Quantifying microcyte and macrocyte percentages in archived red blood cell volume histogram images.

Gauss' area formula hemochromatosis hemoglobin iron deficiency mean corpuscular hemoglobin mean corpuscular volume

Journal

International journal of laboratory hematology
ISSN: 1751-553X
Titre abrégé: Int J Lab Hematol
Pays: England
ID NLM: 101300213

Informations de publication

Date de publication:
Dec 2023
Historique:
received: 27 05 2023
accepted: 29 07 2023
medline: 17 11 2023
pubmed: 25 8 2023
entrez: 25 8 2023
Statut: ppublish

Résumé

We sought to quantify percentages of microcytes and macrocytes in archived automated hematology analyzer (AHA) red blood cell (RBC) volume histogram images. In preliminary studies, we demonstrated that an on-line application of Gauss' area formula (SketchAndCalc™) measured percentage areas of 20 segments under a computer-generated normal distribution curve (-3.0 standard deviations [SD] to +3.0 SD) with accuracy and precision (Pearson's correlation of measured areas with corresponding theoretical areas r [20] = 0.9962 [p < 0.0001]). Thus, we used SketchAndCalc™ to quantify percentages of microcytes (50-80 fL) and macrocytes (110-200 fL) in archived AHA histogram images in women with previously untreated iron-deficiency anemia (IDA) and previously untreated hemochromatosis. Median microcyte percentages in 13 women with IDA and 13 women with hemochromatosis were 63.6% (range 13.5-76.8) and 6.7% (range 3.4-24.8), respectively (p < 0.0001). Mean macrocyte percentages in women with IDA and hemochromatosis were 8.8% ± 6.1 SD and 33.8% ± 11.7 SD, respectively (p < 0.0001). Spearman's correlations of microcyte percentages with macrocyte percentages, mean corpuscular volume, and mean corpuscular hemoglobin in 26 women were r This method of quantifying microcyte and macrocyte percentages could enable other studies of RBC volume subpopulations in archived AHA histogram images.

Identifiants

pubmed: 37622672
doi: 10.1111/ijlh.14147
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

875-880

Informations de copyright

© 2023 John Wiley & Sons Ltd.

Références

Bruegel M, Nagel D, Funk M, Fuhrmann P, Zander J, Teupser D. Comparison of five automated hematology analyzers in a university hospital setting: Abbott Cell-Dyn Sapphire, Beckman Coulter DxH 800, Siemens Advia 2120i, Sysmex XE-5000, and Sysmex XN-2000. Clin Chem Lab Med. 2015;53:1057-1071.
CLSI: Document H15-A3. Reference and Selected Procedures for the Quantitative Determination of Hemoglobin in Blood: Approved Standard. 3rd ed. Ft. ed. Clinical and Laboratory Standards Institute; 2000.
Smock KJ. Examination of blood and bone marrow. In: Greer JP, Rodgers GM, Glader B, et al., eds. Wintrobe's Clinical Hematology. 14th ed. Wolters Kluwer; 2019:1-16.
Hill VL, Simpson VZ, Higgins JM, et al. Evaluation of the performance of the Sysmex XT-2000i Hematology Analyzer with whole bloods stored at room temperature. Lab Med. 2009;40:709-718.
Constantino BT. The red cell histogram and the dimorphic red cell population. Lab Med. 2011;42:300-308.
Thomas ETA, Bhagya S, Majeed A. Clinical utility of blood cell histogram interpretation. J Clin Diagn Res. 2017;11:OE01-OE04.
Price-Jones C. The diameters of red cells in pernicious anaemia and in anaemia following haemorrhage. J Pathol Bacteriol. 1922;25:487-504.
England JM, Ward SM, Down MC. Microcytosis, anisocytosis and the red cell indices in iron deficiency. Br J Haematol. 1976;34:589-597.
Bartels PC, Helleman PW, Soons JB. Evaluation of red blood cell size distribution histograms: the fraction of microcytes. Ann Clin Biochem. 1988;25:680-687.
Weiser MG. Erythrocyte volume distribution analysis in healthy dogs, cats, horses, and dairy cows. Am J Vet Res. 1982;43:163-166.
Urrechaga E, Borque L, Escanera JF. The role of automated measurement of RBC subpopulations in differential diagnosis of microcytic anemia and ß-thalassemia screening. Am J Clin Pathol. 2011;135:374-379.
Horne BD, Muhlestein JB, Bennett ST, et al. Extreme erythrocyte macrocytic and microcytic percentages are highly predictive of morbidity and mortality. JCI Insight. 2018;3:e120183.
Braden B. The surveyor's area formula. Coll Math J. 1986;17:326-337.
Amesty MV, Chamorro CI, Lopez-Pereira P, et al. Creation of tissue-engineered urethras for large urethral defect repair in a rabbit experimental model. Front Pediatr. 2021;9:691131.
Tiddy IC, Kaullysing D, Bailey D, et al. Outplanting of branching Acropora enhances recolonization of a fish species and protects massive corals from predation. Coral Reefs. 2021;40:1549-1561.
Singh H, Kaur J, Bala R, et al. Residual effect of defeated stripe rust resistance genes/QTLs in bread wheat against prevalent pathotypes of Puccinia striiformis f. sp. tritici. PloS One. 2022;17:e0266482.
Thompson HJ, Frisbie R, Smith H, Craig E, Milhem M, Liu V. Ultraviolet camera-aided sunscreen application in children: demonstration of efficacy and receptivity. J Am Acad Dermatol. 2022;86:1390-1392.
Barton JC, Barton JC. Measuring RBC subpopulations using archived automated hematology analyzer reports. https://figshare.com/articles/dataset/Measuring_RBC_subpopulations_using_archived_automated_hematology_analyzer_reports/22644901. Accessed April 17, 2023.
Barton JC, Barton JC, Bertoli LF. Pica associated with iron deficiency or depletion: clinical and laboratory correlates in 262 non-pregnant adult outpatients. BMC Blood Disord. 2010;10:9.
Adams PC, Reboussin DM, Barton JC, et al. Hemochromatosis and iron-overload screening in a racially diverse population. N Engl J Med. 2005;352:1769-1778.
Barton JC, Barton JC, Acton RT. OSF dataset: Observations in 180 referred Alabama hemochromatosis probands with HFE p.C282Y homozygosity and HLA-A typing. https://osf.io/tq8x6. Accessed November 2, 2022.
Sachse C, Henkel E. An evaluation of the cell-Dyn 1700 haematology analyser: automated cell counting and three-part leucocyte differentiation. Clin Lab Haematol. 1996;18:171-180.
Barton JC, Barton JC, Acton RT. HLA-A*03, the hemochromatosis ancestral haplotype, and phenotypes of referred hemochromatosis probands with HFE p.C282Y homozygosity. Hereditas. 2022;159:25.
SketchAndCalc™. https://www.sketchandcalc.com. Accessed November 1, 2022.
Barton JC, Bertoli LF, Rothenberg BE. Peripheral blood erythrocyte parameters in hemochromatosis: evidence for increased erythrocyte hemoglobin content. J Lab Clin Med. 2000;135:96-104.
Barton JC, Barton JC. Supplemental Figure 1. Measurement of microcyte percentage in RBC histogram of a woman with iron deficiency. https://figshare.com/articles/figure/Supplemental_Figure_1_Measurement_of_microcyte_percentage_in_RBC_histogram_of_a_woman_with_iron_deficiency_docx/22817828. Accessed April 17, 2023.
Barton JC, Barton JC. Supplemental Figure 2. Measurement of macrocyte pecentage in RBC histogram of a woman with hemochromatosis. https://figshare.com/articles/figure/Supplemental_Figure_2_Measurement_of_macrocyte_pecentage_in_RBC_histogram_of_a_woman_with_hemochromatosis_docx/22817831. Accessed April 17, 2023.
Student. The probable error of a mean. Biometrika. 1908;6:1-25.
Fowler J, Cohen L, Jarvis P. Comparing averages. Practical Statistics for Field Biology. John Wiley & Sons; 1998:165-178.
Fowler J, Cohen L, Jarvis P. Measuring correlations. Practical Statistics for Field Biology. 2nd ed. John Wiley & Sons, Ltd.; 2009:130-141.
Weiser G, O'Grady M. Erythrocyte volume distribution analysis and hematologic changes in dogs with iron deficiency anemia. Vet Pathol. 1983;20:230-241.
McLaren CE, Barton JC, Gordeuk VR, et al. Determinants and characteristics of mean corpuscular volume and hemoglobin concentration in white HFE C282Y homozygotes in the Hemochromatosis and Iron Overload Screening Study. Am J Hematol. 2007;82:898-905.
Weiss GB, Bessman JD. Spurious automated red cell values in warm autoimmune hemolytic anemia. Am J Hematol. 1984;17:433-435.
Becker M, Moritz A, Giger U. Comparative clinical study of canine and feline total blood cell count results with seven in-clinic and two commercial laboratory hematology analyzers. Vet Clin Pathol. 2008;37:373-384.
Hiraishi JS, Matsumoto HM, Irayama HH. Experimental blood cell counting on several kinds of animals with an automated hematology analyzer. Sysmex J Int. 2007;17:1-7.
Vap L, Bohn AA. Hematology of camelids. Vet Clin North Am: Exot Anim Pract. 2015;18:41-49.

Auteurs

James C Barton (JC)

Department of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, USA.
Southern Iron Disorders Center, Birmingham, Alabama, USA.

J Clayborn Barton (JC)

Southern Iron Disorders Center, Birmingham, Alabama, USA.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH