The difference in rotation angle of the distal endotracheal tube through nasal approach.
Fiberscope
Nasotracheal intubation
Rotation
Journal
BMC anesthesiology
ISSN: 1471-2253
Titre abrégé: BMC Anesthesiol
Pays: England
ID NLM: 100968535
Informations de publication
Date de publication:
11 08 2023
11 08 2023
Historique:
received:
10
04
2023
accepted:
28
07
2023
medline:
14
8
2023
pubmed:
12
8
2023
entrez:
11
8
2023
Statut:
epublish
Résumé
Nasal intubation using a fiberoptic scope is a useful technique. In clinical practice, we have experienced difficulty in advancing the endotracheal tube (ETT) over the fiberoptic scope because of resistance to the passage of the ETT against rotation in the nasal cavity, when it gets hung up on structures of the laryngeal inlet. Several maneuvers have been proposed to overcome this difficulty. The gap between the tip of the ETT and the fiberoptic scope can be reduced using a thicker fiberoptic scope and a thinner ETT. Moreover, simultaneous rotation of the fiberoptic scope and ETT could lead to successful intubation by reducing impingement on the ETT. However, the discrepancy between these rotation angles is unclear. This observational prospective study aimed to investigate the discrepancy in the rotation angle between the ETT and fiberoptic scope during nasal intubation. The patients (aged 20-80 years) who underwent nasal intubation for oral and maxillofacial surgery participated in three sizes of preformed nasal ETT and were intubated using a fiberoptic scope. They were divided into three groups; the ETT internal diameter (ID) 6.5 mm (6.5 group), ID 7.0 mm (7.0 group), and ID 7.5 mm (7.5 group). The ETT was then inserted through the nasal cavity into the pharynx. After the fiberoptic scope was advanced through the ETT above the glottis, simultaneous rotation by both the proximal end of the fiberoptic scope and ETT was performed in 90° and 180° in both right (clockwise) and left (counterclockwise) directions, and the rotation angle at the distal end of the ETT was monitored using a video laryngoscope (Pentax-AWS). A total of 39 patients were included in the study. When both the proximal end of the fiberscope and ETT were simultaneously rotated by 90°, in the 6.5 group (n = 13), the distal end of the ETT rotated by 47.8 ± 1.5°. In the 7.0 °group (n = 13), the distal end of the ETT rotated by 45.5 ± 1.0°. In the 7.5 group (n = 13), the distal end of the ETT rotated by 39.9 ± 1.0°. When the proximal end of the fiberscope and ETT were rotated by 180°, in the 6.5 group, the distal end of the ETT rotated by 166.2 ± 2.5°. In the 7.0 group, the distal end of the ETT rotated by 145.7 ± 2.2°. In the 7.5 group, the distal end of the ETT rotated by 115.1 ± 2.0°. All rotation angles in the distal end of the ETT were significantly lower than those in both the proximal end of the fiberscope and ETT (p < 0.05). Rotating right by 180° was significantly different among the three groups (p < 0.05), although rotating right by 90° was not significantly different. Similar results were obtained for the left rotation. Simultaneous rotation by the proximal end of the ETT and fiberscope above the glottis for the nasal approach induced significant differences in the distal end of the ETT. The larger tube lagged by the resistance of the nasal passages during rotation. Therefore, the ETT does not rotate as much as the rotation angle. This prospective observational study was conducted after receiving approval from the Ethics Review Board of Kyushu University Hospital (Approval No. 30-447).
Sections du résumé
BACKGROUND
Nasal intubation using a fiberoptic scope is a useful technique. In clinical practice, we have experienced difficulty in advancing the endotracheal tube (ETT) over the fiberoptic scope because of resistance to the passage of the ETT against rotation in the nasal cavity, when it gets hung up on structures of the laryngeal inlet. Several maneuvers have been proposed to overcome this difficulty. The gap between the tip of the ETT and the fiberoptic scope can be reduced using a thicker fiberoptic scope and a thinner ETT. Moreover, simultaneous rotation of the fiberoptic scope and ETT could lead to successful intubation by reducing impingement on the ETT. However, the discrepancy between these rotation angles is unclear. This observational prospective study aimed to investigate the discrepancy in the rotation angle between the ETT and fiberoptic scope during nasal intubation.
METHODS
The patients (aged 20-80 years) who underwent nasal intubation for oral and maxillofacial surgery participated in three sizes of preformed nasal ETT and were intubated using a fiberoptic scope. They were divided into three groups; the ETT internal diameter (ID) 6.5 mm (6.5 group), ID 7.0 mm (7.0 group), and ID 7.5 mm (7.5 group). The ETT was then inserted through the nasal cavity into the pharynx. After the fiberoptic scope was advanced through the ETT above the glottis, simultaneous rotation by both the proximal end of the fiberoptic scope and ETT was performed in 90° and 180° in both right (clockwise) and left (counterclockwise) directions, and the rotation angle at the distal end of the ETT was monitored using a video laryngoscope (Pentax-AWS).
RESULTS
A total of 39 patients were included in the study. When both the proximal end of the fiberscope and ETT were simultaneously rotated by 90°, in the 6.5 group (n = 13), the distal end of the ETT rotated by 47.8 ± 1.5°. In the 7.0 °group (n = 13), the distal end of the ETT rotated by 45.5 ± 1.0°. In the 7.5 group (n = 13), the distal end of the ETT rotated by 39.9 ± 1.0°. When the proximal end of the fiberscope and ETT were rotated by 180°, in the 6.5 group, the distal end of the ETT rotated by 166.2 ± 2.5°. In the 7.0 group, the distal end of the ETT rotated by 145.7 ± 2.2°. In the 7.5 group, the distal end of the ETT rotated by 115.1 ± 2.0°. All rotation angles in the distal end of the ETT were significantly lower than those in both the proximal end of the fiberscope and ETT (p < 0.05). Rotating right by 180° was significantly different among the three groups (p < 0.05), although rotating right by 90° was not significantly different. Similar results were obtained for the left rotation.
CONCLUSION
Simultaneous rotation by the proximal end of the ETT and fiberscope above the glottis for the nasal approach induced significant differences in the distal end of the ETT. The larger tube lagged by the resistance of the nasal passages during rotation. Therefore, the ETT does not rotate as much as the rotation angle.
TRIAL REGISTRATION
This prospective observational study was conducted after receiving approval from the Ethics Review Board of Kyushu University Hospital (Approval No. 30-447).
Identifiants
pubmed: 37568085
doi: 10.1186/s12871-023-02225-7
pii: 10.1186/s12871-023-02225-7
pmc: PMC10416368
doi:
Types de publication
Observational Study
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
272Informations de copyright
© 2023. BioMed Central Ltd., part of Springer Nature.
Références
Paediatr Anaesth. 2001 Jan;11(1):49-53
pubmed: 11123731
Medicine (Baltimore). 2023 Jun 9;102(23):e34028
pubmed: 37335637
Br J Anaesth. 2017 Dec 1;119(6):1206-1212
pubmed: 29028928
Paediatr Anaesth. 2016 May;26(5):565-6
pubmed: 27059418
Anesth Prog. 2023 Mar 1;70(1):31-33
pubmed: 36995958
Can J Anaesth. 2010 Oct;57(10):913-8
pubmed: 20640542
Anesth Analg. 2000 Jun;90(6):1457-8
pubmed: 10825343
Anaesthesia. 1996 Nov;51(11):1026-8
pubmed: 8943592
Can J Anaesth. 2015 Jul;62(7):736-44
pubmed: 25907462
Anaesthesia. 1995 Aug;50(8):735-7
pubmed: 7645711
Anaesthesia. 2006 Jul;61(7):646-50
pubmed: 16792609
Anesthesiology. 2005 May;102(5):910-4
pubmed: 15851876
PLoS One. 2021 Mar 8;16(3):e0248296
pubmed: 33684167
Anaesthesia. 2013 May;68(5):472-7
pubmed: 23573843
Anesth Analg. 2018 Dec;127(6):1421-1426
pubmed: 30044295
J Anesth. 2010 Oct;24(5):819-20
pubmed: 20532573
Br J Anaesth. 2001 Aug;87(2):207-11
pubmed: 11493491
Anesth Prog. 2022 Sep 1;69(3):3-8
pubmed: 36223193
Anesthesiology. 2001 May;94(5):729-731; discussion 5A
pubmed: 11388520
Paediatr Anaesth. 2016 Apr;26(4):378-83
pubmed: 26749187