Impact of the hybrid emergency department on resuscitation strategies and outcomes in ventricular fibrillation.

Cardiac arrest ECPR Hybrid emergency room Mortality Ventricular fibrillation

Journal

The American journal of emergency medicine
ISSN: 1532-8171
Titre abrégé: Am J Emerg Med
Pays: United States
ID NLM: 8309942

Informations de publication

Date de publication:
Nov 2023
Historique:
received: 21 02 2023
revised: 06 07 2023
accepted: 15 07 2023
pubmed: 14 8 2023
medline: 14 8 2023
entrez: 13 8 2023
Statut: ppublish

Résumé

The Hybrid emergency room (ER) is a novel resuscitation room that includes a whole-body computed tomography scanner and angiography system, which enables physicians to seamlessly conduct resuscitation, diagnosis and therapeutic interventions without patient transfer. This study aimed to assess the impact of the Hybrid ER on mortality in patients with ventricular fibrillation cardiac arrest. This was a retrospective cohort study conducted in a tertiary hospital in Japan. We consecutively included adult cardiac arrest patients who were transferred to the emergency departments from January 2007 to May 2020, and were confirmed to be in ventricular fibrillation within 10 min from patient arrival. The study population was divided into two groups: the conventional group (from January 2007 to July 2011) and the Hybrid ER group (from August 2011 to May 2020). The primary endpoint of this study was defined as all-cause in-hospital death. Secondary endpoints included the frequency of extracorporeal cardiopulmonary resuscitation (ECPR) and percutaneous coronary intervention (PCI), and door-to-balloon time and door-to-ECPR time. We included 115 patients in the conventional group and 185 patients in the Hybrid ER group. In-hospital mortality was significantly decreased in the Hybrid ER group (adjusted hazard ratio, 0.79; 95% confidence interval 0.64, 0.97; p = 0.026). Door-to-ECPR time was significantly shorter in the Hybrid ER group (p < 0.001, Gehan-Breslow-Wilcoxon test), as was door-to-balloon time in this group (p = 0.004, Gehan-Breslow-Wilcoxon test). In interrupted time-series analyses, it was visually recognized that the ratio of patients who received ECPR and PCI increased, and door-to-ECPR time and door-to-balloon time were shortened from 2011 to 2012 (before and after installation of the Hybrid ER). Installation of the Hybrid ER was associated with a reduced time to ECPR and PCI and with a possible improvement in survival in patients with ventricular fibrillation cardiac arrest.

Sections du résumé

BACKGROUND BACKGROUND
The Hybrid emergency room (ER) is a novel resuscitation room that includes a whole-body computed tomography scanner and angiography system, which enables physicians to seamlessly conduct resuscitation, diagnosis and therapeutic interventions without patient transfer. This study aimed to assess the impact of the Hybrid ER on mortality in patients with ventricular fibrillation cardiac arrest.
METHODS METHODS
This was a retrospective cohort study conducted in a tertiary hospital in Japan. We consecutively included adult cardiac arrest patients who were transferred to the emergency departments from January 2007 to May 2020, and were confirmed to be in ventricular fibrillation within 10 min from patient arrival. The study population was divided into two groups: the conventional group (from January 2007 to July 2011) and the Hybrid ER group (from August 2011 to May 2020). The primary endpoint of this study was defined as all-cause in-hospital death. Secondary endpoints included the frequency of extracorporeal cardiopulmonary resuscitation (ECPR) and percutaneous coronary intervention (PCI), and door-to-balloon time and door-to-ECPR time.
RESULTS RESULTS
We included 115 patients in the conventional group and 185 patients in the Hybrid ER group. In-hospital mortality was significantly decreased in the Hybrid ER group (adjusted hazard ratio, 0.79; 95% confidence interval 0.64, 0.97; p = 0.026). Door-to-ECPR time was significantly shorter in the Hybrid ER group (p < 0.001, Gehan-Breslow-Wilcoxon test), as was door-to-balloon time in this group (p = 0.004, Gehan-Breslow-Wilcoxon test). In interrupted time-series analyses, it was visually recognized that the ratio of patients who received ECPR and PCI increased, and door-to-ECPR time and door-to-balloon time were shortened from 2011 to 2012 (before and after installation of the Hybrid ER).
CONCLUSION CONCLUSIONS
Installation of the Hybrid ER was associated with a reduced time to ECPR and PCI and with a possible improvement in survival in patients with ventricular fibrillation cardiac arrest.

Identifiants

pubmed: 37573663
pii: S0735-6757(23)00383-2
doi: 10.1016/j.ajem.2023.07.031
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

20-26

Informations de copyright

Copyright © 2023 Elsevier Inc. All rights reserved.

Déclaration de conflit d'intérêts

Declaration of Competing Interest None.

Auteurs

Chikai Mitsuhara (C)

Division of Trauma and Surgical Critical Care, Osaka General Medical Center, 3-1-56 Bandai-Higashi, Sumiyoshi, Osaka 558-8558, Japan; Department of Traumatology and Acute Critical Medicine, Osaka University Graduate School of Medicine, 2-15 Yamadaoka, Suita, Osaka 565-0871, Japan.

Yutaka Umemura (Y)

Division of Trauma and Surgical Critical Care, Osaka General Medical Center, 3-1-56 Bandai-Higashi, Sumiyoshi, Osaka 558-8558, Japan; Department of Traumatology and Acute Critical Medicine, Osaka University Graduate School of Medicine, 2-15 Yamadaoka, Suita, Osaka 565-0871, Japan. Electronic address: plum00022@gmail.com.

Kazuma Yamakawa (K)

Department of Emergency Medicine, Osaka Medical and Pharmaceutical University, 2-7 Daigaku-machi, Takatsuki, Osaka 569-8686, Japan. Electronic address: kazuma.yamakawa@ompu.ac.jp.

Atsushi Watanabe (A)

Division of Trauma and Surgical Critical Care, Osaka General Medical Center, 3-1-56 Bandai-Higashi, Sumiyoshi, Osaka 558-8558, Japan.

Hiroshi Ogura (H)

Department of Traumatology and Acute Critical Medicine, Osaka University Graduate School of Medicine, 2-15 Yamadaoka, Suita, Osaka 565-0871, Japan. Electronic address: ogura@hp-emerg.med.osaka-u.ac.jp.

Satoshi Fujimi (S)

Division of Trauma and Surgical Critical Care, Osaka General Medical Center, 3-1-56 Bandai-Higashi, Sumiyoshi, Osaka 558-8558, Japan. Electronic address: sfujimi40@nifty.com.

Classifications MeSH