Biomechanical Investigation of Bone Screw Head Design for Extracting Stripped Screw Heads: Integration of Mechanical Tests and Finite Element Analyses.
bone screw
finite element modeling
screw head socket
screwdriver
stripped screw failure
Journal
Materials (Basel, Switzerland)
ISSN: 1996-1944
Titre abrégé: Materials (Basel)
Pays: Switzerland
ID NLM: 101555929
Informations de publication
Date de publication:
04 Aug 2023
04 Aug 2023
Historique:
received:
02
06
2023
revised:
20
07
2023
accepted:
24
07
2023
medline:
12
8
2023
pubmed:
12
8
2023
entrez:
12
8
2023
Statut:
epublish
Résumé
Enhancing the design of bone screw head sockets to prevent stripping and improve the torque required for smooth unscrewing is a significant challenge in orthopedic applications. This research aims to establish a quantitative methodology by integrating mechanical testing with finite element (FE) simulations to determine a safe limitation depth for the screwdriver when engaging with the hexagonal socket, thus avoiding stripped screw heads. A FE model was developed to investigate the biomechanical responses of the screw head design. Five custom-made hexagonal sockets were manufactured, and single load torsional tests were conducted to assess the mechanical performance of the screws and drivers. The results from the mechanical tests were compared with the FE simulations, demonstrating a close agreement and confirming the model's validity. Furthermore, additional FE models were created to study the impact of manufacturing tolerances on the socket width and screwdriver width. The findings revealed that the maximum torque to failure for the four designs was lower than the margins specified in ISO 6475. Additionally, increasing the depth of the screwdriver led to higher maximum torque values. This research suggests that the technique of screw insertion, specifically the depth of the driver tool within the screw socket, holds greater importance in preventing stripped screw heads than the design and manufacturing width of the bone screw's hexagonal socket and screwdriver. This confirms the importance of screwdriver engagement inside the bone screw socket to prevent stripped screw heads and sheds light on the added value of maximum torque prediction for future design modifications.
Identifiants
pubmed: 37570173
pii: ma16155470
doi: 10.3390/ma16155470
pmc: PMC10419446
pii:
doi:
Types de publication
Journal Article
Langues
eng
Subventions
Organisme : Khalifa University of Science and Technology
ID : HEIC
Références
Eur J Trauma Emerg Surg. 2013 Aug;39(4):339-44
pubmed: 26815393
J Orthop Surg Res. 2016 Oct 17;11(1):118
pubmed: 27751170
J Orthop Trauma. 2012 Jun;26(6):e51-3
pubmed: 22048181
Clin Orthop Relat Res. 2002 Nov;(404):368-72
pubmed: 12439282
J Biomed Eng. 1990 Nov;12(6):457-62
pubmed: 2266740
Med Eng Phys. 2015 Dec;37(12):1174-9
pubmed: 26521645
Materials (Basel). 2019 Jun 06;12(11):
pubmed: 31174249
EFORT Open Rev. 2020 Jan 29;5(1):26-36
pubmed: 32071771
Injury. 2011 Nov;42(11):1377-9
pubmed: 21232740
Can J Surg. 2016 Aug;59(4):281-6
pubmed: 27240129
J Bone Joint Surg Br. 2008 Dec;90(12):1608-16
pubmed: 19043133
Comput Methods Biomech Biomed Engin. 2022 Jan;25(1):97-110
pubmed: 34459294
Geriatr Orthop Surg Rehabil. 2011 May;2(3):86-9
pubmed: 23569675
J Orthop Trauma. 2010 Jun;24(6):369-73
pubmed: 20502220
Vet Comp Orthop Traumatol. 2022 Sep;35(5):339-346
pubmed: 35839838
J Prosthet Dent. 2022 Nov 7;:
pubmed: 36357194
Eur J Trauma Emerg Surg. 2013 Apr;39(2):159-62
pubmed: 26815073
J Orthop Surg Res. 2021 Oct 26;16(1):642
pubmed: 34702320
Sci Rep. 2021 Jun 15;11(1):12510
pubmed: 34131183
J Orthop Res. 2007 Aug;25(8):1115-20
pubmed: 17444509
Injury. 2018 Mar;49(3):585-592
pubmed: 29422293
Saudi Med J. 2016 Apr;37(4):348-53
pubmed: 27052276
Clin Biomech (Bristol, Avon). 2020 Dec;80:105201
pubmed: 33158573