die Übereinstimmungsvalidität, die Responsivität für beide Messinstrumente bestimmt. Die konvergente Validität beider Messinstrumente wurde anhand einer linearen Regression bewertet. Anhand des CES konnten Patient:innen mit COM von Ohrgesunden sicher unterschieden werden. Der CES zeigte eine sehr gute Reliabilität mit hoher interner Konsistenz (Cronbach‑α 0,65–0,85) und hoher Retest-Reliabilität (r > 0,8). Die globale Einschätzung der Beeinträchtigung der HRQoL korrelierte sehr gut mit den Scores des CES (r = 0,51). Zudem zeigte er eine hohe Änderungssensitivität („standardized response mean“ −0,86). Im Vergleich zum COMOT-15 zeigte sich ein geringerer Response-Shift (Effektstärke −0,17 vs. 0,44). Beide Messinstrumente korrelierten nur gering mit der Luftleitungshörschwelle (r = 0,29 bzw. r = 0,24). Die konkordante Validität beider Messinstrumente war hoch (r = 0,68). Die deutsche Version des CES weist zufriedenstellende psychometrische Kenndaten auf, sodass das Einsatz empfohlen werden kann. Der CES legt hierbei den Fokus auf den Einfluss der Ohrsymptomatik auf die HRQoL, wohingegen der COMOT-15 auch funktionelle und psychologische Aspekte miteinschließt. Aufgrund nur geringer Response-Shift-Effekte eignet sich der CES insbesondere für Untersuchungen mit mehreren Wiederholungsmessungen.
Sections du résumé
BACKGROUND
BACKGROUND
With the Chronic Ear Survey (CES), a validated measurement instrument for the assessment of disease-specific health-related quality of life (HRQoL) has been available internationally since 2000. The aim of this study was to provide a validated German version of this international instrument and to compare it with the German Chronic Otitis Media Outcome Test 15 (COMOT-15).
METHODOLOGY
METHODS
The CES was translated into German via a forward-backward translation process. For validation, 79 patients with COM undergoing middle ear surgery were prospectively included. HRQoL was determined preoperatively and 6 months postoperatively using the CES and the COMOT-15. Pure tone audiometry was also performed at both measurement time points. In the control examination, an additional retrospective assessment of the preoperative situation was additionally performed using the CES and the COMOT-15 to assess the response shift. The determined psychometric characteristics were internal consistency, test-retest reliability, discrimination validity, agreement validity, responsiveness, and response shift for both measurement instruments. Convergent validity of both measurement instruments was assessed using linear regression.
RESULTS
RESULTS
On the basis of the CES, patients with COM could be reliably distinguished from patients with healthy ears. The CES showed satisfactory reliability with high internal consistency (Cronbach α 0.65-0.85) and high retest reliability (r > 0.8). The global assessment of HRQoL impairment correlated very well with the scores of the CES (r = 0.51). In addition, it showed a high sensitivity to change (standardized response mean -0.86). Compared to the COMOT-15, it showed a lower response shift (effect size -0.17 vs. 0.44). Both measurement instruments correlated only slightly with air conduction hearing threshold (r = 0.29 and r = 0.24, respectively). The concordant validity of both measurement instruments was high (r = 0.68).
CONCLUSION
CONCLUSIONS
The German version of the CES shows satisfactory psychometric characteristics, so that its use can be recommended. The CES focuses on the influence of ear symptoms on HRQoL, whereas the COMOT-15 also includes functional and psychological aspects. Due to only minor response shift effects, the CES is particularly suitable for studies with multiple repeat measurements.
ZUSAMMENFASSUNG
UNASSIGNED
HINTERGRUND: Mit dem Chronic Ear Survey (CES) steht seit 2000 ein validiertes Messinstrument zur Erfassung der krankheitsspezifischen bzw. gesundheitsbezogenen Lebensqualität (HRQoL) international zur Verfügung. Ziel der Studie war es, für dieses internationale Messinstrument eine validierte deutschsprachige Fassung zur Verfügung zu stellen und diese mit dem deutschen Chronic Otitis Media Outcome Test 15 (COMOT-15) zu vergleichen.
METHODIK
METHODS
Der CES wurde über einen Vorwärts-rückwärts-Übersetzungsprozess in die deutsche Sprache transferiert. Zur Validierung wurden 79 Patient:innen mit einer COM, bei denen eine Mittelohroperation durchgeführt wurde, prospektiv in die Studie eingeschlossen. Die HRQoL wurde präoperativ und 6 Monate postoperativ mit dem CES und dem COMOT-15 bestimmt. Zu beiden Messzeitpunkten erfolgte auch eine Reintonaudiometrie. In der Kontrolluntersuchung wurde zusätzlich eine rückwirkende Beurteilung der präoperativen Situation anhand des CES und des COMOT-15 zur Bestimmung des Response-Shifts durchgeführt. Als psychometrische Kenndaten wurden die interne Konsistenz, die Test-Retest-Reliabilität, die Diskriminationsvalidität, die Übereinstimmungsvalidität, die Responsivität für beide Messinstrumente bestimmt. Die konvergente Validität beider Messinstrumente wurde anhand einer linearen Regression bewertet.
ERGEBNISSE
UNASSIGNED
Anhand des CES konnten Patient:innen mit COM von Ohrgesunden sicher unterschieden werden. Der CES zeigte eine sehr gute Reliabilität mit hoher interner Konsistenz (Cronbach‑α 0,65–0,85) und hoher Retest-Reliabilität (r > 0,8). Die globale Einschätzung der Beeinträchtigung der HRQoL korrelierte sehr gut mit den Scores des CES (r = 0,51). Zudem zeigte er eine hohe Änderungssensitivität („standardized response mean“ −0,86). Im Vergleich zum COMOT-15 zeigte sich ein geringerer Response-Shift (Effektstärke −0,17 vs. 0,44). Beide Messinstrumente korrelierten nur gering mit der Luftleitungshörschwelle (r = 0,29 bzw. r = 0,24). Die konkordante Validität beider Messinstrumente war hoch (r = 0,68).
SCHLUSSFOLGERUNG
UNASSIGNED
Die deutsche Version des CES weist zufriedenstellende psychometrische Kenndaten auf, sodass das Einsatz empfohlen werden kann. Der CES legt hierbei den Fokus auf den Einfluss der Ohrsymptomatik auf die HRQoL, wohingegen der COMOT-15 auch funktionelle und psychologische Aspekte miteinschließt. Aufgrund nur geringer Response-Shift-Effekte eignet sich der CES insbesondere für Untersuchungen mit mehreren Wiederholungsmessungen.
Autres résumés
Type: Publisher
(ger)
HINTERGRUND: Mit dem Chronic Ear Survey (CES) steht seit 2000 ein validiertes Messinstrument zur Erfassung der krankheitsspezifischen bzw. gesundheitsbezogenen Lebensqualität (HRQoL) international zur Verfügung. Ziel der Studie war es, für dieses internationale Messinstrument eine validierte deutschsprachige Fassung zur Verfügung zu stellen und diese mit dem deutschen Chronic Otitis Media Outcome Test 15 (COMOT-15) zu vergleichen.
Identifiants
pubmed: 37540235
doi: 10.1007/s00106-023-01334-6
pii: 10.1007/s00106-023-01334-6
pmc: PMC10462509
doi:
Types de publication
English Abstract
Journal Article
Langues
ger
Sous-ensembles de citation
IM
Pagination
572-582Informations de copyright
© 2023. The Author(s).
Références
J Pers Assess. 2003 Feb;80(1):99-103
pubmed: 12584072
Acta Oncol. 2002;41(3):229-37
pubmed: 12195741
Qual Life Res. 2003 May;12(3):239-49
pubmed: 12769136
Eur Arch Otorhinolaryngol. 2016 Oct;273(10):3073-81
pubmed: 26869474
HNO. 2018 Aug;66(8):578-589
pubmed: 29915938
Rehabilitation (Stuttg). 2005 Apr;44(2):100-6
pubmed: 15789293
Laryngoscope. 2000 Mar;110(3 Pt 3):32-5
pubmed: 10718413
Arch Otolaryngol Head Neck Surg. 2012 Sep;138(9):840-5
pubmed: 22986718
Br J Surg. 2003 Oct;90(10):1175-7
pubmed: 14515283
HNO. 2009 Sep;57(9):889-95
pubmed: 19629418
Soc Sci Med. 1999 Jun;48(11):1507-15
pubmed: 10400253
Ann Otol Rhinol Laryngol. 2000 Mar;109(3):249-54
pubmed: 10737305
Eur Arch Otorhinolaryngol. 2021 Sep;278(9):3217-3225
pubmed: 33011956
Health Qual Life Outcomes. 2019 Jun 18;17(1):105
pubmed: 31215443
Int J Pediatr Otorhinolaryngol. 2020 Mar;130 Suppl 1:109837
pubmed: 31883704
Eur Arch Otorhinolaryngol. 2022 Feb;279(2):703-711
pubmed: 33788035
Eur Arch Otorhinolaryngol. 2006 Mar;263(3):256-62
pubmed: 16267683
Acta Otorhinolaryngol Ital. 2017 Feb;37(1):51-57
pubmed: 28374871
Laryngorhinootologie. 2020 Mar;99(S 01):S222-S271
pubmed: 32384566
J Clin Epidemiol. 2003 May;56(5):395-407
pubmed: 12812812
Ear Hear. 1990 Dec;11(6):430-3
pubmed: 2073976
Psychol Bull. 1992 Jul;112(1):155-9
pubmed: 19565683