A Radiostereometric Analysis of Tendon Migration After Arthroscopic and Mini-Open Biceps Tenodesis: Interference Screw Versus Single Suture Anchor Fixation.
all-suture suture anchor
biceps tendon construct
biceps tenodesis
interference screw
tendon migration
Journal
The American journal of sports medicine
ISSN: 1552-3365
Titre abrégé: Am J Sports Med
Pays: United States
ID NLM: 7609541
Informations de publication
Date de publication:
09 2023
09 2023
Historique:
medline:
8
9
2023
pubmed:
7
8
2023
entrez:
7
8
2023
Statut:
ppublish
Résumé
Studies suggest that similar clinical results are achieved via arthroscopic and open biceps tenodesis (BT) techniques. To quantify the postoperative migration of the BT construct between arthroscopic suprapectoral BT (ASPBT) and open subpectoral BT (OSPBT) techniques via interference screw (IS) or single-suture suture anchor (SSSA) fixation using radiostereometric analysis. Cohort study; Level of evidence, 2. Distal migration of the biceps tendon after OSPBT with a polyetheretherketone IS, OSPBT with 1 SSSA, ASPBT with polyetheretherketone IS, and ASPBT with 2 SSSAs was measured prospectively. Patients with symptomatic biceps tendinopathy and preoperative patient-reported outcome measures (PROMs) including Constant-Murley subjective, Single Assessment Numeric Evaluation, or Patient-Reported Outcomes Measurement Information System-Upper Extremity scores were included. A tantalum bead was sutured on the proximal end of the long head of the biceps tendon before fixation of tendon tissue. Anteroposterior radiographs were performed immediately postoperatively, at 1 week, and at 3 months. Bead migration was measured, and preoperative PROMs were compared with those at latest follow-up. Of 115 patients, 94 (82%) were available for final follow-up. IS fixation yielded the least tendon migration with no difference between the open and arthroscopic approaches (4.31 vs 5.04 mm; Interference screw fixation yielded the least tendon migration whether achieved arthroscopically or open. The available data indicated that fixation with 1 SSSA but not 2 SSSAs resulted in significantly greater migration than that achieved with an IS. Despite variations in tendon migration, PROMs were similar among all groups. When SSSAs are used, tendon migration may be minimized by using ≥2 anchors.
Sections du résumé
BACKGROUND
Studies suggest that similar clinical results are achieved via arthroscopic and open biceps tenodesis (BT) techniques.
PURPOSE
To quantify the postoperative migration of the BT construct between arthroscopic suprapectoral BT (ASPBT) and open subpectoral BT (OSPBT) techniques via interference screw (IS) or single-suture suture anchor (SSSA) fixation using radiostereometric analysis.
STUDY DESIGN
Cohort study; Level of evidence, 2.
METHODS
Distal migration of the biceps tendon after OSPBT with a polyetheretherketone IS, OSPBT with 1 SSSA, ASPBT with polyetheretherketone IS, and ASPBT with 2 SSSAs was measured prospectively. Patients with symptomatic biceps tendinopathy and preoperative patient-reported outcome measures (PROMs) including Constant-Murley subjective, Single Assessment Numeric Evaluation, or Patient-Reported Outcomes Measurement Information System-Upper Extremity scores were included. A tantalum bead was sutured on the proximal end of the long head of the biceps tendon before fixation of tendon tissue. Anteroposterior radiographs were performed immediately postoperatively, at 1 week, and at 3 months. Bead migration was measured, and preoperative PROMs were compared with those at latest follow-up.
RESULTS
Of 115 patients, 94 (82%) were available for final follow-up. IS fixation yielded the least tendon migration with no difference between the open and arthroscopic approaches (4.31 vs 5.04 mm;
CONCLUSION
Interference screw fixation yielded the least tendon migration whether achieved arthroscopically or open. The available data indicated that fixation with 1 SSSA but not 2 SSSAs resulted in significantly greater migration than that achieved with an IS. Despite variations in tendon migration, PROMs were similar among all groups. When SSSAs are used, tendon migration may be minimized by using ≥2 anchors.
Identifiants
pubmed: 37548005
doi: 10.1177/03635465231187030
doi:
Substances chimiques
polyetheretherketone
31694-16-3
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM