Evaluation of institutional whole-body and extremity occupational radiation doses in nuclear medicine.


Journal

Radiation protection dosimetry
ISSN: 1742-3406
Titre abrégé: Radiat Prot Dosimetry
Pays: England
ID NLM: 8109958

Informations de publication

Date de publication:
16 Nov 2023
Historique:
received: 27 02 2023
revised: 28 07 2023
accepted: 07 08 2023
pubmed: 28 8 2023
medline: 28 8 2023
entrez: 27 8 2023
Statut: ppublish

Résumé

This study evaluated nuclear medicine occupational radiation doses at Sultan Qaboos University Hospital, a 700-bed tertiary care teaching hospital in Oman. Personal effective whole-body doses, Hp(10), and extremity doses, Hp(0.07), were collected for 19 medical radiation workers over a 7-year period (2015-2021). Personal doses for four professional groups were measured using calibrated thermo-luminescence dosemeters ((LiF:Mg,Ti) TLD-100). The average, median and maximum cumulative doses were compared against the annual whole-body and extremity dose limits (20 mSv and 500 mSv y-1, respectively) and local dose investigation level (DIL; 6 mSv y-1). Personal whole-body doses (average:median:maximum) for technologists, medical physicists, nuclear medicine physicians and nurses were 1.8:1.1:7.8, 0.3:0.3:0.4, 0.1:0.1:0.2 and 0.1:0.1:0.2 mSv, respectively. Personal extremity doses for left and right hand (average and maximum doses) follow similar trends. Average annual effective whole-body and extremity doses were well below the recommended annual dose limits. The findings suggest lowering local DIL for all staff except for technologists.

Identifiants

pubmed: 37635272
pii: 7251320
doi: 10.1093/rpd/ncad235
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

2318-2327

Informations de copyright

© The Author(s) 2023. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Auteurs

Yassine Bouchareb (Y)

Sultan Qaboos University, College of Medicine and Health Sciences, Radiology and Molecular Imaging Department, PO Box 35, PC 123, Al-Khoud, Muscat, Oman.

Jihad Al-Mabsali (J)

Sultan Qaboos University, College of Medicine and Health Sciences, Radiology and Molecular Imaging Department, PO Box 35, PC 123, Al-Khoud, Muscat, Oman.

Hilal Al-Zeheimi (H)

Sultan Qaboos University, College of Medicine and Health Sciences, Radiology and Molecular Imaging Department, PO Box 35, PC 123, Al-Khoud, Muscat, Oman.

Aziza Al-Jabri (A)

Sultan Qaboos University Hospital, Radiology and Molecular Imaging Department, PO Box 38, PC 123, Al-Khoud, Muscat, Oman.

Naima Tag (N)

Sultan Qaboos University Hospital, Radiology and Molecular Imaging Department, PO Box 38, PC 123, Al-Khoud, Muscat, Oman.

Humoud Al-Dhuhli (H)

Sultan Qaboos University Hospital, Radiology and Molecular Imaging Department, PO Box 38, PC 123, Al-Khoud, Muscat, Oman.

Classifications MeSH