A micro-flow, high-pH, reversed-phase peptide fractionation and collection system for targeted and in-depth proteomics of low-abundance proteins in limiting samples.
CDK4/6 inhibitors
Cell-cycle
Global proteomics
High-pH reversed phase liquid chromatography
Micro-flow high-pH reversed-phase LC system for peptide fractionation and collection
Multiple reaction monitoring (MRM)
Parallel reaction monitoring (PRM)
Peptide fractionation
Proteomics
Targeted proteomics
Two-dimensional peptide separation
Journal
MethodsX
ISSN: 2215-0161
Titre abrégé: MethodsX
Pays: Netherlands
ID NLM: 101639829
Informations de publication
Date de publication:
Dec 2023
Dec 2023
Historique:
received:
25
04
2023
accepted:
29
07
2023
medline:
14
8
2023
pubmed:
14
8
2023
entrez:
14
8
2023
Statut:
epublish
Résumé
We present a method and a simple system for high-pH RP-LC peptide fractionation of small sample amounts (30-60 µg), at micro-flow rates with micro-liter fraction collection using ammonium bicarbonate as an optimized buffer for system stability and robustness. The method is applicable to targeted mass spectrometry approaches and to in-depth proteomic studies where the amount of sample is limited. Using targeted proteomics with peptide standards, we present the method's analytical parameters, and potential in increasing the detection of low-abundance proteins that are difficult to quantify with direct targeted or global LC-MS analyses. This fractionation system increased peptide signals by up to 18-fold, while maintaining high quantitative precision, with high fractionation reproducibility across varied sample sets. In real applications, it increased the detection of targeted endogenous peptides by two-fold in a 25 cell-cycle-control protein panel, and in-depth MS analyses of nuclear extracts, it allowed the detection of up to 8,896 proteins with 138,417 peptides in 24-concatenated fractions compared to 3,344 proteins with 23,093 peptides without fractionation. In a relevant biological problem of CDK4/6-inhibitors and breast cancer, the method reproduced known information and revealed novel insights, highlighting that it can be successfully applied in studies involving low-abundance proteins and limited samples. •Tested nine high-pH buffer/solvent systems to obtain a robust, effective, and reproducible micro-flow fractionation method which was devoid of commonly encountered LC clogging/pressure issues after months of use.•Peptide enrichment method to improve detection and quantitation of low-abundance proteins in targeted and in-depth proteomic studies.•Can be applied to diverse protein samples where the available amount is limited.
Identifiants
pubmed: 37577163
doi: 10.1016/j.mex.2023.102306
pii: S2215-0161(23)00303-5
pmc: PMC10413349
doi:
Types de publication
Journal Article
Langues
eng
Pagination
102306Informations de copyright
© 2023 The Authors. Published by Elsevier B.V.
Déclaration de conflit d'intérêts
The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Références
Clin Cancer Res. 2018 Jun 1;24(11):2517-2529
pubmed: 29581135
Cancer Cell. 2018 Dec 10;34(6):893-905.e8
pubmed: 30537512
Oncogene. 2017 Apr 20;36(16):2255-2264
pubmed: 27748766
Pharmacol Res. 2020 Jun;156:104686
pubmed: 32068118
Front Bioeng Biotechnol. 2015 Apr 01;3:44
pubmed: 25883932
Nucleic Acids Res. 2016 Jul 8;44(W1):W147-53
pubmed: 27190236
Front Plant Sci. 2021 Mar 10;12:635550
pubmed: 33777071
Expert Rev Proteomics. 2012 Apr;9(2):129-34
pubmed: 22462785
Anal Chem. 2016 Jan 5;88(1):746-53
pubmed: 26606514
Clin Cancer Res. 2015 Jul 1;21(13):2905-10
pubmed: 25941111
Proteomes. 2022 Jan 13;10(1):
pubmed: 35076613
Anal Chem. 2020 Mar 3;92(5):3904-3912
pubmed: 32030975
Anal Chem. 2019 Aug 6;91(15):9707-9715
pubmed: 31241912
Nat Commun. 2021 Sep 10;12(1):5386
pubmed: 34508104
Mol Cell Proteomics. 2017 Apr;16(4):694-705
pubmed: 28126900
Anal Chem. 2018 Apr 17;90(8):5381-5389
pubmed: 29582996