Effect of Metrics-Based Simulation Training to Proficiency on Procedure Quality and Errors Among Novice Cardiac Device Implanters: The IMPROF Randomized Trial.
Journal
JAMA network open
ISSN: 2574-3805
Titre abrégé: JAMA Netw Open
Pays: United States
ID NLM: 101729235
Informations de publication
Date de publication:
01 08 2023
01 08 2023
Historique:
medline:
1
9
2023
pubmed:
31
8
2023
entrez:
31
8
2023
Statut:
epublish
Résumé
In cardiac device implant training, there is no common system to objectively assess trainees' ability to perform tasks at predetermined performance levels before in vivo practice; therefore, patients are potentially exposed to risks related to operators' early learning curve. To assess the effect on implant performance quality of novel metrics-based simulation training to proficiency (proficiency-based progression [PBP]) vs traditional simulation-based training (SBT). In this prospective randomized trial, conducted between March 8, 2022 and November 24, 2022, novice implanters were randomized (blinded) 1:1 to participate in an SBT curriculum (procedural knowledge e-learning and in-person simulation training) at an international skills training center, with proficiency demonstration requirements at each training stage for advancing (PBP approach) or without the requirements. Ultimately, trainees performed a cardiac resynchronization therapy (CRT) implant using virtual reality simulation. The procedure was video-recorded and subsequently scored using previously validated metrics by 2 independent assessors blinded to group. Physicians who had already implanted more than 20 pacemakers or defibrillators and fewer than 200 CRT systems as the first operator were eligible. Thirty-two implanters from 10 countries voluntarily enrolled in the training program and were randomized; 30 (15 per group) started and completed training. Data analysis was performed from November 27 to December 22, 2022. Training with PBP vs SBT. The primary outcome comprised 4 objectively assessed performance metrics derived from the video-recordings: number of procedural steps completed, errors, critical errors, and all errors combined. Baseline experience of the 30 participants (19 [63%] male; mean [SD] number of years in implant practice, 2.0 [1.8]; median [IQR] number of implanted pacemakers or defibrillators, 47.5 [30.0-115.0]; median [IQR] number of implanted CRT systems, 3.0 [1.25-10.0]) was similar between study groups. Compared with the SBT group, the PBP group completed 27% more procedural steps (median [IQR], 31 [30-32] vs 24 [22-27]; P < .001) and made 73% fewer errors (median [IQR], 2 [1-3] vs 7 [5-8]; P < .001), 84% fewer critical errors (median [IQR], 1 [0-1] vs 3 [3-5]; P < .001), and 77% fewer all errors combined (errors plus critical errors) (median [IQR], 3 [1-3] vs 11 [8-12]; P < .001); 14 of the 15 PBP trainees (93%) demonstrated the predefined target performance level vs 0 of the 15 SBT trainees. In this randomized trial, the PBP approach to novice implanter training generated superior objectively assessed performance vs SBT. If implemented broadly and systematically, PBP training may ensure safe and effective performance standards before trainees proceed to (supervised) in vivo practice. Future studies are needed to verify implications on procedure-related patient complications. ClinicalTrials.gov Identifier: NCT05952908.
Identifiants
pubmed: 37651144
pii: 2808943
doi: 10.1001/jamanetworkopen.2023.22750
pmc: PMC10472192
doi:
Banques de données
ClinicalTrials.gov
['NCT05952908']
Types de publication
Randomized Controlled Trial
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Pagination
e2322750Références
Arthroscopy. 2015 Oct;31(10):1854-71
pubmed: 26341047
Circ Arrhythm Electrophysiol. 2020 May;13(5):e008280
pubmed: 32281393
Int J Cardiol. 2019 Aug 15;289:63-69
pubmed: 31088758
Eur Heart J. 2019 Jun 1;40(21):1728-1738
pubmed: 30226525
JACC Clin Electrophysiol. 2017 Nov;3(11):1296-1305
pubmed: 29759627
Europace. 2016 Jul;18(7):1010-5
pubmed: 26324840
JACC Clin Electrophysiol. 2020 Apr;6(4):382-392
pubmed: 32327071
J Am Coll Cardiol. 2011 Aug 30;58(10):1001-6
pubmed: 21867833
Europace. 2017 Aug 01;19(suppl_2):ii1-ii90
pubmed: 28903470
Ann Surg. 2005 Feb;241(2):364-72
pubmed: 15650649
Ann Surg. 2021 Aug 1;274(2):281-289
pubmed: 33630473
Int J Cardiol. 2020 May 15;307:48-54
pubmed: 32081470
Acad Med. 2004 Oct;79(10 Suppl):S70-81
pubmed: 15383395
Europace. 2018 Feb 1;20(2):386-391
pubmed: 29300970
Acad Med. 2015 Nov;90(11):1471-86
pubmed: 26375267
Ann Surg. 1997 May;225(5):445-58
pubmed: 9193173
Clin Cardiol. 2021 Jun;44(6):739-747
pubmed: 34032293
Can J Cardiol. 2021 Nov;37(11):1857-1860
pubmed: 34571165
Pacing Clin Electrophysiol. 2017 Jul;40(7):834-842
pubmed: 28439940
Eur Heart J. 2014 May;35(18):1186-94
pubmed: 24347317
Europace. 2009 Aug;11 Suppl 3:iii1-26
pubmed: 19710176
N Engl J Med. 2013 Oct 10;369(15):1434-42
pubmed: 24106936
J Med Econ. 2019 Nov;22(11):1171-1178
pubmed: 31373521
N Engl J Med. 2014 Aug 28;371(9):794-5
pubmed: 25075620
Ann Surg. 2021 May 1;273(5):e173-e175
pubmed: 33065648
JAMA Surg. 2020 Jul 1;155(7):590-598
pubmed: 32374371
Heart Rhythm. 2012 May;9(5):728-35
pubmed: 22182495
Acad Med. 2011 Nov;86(11):e8-9
pubmed: 22030671
Heart. 2005 Apr;91(4):500-6
pubmed: 15772212
Ulster Med J. 2012 Sep;81(3):107-13
pubmed: 23620606
Open Heart. 2021 May;8(1):
pubmed: 33972405
Acad Med. 2013 Aug;88(8):1178-86
pubmed: 23807104
Ann Surg. 2013 Jun;257(6):1025-31
pubmed: 23426342
Acad Med. 2015 Nov;90(11):1438-41
pubmed: 26375269
CJC Open. 2022 Aug 10;4(11):946-958
pubmed: 36444361
Heart Rhythm. 2016 Jan;13(1):e3-e37
pubmed: 26392325
Open Heart. 2015 Feb 17;2(1):e000198
pubmed: 25745566