Primary Stability and Bone Contact Loading Evaluation of Suture and Screw based Coracoid Graft Fixation for Anterior Glenoid Bone Loss.

biomechanics cerclage contact pressure coracoid fixation glenoid bone loss suture-based fixation

Journal

The American journal of sports medicine
ISSN: 1552-3365
Titre abrégé: Am J Sports Med
Pays: United States
ID NLM: 7609541

Informations de publication

Date de publication:
09 2023
Historique:
medline: 4 9 2023
pubmed: 1 9 2023
entrez: 1 9 2023
Statut: ppublish

Résumé

Reconstruction techniques for anterior glenoid bone loss have seen a trend from screws to suture-based fixations. However, comparative biomechanical data, including primary fixation and glenoid-graft contact pressure mapping, are limited. Suture-based bone block cerclage (BBC) and suspensory suture button (SB) techniques provide similar primary fixation and cyclic stability to double-screw fixation but with higher contact loading at the bony interface. Controlled laboratory study. In total, 60 cadaveric scapulae were prepared to simulate anterior glenoid bone loss with coracoid autograft reconstruction. Graft fixation was performed with 3 different techniques: (1) an interconnected all-suture BBC, (2) 2 SB suspensions, and (3) 2 screws. Initial compression was analyzed during primary fixation. Cyclic peak loading with 50 N and 100 N over 250 cycles at 1 Hz was performed with a constant valley load of 25 N. Optical recording and pressure foils allowed for spatial bone block tracking and contact pressure mapping at the glenoid-graft interface. Load-to-failure testing was performed at a rate of 1.5 mm/s with ultimate load and stiffness measured. Initial graft compression was higher with screw fixation (141 ± 5 N) compared with suture-based fixations ( Both SB and interconnected cerclage fixation improved dynamic contact loading compared with screw fixation in a biomechanical glenoid bone loss model. Cerclage fixation was biomechanically comparable with screw fixation but with a greater variability. SB fixation showed significantly lower primary fixation strength and greater bone block rotation and migration. Suture-based bone block fixations improved graft-glenoid contact loading, but the overall clinical consequence on healing remains unclear.

Sections du résumé

BACKGROUND
Reconstruction techniques for anterior glenoid bone loss have seen a trend from screws to suture-based fixations. However, comparative biomechanical data, including primary fixation and glenoid-graft contact pressure mapping, are limited.
HYPOTHESIS
Suture-based bone block cerclage (BBC) and suspensory suture button (SB) techniques provide similar primary fixation and cyclic stability to double-screw fixation but with higher contact loading at the bony interface.
STUDY DESIGN
Controlled laboratory study.
METHODS
In total, 60 cadaveric scapulae were prepared to simulate anterior glenoid bone loss with coracoid autograft reconstruction. Graft fixation was performed with 3 different techniques: (1) an interconnected all-suture BBC, (2) 2 SB suspensions, and (3) 2 screws. Initial compression was analyzed during primary fixation. Cyclic peak loading with 50 N and 100 N over 250 cycles at 1 Hz was performed with a constant valley load of 25 N. Optical recording and pressure foils allowed for spatial bone block tracking and contact pressure mapping at the glenoid-graft interface. Load-to-failure testing was performed at a rate of 1.5 mm/s with ultimate load and stiffness measured.
RESULTS
Initial graft compression was higher with screw fixation (141 ± 5 N) compared with suture-based fixations (
CONCLUSION
Both SB and interconnected cerclage fixation improved dynamic contact loading compared with screw fixation in a biomechanical glenoid bone loss model. Cerclage fixation was biomechanically comparable with screw fixation but with a greater variability. SB fixation showed significantly lower primary fixation strength and greater bone block rotation and migration.
CLINICAL RELEVANCE
Suture-based bone block fixations improved graft-glenoid contact loading, but the overall clinical consequence on healing remains unclear.

Identifiants

pubmed: 37656204
doi: 10.1177/03635465231188976
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

2858-2868

Auteurs

Daniel Ritter (D)

Arthrex Department of Orthopedic Research, Munich, Germany.

Abdul-Ilah Hachem (AI)

Department of Orthopedic and Traumatology Surgery, Hospital Universitari Bellvitge & Centro Médico Teknon, University of Barcelona, Barcelona, Spain.

Markus Scheibel (M)

Schulthess Clinic, Zurich, Switzerland.
Department of Shoulder and Elbow Surgery, Center for Musculoskeletal Surgery, Charité-Universitaetsmedizin Berlin, Berlin, Germany.

Patric Raiss (P)

OCM Clinic, Munich, Germany.

Patrick J Denard (PJ)

Southern Oregon Orthopedics, Medford, Oregon, USA.

Alexander Campagnoli (A)

Arthrex Department of Orthopedic Research, Munich, Germany.

Coen A Wijdicks (CA)

Arthrex Department of Orthopedic Research, Munich, Germany.

Samuel Bachmaier (S)

Arthrex Department of Orthopedic Research, Munich, Germany.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH