Development of a urinometer for automatic measurement of urine flow in catheterized patients.
Journal
PloS one
ISSN: 1932-6203
Titre abrégé: PLoS One
Pays: United States
ID NLM: 101285081
Informations de publication
Date de publication:
2023
2023
Historique:
received:
19
04
2023
accepted:
07
08
2023
medline:
4
9
2023
pubmed:
31
8
2023
entrez:
31
8
2023
Statut:
epublish
Résumé
Urinary flow measurement and colorimetry are vital medical indicators for critically ill patients in intensive care units. However, there is a clinical need for low-cost, continuous urinary flow monitoring devices that can automatically and in real-time measure urine flow. This need led to the development of a non-invasive device that is easy to use and does not require proprietary disposables. The device operates by detecting urine flow using an infrared barrier that returns an unequivocal pattern, and it is capable of measuring the volume of liquid in real-time, storing the history with a precise date, and returning alarms to detect critical trends. The device also has the ability to detect the color of urine, allowing for extended data and detecting problems in catheterized patients such as hematuria. The device is proposed as an automated clinical decision support system that utilizes the concept of the Internet of Medical Things. It works by using a LoRa communication method with the LoRaWAN protocol to maximize the distance to access points, reducing infrastructure costs in massive deployments. The device can send data wirelessly for remote monitoring and allows for the collection of data on a dashboard in a pseudonymous way. Tests conducted on the device using a gold standard medical grade infusion pump and fluid densities within the 1.005 g/ml to 1.030 g/ml urine density range showed that droplets were satisfactorily captured in the range of flows from less than 1 ml/h to 500 ml/h, which are acceptable ranges for urinary flow. Errors ranged below 15%, when compared to the values obtained by the hospital infusion pump used as gold standard. Such values are clinically adequate to detect changes in diuresis patterns, specially at low urine output ranges, related to renal disfunction. Additionally, tests carried out with different color patterns indicate that it detects different colors of urine with a precision in detecting RGB values <5%. In conclusion, the results suggest that the device can be useful in automatically monitoring diuresis and colorimetry in real-time, which can facilitate the work of nursing and provide automatic decision-making support to intensive care physicians.
Identifiants
pubmed: 37651353
doi: 10.1371/journal.pone.0290319
pii: PONE-D-23-11555
pmc: PMC10470914
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
e0290319Informations de copyright
Copyright: © 2023 Lafuente et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Déclaration de conflit d'intérêts
The authors have declared that no competing interests exist.
Références
Intensive Care Med. 2012 Oct;38(10):1647-53
pubmed: 22777516
Sci Rep. 2019 May 29;9(1):8020
pubmed: 31142754
Sci Rep. 2021 Aug 31;11(1):17429
pubmed: 34465821
Clin Infect Dis. 2017 May 15;64(suppl_2):S127-S130
pubmed: 28475778
Rev Med Interne. 2022 Jan;43(1):31-38
pubmed: 33736891
Nat Rev Nephrol. 2013 Oct;9(10):568-70
pubmed: 24018409
Sensors (Basel). 2010;10(1):934-51
pubmed: 22315578
Biomed Res Int. 2014;2014:587593
pubmed: 24605331
Ann Intensive Care. 2019 Mar 13;9(1):37
pubmed: 30868286
Sensors (Basel). 2021 Jan 10;21(2):
pubmed: 33435177
Sensors (Basel). 2018 Nov 16;18(11):
pubmed: 30453524
N Engl J Med. 1998 Mar 5;338(10):671-5
pubmed: 9486997
J Am Coll Nutr. 2021 Feb;40(2):172-179
pubmed: 32330109
Crit Care. 2020 Nov 25;24(1):661
pubmed: 33234161
Sensors (Basel). 2012 Sep 26;12(10):13109-25
pubmed: 23201988
South Med J. 2012 Jan;105(1):43-7
pubmed: 22189666
J Cardiothorac Vasc Anesth. 2021 Dec;35(12):3774-3788
pubmed: 33199113
Sensors (Basel). 2010;10(12):10714-32
pubmed: 22163495