Quality and transparency of evidence for implantable cardiovascular medical devices assessed by the CORE-MD Consortium.

Conformité Européenne European Union Medical Device Regulation cardiovascular devices class III medical devices high-risk medical devices implantable devices

Journal

European heart journal
ISSN: 1522-9645
Titre abrégé: Eur Heart J
Pays: England
ID NLM: 8006263

Informations de publication

Date de publication:
28 Aug 2023
Historique:
received: 16 05 2023
revised: 15 08 2023
accepted: 21 08 2023
medline: 28 8 2023
pubmed: 28 8 2023
entrez: 28 8 2023
Statut: aheadofprint

Résumé

The European Union Medical Device Regulation 2017/745 challenges key stakeholders to follow transparent and rigorous approaches to the clinical evaluation of medical devices. The purpose of this study is a systematic evaluation of published clinical evidence underlying selected high-risk cardiovascular medical devices before and after market access in the European Union (CE marking) between 2000 and 2021. Prespecified strategies were applied to identify published studies of prospective design evaluating 71 high-risk cardiovascular devices in 7 different classes (bioresorbable coronary scaffolds, left atrial appendage occlusion devices, transcatheter aortic valve implantation systems, transcatheter mitral valve repair/replacement systems, surgical aortic and mitral heart valves, leadless pacemakers, subcutaneous implantable cardioverter-defibrillator). The search time-span covered 20 years (2000-2021). Details of study design, patient population, intervention(s) and primary outcome(s) were summarized, and assessed with respect to timing of the corresponding CE-mark approval. At least one prospective clinical trial was identified for 70% (50/71) of the prespecifed devices. Overall, 473 reports of 308 prospectively designed studies (enrolling 97,886 individuals) were deemed eligible, including 81% (251/308) prospective non-randomized clinical trials (66,186 individuals) and 19% (57/308) randomized clinical trials (31,700 individuals). Preregistration of the study protocol was available in 49% (150/308) studies, and 16% (48/308) had a peer-reviewed publicly available protocol. Device-related adverse events were evaluated in 82% (253/308) of studies. An outcome adjudication process was reported in 39% (120/308) of the studies. Sample size was larger for randomized in comparison to non-randomized trials (median of 304 versus 100 individuals, p<0.001). No randomized clinical trial published before CE-mark approval for any of the devices was identified. Non-randomized clinical trials were predominantly published after the corresponding CE-mark approval of the device under evaluation (89%, 224/251). Sample sizes were smaller for studies published before (median of 34 individuals) than after (median of 135 individuals) CE-mark approval (p<0.001). Clinical trials with larger sample sizes (>50 individuals) and those with longer recruitment periods were more likely to be published after CE-mark approval, and were more frequent during the period 2016-2021. The quantity and quality of publicly available data from prospective clinical investigations across selected categories of cardiovascular devices, before and after CE approval during the period 2000-2021, was deemed insufficient. The majority of studies were non-randomized, with increased risk of bias, and performed in small populations without provision of power calculations, and none of the reviewed devices had randomized trial results published prior to CE mark certification.

Sections du résumé

BACKGROUND AND AIMS OBJECTIVE
The European Union Medical Device Regulation 2017/745 challenges key stakeholders to follow transparent and rigorous approaches to the clinical evaluation of medical devices. The purpose of this study is a systematic evaluation of published clinical evidence underlying selected high-risk cardiovascular medical devices before and after market access in the European Union (CE marking) between 2000 and 2021.
METHODS METHODS
Prespecified strategies were applied to identify published studies of prospective design evaluating 71 high-risk cardiovascular devices in 7 different classes (bioresorbable coronary scaffolds, left atrial appendage occlusion devices, transcatheter aortic valve implantation systems, transcatheter mitral valve repair/replacement systems, surgical aortic and mitral heart valves, leadless pacemakers, subcutaneous implantable cardioverter-defibrillator). The search time-span covered 20 years (2000-2021). Details of study design, patient population, intervention(s) and primary outcome(s) were summarized, and assessed with respect to timing of the corresponding CE-mark approval.
RESULTS RESULTS
At least one prospective clinical trial was identified for 70% (50/71) of the prespecifed devices. Overall, 473 reports of 308 prospectively designed studies (enrolling 97,886 individuals) were deemed eligible, including 81% (251/308) prospective non-randomized clinical trials (66,186 individuals) and 19% (57/308) randomized clinical trials (31,700 individuals). Preregistration of the study protocol was available in 49% (150/308) studies, and 16% (48/308) had a peer-reviewed publicly available protocol. Device-related adverse events were evaluated in 82% (253/308) of studies. An outcome adjudication process was reported in 39% (120/308) of the studies. Sample size was larger for randomized in comparison to non-randomized trials (median of 304 versus 100 individuals, p<0.001). No randomized clinical trial published before CE-mark approval for any of the devices was identified. Non-randomized clinical trials were predominantly published after the corresponding CE-mark approval of the device under evaluation (89%, 224/251). Sample sizes were smaller for studies published before (median of 34 individuals) than after (median of 135 individuals) CE-mark approval (p<0.001). Clinical trials with larger sample sizes (>50 individuals) and those with longer recruitment periods were more likely to be published after CE-mark approval, and were more frequent during the period 2016-2021.
CONCLUSIONS CONCLUSIONS
The quantity and quality of publicly available data from prospective clinical investigations across selected categories of cardiovascular devices, before and after CE approval during the period 2000-2021, was deemed insufficient. The majority of studies were non-randomized, with increased risk of bias, and performed in small populations without provision of power calculations, and none of the reviewed devices had randomized trial results published prior to CE mark certification.

Identifiants

pubmed: 37638967
pii: 7249156
doi: 10.1093/eurheartj/ehad567
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Informations de copyright

© The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

Auteurs

George Cm Siontis (GC)

Department of Cardiology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland.

Bernadette Coles (B)

Velindre University NHS Trust Library and Knowledge Service, CardiffUK.

Jonas D Häner (JD)

Department of Cardiology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland.

Laurna McGovern (L)

Department of Cardiology and Cardiovascular Research Institute (CVRI) Dublin, Mater Private Network, Dublin, Ireland; School of Pharmacy and Biomolecular Sciences, RCSI University of Medicine and Health Sciences, Dublin, Ireland.

Joanna Bartkowiak (J)

Department of Cardiology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland.

J J Coughlan (JJ)

Department of Cardiology and Cardiovascular Research Institute (CVRI) Dublin, Mater Private Network, Dublin, Ireland; School of Pharmacy and Biomolecular Sciences, RCSI University of Medicine and Health Sciences, Dublin, Ireland.

Alessandro Spirito (A)

Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.

Roberto Galea (R)

Department of Cardiology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland.

Andreas Haeberlin (A)

Department of Cardiology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland.

Fabien Praz (F)

Department of Cardiology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland.

Daijiro Tomii (D)

Department of Cardiology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland.

Tom Melvin (T)

School of Medicine, Trinity College, Dublin, Ireland.

André Frenk (A)

Department of Cardiology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland.

Robert A Byrne (RA)

Department of Cardiology and Cardiovascular Research Institute (CVRI) Dublin, Mater Private Network, Dublin, Ireland; School of Pharmacy and Biomolecular Sciences, RCSI University of Medicine and Health Sciences, Dublin, Ireland.

Alan G Fraser (AG)

Department of Cardiology, University Hospital of Wales, Cardiff, UK.

Stephan Windecker (S)

Department of Cardiology, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland.

Classifications MeSH