Ultrahigh-field MRI: where it really makes a difference.
Ultrahochfeld-MRT: wo es wirklich einen Unterschied macht.
7 Tesla
Multiple sclerosis
Sodium imaging
Spectroscopic imaging
Susceptibility weighted imaging
Journal
Radiologie (Heidelberg, Germany)
ISSN: 2731-7056
Titre abrégé: Radiologie (Heidelb)
Pays: Germany
ID NLM: 9918384887306676
Informations de publication
Date de publication:
16 Aug 2023
16 Aug 2023
Historique:
accepted:
30
06
2023
medline:
16
8
2023
pubmed:
16
8
2023
entrez:
16
8
2023
Statut:
aheadofprint
Résumé
Currently, two major magnetic resonance (MR) vendors provide commercial 7‑T scanners that are approved by the Food and Drug Administration (FDA) for clinical application. There is growing interest in ultrahigh-field MRI because of the improved clinical results in terms of morphological detail, as well as functional and metabolic imaging capabilities. The 7‑T systems benefit from a higher signal-to-noise ratio, which scales supralinearly with field strength, a supralinear increase in the blood oxygenation level dependent (BOLD) contrast for functional MRI and susceptibility weighted imaging (SWI), and the chemical shift increases linearly with field strength with consequently higher spectral resolution. In multiple sclerosis (MS), 7‑T imaging enables visualization of cortical lesions, the central vein sign, and paramagnetic rim lesions, which may be beneficial for the differential diagnosis between MS and other neuroinflammatory diseases in challenging and inconclusive clinical presentations and are seen as promising biomarkers for prognosis and treatment monitoring. The recent development of high-resolution proton MR spectroscopic imaging in clinically reasonable scan times has provided new insights into tumor metabolism and tumor grading as well as into early metabolic changes that may precede inflammatory processes in MS. This technique also improves the detection of epileptogenic foci in the brain. Multi-nuclear clinical applications, such as sodium imaging, have shown great potential for the evaluation of repair tissue quality after cartilage transplantation and in the monitoring of newly developed cartilage regenerative drugs for osteoarthritis. For special clinical applications, such as SWI in MS, MR spectroscopic imaging in tumors, MS and epilepsy, and sodium imaging in cartilage repair, 7T may become a new standard. HINTERGRUND: Derzeit bieten 2 Hersteller von Geräten für die Magnetresonanztomographie (MRT) kommerzielle 7‑T-MRT-Geräte mit Zulassung der US-amerikanischen Food and Drug Administration (FDA) für die klinische Anwendung an. Es besteht ein zunehmendes Interesse an Ultrahochfeld-MRT sowohl aufgrund verbesserter klinischer Ergebnisse bei morphologischen Details als auch bei den funktionellen und metabolischen bildgebenden Möglichkeiten. Vorteile der 7‑T-Technik sind ein höheres Signal-zu-Rausch-Verhältnis, das von 3 T auf 7 T sogar supralinear zunimmt, eine ebenfalls supralineare Zunahme des Blood-Oxygenation-Level-Dependent(BOLD)-Kontrasts für funktionelle MRT und die suszeptibilitätsgewichtete Bildgebung sowie die lineare Zunahme des Chemical Shift mit konsekutiv höherer spektraler Auflösung. Bei multipler Sklerose (MS) ermöglicht die 7‑T-Technik die Visualisierung von kortikalen Läsionen, das zentrale Venenzeichen und den Nachweis von paramagnetischen Randsaumläsionen, die für die Differenzialdiagnose zwischen MS und anderen neuroinflammatorischen Erkrankungen bei schwierigen, unklaren klinischen Symptomen von Vorteil sein können sowie als vielversprechende Biomarker für Prognose- und Therapiemonitoring gesehen werden. Die kürzlich entwickelte hochauflösende Protonen-MR-Spektroskopie in klinisch noch vertretbaren Untersuchungszeiten liefert neue Einsichten in den Tumorstoffwechsel und das Grading von Tumoren, in frühe metabolische Veränderungen, die entzündlichen Prozessen bei MS vorausgehen können, und verbessert den Nachweis von epileptogenen Herden im Gehirn. Klinische Multi-Kern-Anwendungen, wie beispielsweise die Natriumbildgebung, weisen ein hohes Potenzial für die Evaluation der Qualität des Ersatzgewebes nach Knorpeltransplantationen und im Monitoring von neu entwickelten knorpelregenerativen Medikamenten zur Behandlung der Gelenkarthrose auf. Für besondere klinische Anwendungen wie z. B. SWI bei MS, MR-spektroskopische Bildgebung beim Hirntumorgrading und Monitoring unter Therapie oder beim Nachweis von epileptischen Foci, und der Anwendung von Multikern-MR wie die Natriumbildgebung zur Qualitätsbeurteilung von Knorpelersatztherapien, hat 7T das Potenzial ein neuer bildgebender Standard zu werden.
Sections du résumé
BACKGROUND
BACKGROUND
Currently, two major magnetic resonance (MR) vendors provide commercial 7‑T scanners that are approved by the Food and Drug Administration (FDA) for clinical application. There is growing interest in ultrahigh-field MRI because of the improved clinical results in terms of morphological detail, as well as functional and metabolic imaging capabilities.
MATERIALS AND METHODS
METHODS
The 7‑T systems benefit from a higher signal-to-noise ratio, which scales supralinearly with field strength, a supralinear increase in the blood oxygenation level dependent (BOLD) contrast for functional MRI and susceptibility weighted imaging (SWI), and the chemical shift increases linearly with field strength with consequently higher spectral resolution.
RESULTS
RESULTS
In multiple sclerosis (MS), 7‑T imaging enables visualization of cortical lesions, the central vein sign, and paramagnetic rim lesions, which may be beneficial for the differential diagnosis between MS and other neuroinflammatory diseases in challenging and inconclusive clinical presentations and are seen as promising biomarkers for prognosis and treatment monitoring. The recent development of high-resolution proton MR spectroscopic imaging in clinically reasonable scan times has provided new insights into tumor metabolism and tumor grading as well as into early metabolic changes that may precede inflammatory processes in MS. This technique also improves the detection of epileptogenic foci in the brain. Multi-nuclear clinical applications, such as sodium imaging, have shown great potential for the evaluation of repair tissue quality after cartilage transplantation and in the monitoring of newly developed cartilage regenerative drugs for osteoarthritis.
CONCLUSION
CONCLUSIONS
For special clinical applications, such as SWI in MS, MR spectroscopic imaging in tumors, MS and epilepsy, and sodium imaging in cartilage repair, 7T may become a new standard.
ZUSAMMENFASSUNG
UNASSIGNED
HINTERGRUND: Derzeit bieten 2 Hersteller von Geräten für die Magnetresonanztomographie (MRT) kommerzielle 7‑T-MRT-Geräte mit Zulassung der US-amerikanischen Food and Drug Administration (FDA) für die klinische Anwendung an. Es besteht ein zunehmendes Interesse an Ultrahochfeld-MRT sowohl aufgrund verbesserter klinischer Ergebnisse bei morphologischen Details als auch bei den funktionellen und metabolischen bildgebenden Möglichkeiten.
MATERIAL UND METHODEN
METHODS
Vorteile der 7‑T-Technik sind ein höheres Signal-zu-Rausch-Verhältnis, das von 3 T auf 7 T sogar supralinear zunimmt, eine ebenfalls supralineare Zunahme des Blood-Oxygenation-Level-Dependent(BOLD)-Kontrasts für funktionelle MRT und die suszeptibilitätsgewichtete Bildgebung sowie die lineare Zunahme des Chemical Shift mit konsekutiv höherer spektraler Auflösung.
ERGEBNISSE
UNASSIGNED
Bei multipler Sklerose (MS) ermöglicht die 7‑T-Technik die Visualisierung von kortikalen Läsionen, das zentrale Venenzeichen und den Nachweis von paramagnetischen Randsaumläsionen, die für die Differenzialdiagnose zwischen MS und anderen neuroinflammatorischen Erkrankungen bei schwierigen, unklaren klinischen Symptomen von Vorteil sein können sowie als vielversprechende Biomarker für Prognose- und Therapiemonitoring gesehen werden. Die kürzlich entwickelte hochauflösende Protonen-MR-Spektroskopie in klinisch noch vertretbaren Untersuchungszeiten liefert neue Einsichten in den Tumorstoffwechsel und das Grading von Tumoren, in frühe metabolische Veränderungen, die entzündlichen Prozessen bei MS vorausgehen können, und verbessert den Nachweis von epileptogenen Herden im Gehirn. Klinische Multi-Kern-Anwendungen, wie beispielsweise die Natriumbildgebung, weisen ein hohes Potenzial für die Evaluation der Qualität des Ersatzgewebes nach Knorpeltransplantationen und im Monitoring von neu entwickelten knorpelregenerativen Medikamenten zur Behandlung der Gelenkarthrose auf.
SCHLUSSFOLGERUNG
UNASSIGNED
Für besondere klinische Anwendungen wie z. B. SWI bei MS, MR-spektroskopische Bildgebung beim Hirntumorgrading und Monitoring unter Therapie oder beim Nachweis von epileptischen Foci, und der Anwendung von Multikern-MR wie die Natriumbildgebung zur Qualitätsbeurteilung von Knorpelersatztherapien, hat 7T das Potenzial ein neuer bildgebender Standard zu werden.
Autres résumés
Type: Publisher
(ger)
HINTERGRUND: Derzeit bieten 2 Hersteller von Geräten für die Magnetresonanztomographie (MRT) kommerzielle 7‑T-MRT-Geräte mit Zulassung der US-amerikanischen Food and Drug Administration (FDA) für die klinische Anwendung an. Es besteht ein zunehmendes Interesse an Ultrahochfeld-MRT sowohl aufgrund verbesserter klinischer Ergebnisse bei morphologischen Details als auch bei den funktionellen und metabolischen bildgebenden Möglichkeiten.
Identifiants
pubmed: 37584681
doi: 10.1007/s00117-023-01184-x
pii: 10.1007/s00117-023-01184-x
doi:
Types de publication
Journal Article
Review
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
© 2023. The Author(s).
Références
Hangel G, Niess E, Lazen P, Bednarik P, Bogner W, Strasser B (2022) Emerging methods and applications of ultra-high field MR spectroscopic imaging in the human brain. Anal Biochem 638:114479. https://doi.org/10.1016/j.ab.2021.114479
doi: 10.1016/j.ab.2021.114479
pubmed: 34838516
Hangel G, Cadrien C, Lazen P et al (2020) High-resolution metabolic imaging of high-grade gliomas using 7T-CRT-FID-MRSI. Neuroimage Clin 28:102433. https://doi.org/10.1016/j.nicl.2020.102433
doi: 10.1016/j.nicl.2020.102433
pubmed: 32977210
pmcid: 7511769
Weng G, Radojewski P, Sheriff S et al (2022) SLOW: a novel spectral editing method for whole-brain MRSI at ultra high magnetic field. Magn Reson Med 88(1):53–70. https://doi.org/10.1002/mrm.29220
doi: 10.1002/mrm.29220
pubmed: 35344608
pmcid: 9212787
Hingerl L, Strasser B, Moser P et al (2020) Clinical high-resolution 3D-MR spectroscopic imaging of the human brain at 7 T. Invest Radiol 55(4):239–248. https://doi.org/10.1097/RLI.0000000000000626
doi: 10.1097/RLI.0000000000000626
pubmed: 31855587
Hangel G, Lazen P, Sharma S et al (2022) 7T HR FID-MRSI compared to amino acid PET: glutamine and Glycine as promising biomarkers in brain tumors. Cancers. https://doi.org/10.3390/cancers14092163
doi: 10.3390/cancers14092163
pubmed: 35565293
pmcid: 9101868
Pan JW, Duckrow RB, Gerrard J et al (2013) 7T MR spectroscopic imaging in the localization of surgical epilepsy. Epilepsia 54(9):1668–1678. https://doi.org/10.1111/epi.12322
doi: 10.1111/epi.12322
pubmed: 23895497
pmcid: 3938332
van Veenendaal TM, Backes WH, Tse DHY et al (2018) High field imaging of large-scale neurotransmitter networks: proof of concept and initial application to epilepsy. Neuroimage Clin 19:47–55. https://doi.org/10.1016/j.nicl.2018.04.006
doi: 10.1016/j.nicl.2018.04.006
pubmed: 30035001
pmcid: 6051471
Heckova E, Strasser B, Hangel GJ et al (2019) 7 T magnetic resonance spectroscopic imaging in multiple sclerosis: how does spatial resolution affect the detectability of metabolic changes in brain lesions? Invest Radiol 54(4):247–254. https://doi.org/10.1097/RLI.0000000000000531
doi: 10.1097/RLI.0000000000000531
pubmed: 30433892
pmcid: 7612616
Heckova E, Dal-Bianco A, Strasser B et al (2022) Extensive brain pathologic alterations detected with 7.0‑T MR spectroscopic imaging associated with disability in multiple sclerosis. Radiology 303(1):141–150. https://doi.org/10.1148/radiol.210614
doi: 10.1148/radiol.210614
pubmed: 34981978
Shmueli K, de Zwart JA, van Gelderen P, Li TQ, Dodd SJ, Duyn JH (2009) Magnetic susceptibility mapping of brain tissue in vivo using MRI phase data. Magn Reson Med 62(6):1510–1522. https://doi.org/10.1002/mrm.22135
doi: 10.1002/mrm.22135
pubmed: 19859937
pmcid: 4275127
Reichenbach JR, Barth M, Haacke EM, Klarhofer M, Kaiser WA, Moser E (2000) High-resolution MR venography at 3.0 Tesla. J Comput Assist Tomogr 24(6):949–957. https://doi.org/10.1097/00004728-200011000-00023
doi: 10.1097/00004728-200011000-00023
pubmed: 11105717
Deistung A, Rauscher A, Sedlacik J, Stadler J, Witoszynskyj S, Reichenbach JR (2008) Susceptibility weighted imaging at ultra high magnetic field strengths: theoretical considerations and experimental results. Magn Reson Med 60(5):1155–1168. https://doi.org/10.1002/mrm.21754
doi: 10.1002/mrm.21754
pubmed: 18956467
Preziosa P, Rocca MA, Filippi M (2021) Central vein sign and iron rim in multiple sclerosis: ready for clinical use? Curr Opin Neurol 34(4):505–513. https://doi.org/10.1097/WCO.0000000000000946
doi: 10.1097/WCO.0000000000000946
pubmed: 33928930
Dal-Bianco A, Grabner G, Kronnerwetter C et al (2021) Long-term evolution of multiple sclerosis iron rim lesions in 7 T MRI. Brain 144(3):833–847. https://doi.org/10.1093/brain/awaa436
doi: 10.1093/brain/awaa436
pubmed: 33484118
Hametner S, Dal Bianco A, Trattnig S, Lassmann H (2018) Iron related changes in MS lesions and their validity to characterize MS lesion types and dynamics with Ultra-high field magnetic resonance imaging. Brain Pathol 28(5):743–749. https://doi.org/10.1111/bpa.12643
doi: 10.1111/bpa.12643
pubmed: 30020556
pmcid: 8028547
Bamm VV, Henein MEL, Sproul SLJ, Lanthier DK, Harauz G (2017) Potential role of ferric hemoglobin in MS pathogenesis: Effects of oxidative stress and extracellular methemoglobin or its degradation products on myelin components. Free Radic Biol Med 112:494–503. https://doi.org/10.1016/j.freeradbiomed.2017.08.022
doi: 10.1016/j.freeradbiomed.2017.08.022
pubmed: 28863941
Wittayer M, Weber CE, Kramer J et al (2023) Exploring (peri‑) lesional and structural connectivity tissue damage through T1/T2-weighted ratio in iron rim multiple sclerosis lesions. Magn Reson Imaging 95:12–18. https://doi.org/10.1016/j.mri.2022.10.009
doi: 10.1016/j.mri.2022.10.009
pubmed: 36270415
Absinta M, Sati P, Schindler M et al (2016) Persistent 7‑tesla phase rim predicts poor outcome in new multiple sclerosis patient lesions. J Clin Invest 126(7):2597–2609. https://doi.org/10.1172/JCI86198
doi: 10.1172/JCI86198
pubmed: 27270171
pmcid: 4922708
Castellaro M, Tamanti A, Pisani AI, Pizzini FB, Crescenzo F, Calabrese M (2020) The use of the central vein sign in the diagnosis of multiple sclerosis: a systematic review and meta-analysis. Diagnostics. https://doi.org/10.3390/diagnostics10121025
doi: 10.3390/diagnostics10121025
pubmed: 33260401
pmcid: 7760678
Dal-Bianco A, Grabner G, Kronnerwetter C et al (2017) Slow expansion of multiple sclerosis iron rim lesions: pathology and 7 T magnetic resonance imaging. Acta Neuropathol 133(1):25–42. https://doi.org/10.1007/s00401-016-1636-z
doi: 10.1007/s00401-016-1636-z
pubmed: 27796537
Tallantyre EC, Morgan PS, Dixon JE et al (2009) A comparison of 3T and 7T in the detection of small parenchymal veins within MS lesions. Invest Radiol 44(9):491–494. https://doi.org/10.1097/RLI.0b013e3181b4c144
doi: 10.1097/RLI.0b013e3181b4c144
pubmed: 19652606
Wuerfel J, Sinnecker T, Ringelstein EB et al (2012) Lesion morphology at 7 Tesla MRI differentiates Susac syndrome from multiple sclerosis. Mult Scler 18(11):1592–1599. https://doi.org/10.1177/1352458512441270
doi: 10.1177/1352458512441270
pubmed: 22711711
Jang J, Nam Y, Choi Y et al (2020) Paramagnetic rims in multiple sclerosis and neuromyelitis optica spectrum disorder: a quantitative susceptibility mapping study with 3‑T MRI. J Clin Neurol 16(4):562–572. https://doi.org/10.3988/jcn.2020.16.4.562
doi: 10.3988/jcn.2020.16.4.562
pubmed: 33029961
pmcid: 7542003
Maggi P, Sati P, Nair G et al (2020) Paramagnetic rim lesions are specific to multiple sclerosis: an international multicenter 3T MRI study. Ann Neurol 88(5):1034–1042. https://doi.org/10.1002/ana.25877
doi: 10.1002/ana.25877
pubmed: 32799417
pmcid: 9943711
Kilsdonk ID, Jonkman LE, Klaver R et al (2016) Increased cortical grey matter lesion detection in multiple sclerosis with 7 T MRI: a post-mortem verification study. Brain 139(Pt 5):1472–1481. https://doi.org/10.1093/brain/aww037
doi: 10.1093/brain/aww037
pubmed: 26956422
Peterson L, Minas T, Brittberg M, Lindahl A (2003) Treatment of osteochondritis dissecans of the knee with autologous chondrocyte transplantation: results at two to ten years. J Bone Joint Surg Am 85-A(Suppl 2):17–24. https://doi.org/10.2106/00004623-200300002-00003
doi: 10.2106/00004623-200300002-00003
Roberts S, McCall IW, Darby AJ et al (2003) Autologous chondrocyte implantation for cartilage repair: monitoring its success by magnetic resonance imaging and histology. Arthritis Res Ther 5(1):R60–R73
doi: 10.1186/ar613
pubmed: 12716454
Knutsen G, Engebretsen L, Ludvigsen TC et al (2004) Autologous chondrocyte implantation compared with microfracture in the knee—A randomized trial. J Bone Joint Surg Am 86A(3):455–464
doi: 10.2106/00004623-200403000-00001
Bashir A, Gray ML, Burstein D (1996) Gd-DTPA2- as a measure of cartilage degradation. Magn Reson Med 36(5):665–673. https://doi.org/10.1002/mrm.1910360504
doi: 10.1002/mrm.1910360504
pubmed: 8916016
Maroudas A, Muir H, Wingham J (1969) The correlation of fixed negative charge with glycosaminoglycan content of human articular cartilage. Biochim Biophys Acta 177(3):492–500
doi: 10.1016/0304-4165(69)90311-0
pubmed: 4239606
Trattnig S, Welsch GH, Juras V et al (2010) Na-23 MR imaging at 7 T after knee matrix-associated autologous chondrocyte transplantation: preliminary results. Radiology 257(1):175–184
doi: 10.1148/radiol.10100279
pubmed: 20713608
Zbyn S, Stelzeneder D, Welsch GH et al (2012) Evaluation of native hyaline cartilage and repair tissue after two cartilage repair surgery techniques with Na-23 MR imaging at 7 T: initial experience. Osteoarthr Cartil 20(8):837–845
doi: 10.1016/j.joca.2012.04.020
Madelin G, Lee JS, Inati S, Jerschow A, Regatte RR (2010) Sodium inversion recovery MRI of the knee joint in vivo at 7T. J Magn Reson 207(1):42–52
doi: 10.1016/j.jmr.2010.08.003
pubmed: 20813569
pmcid: 2989635