Discrepancies in clavicle-to-carotid bifurcation length measurements for transcarotid artery revascularization using different imaging modalities.

CTA Clavicle-to-carotid bifurcation length Duplex ultrasound Transcarotid artery revascularization

Journal

Journal of vascular surgery
ISSN: 1097-6809
Titre abrégé: J Vasc Surg
Pays: United States
ID NLM: 8407742

Informations de publication

Date de publication:
12 2023
Historique:
received: 26 06 2023
revised: 18 08 2023
accepted: 23 08 2023
medline: 21 11 2023
pubmed: 2 9 2023
entrez: 1 9 2023
Statut: ppublish

Résumé

Transcarotid artery revascularization (TCAR) has emerged as an effective method for carotid artery stenting. However, anatomic eligibility for TCAR is most often limited by an inadequate clavicle-to-carotid bifurcation length of <5 cm. Preoperative clavicle-to-carotid bifurcation distances may be underestimated when using conventional straight-line measurements on computed tomographic angiography (CTA) imaging. We therefore compared clavicle-to-carotid bifurcation lengths as measured by straight-line CTA, center-line CTA, and intraoperative duplex ultrasound (US), to assess potential differences. We conducted a single-center, retrospective review of consecutive TCAR procedures performed between 2016 and 2019 for atherosclerotic carotid disease. For each patient, we compared clavicle-to-carotid bifurcation lengths measured by straight-line CTA, center-line CTA using TeraRecon image reconstruction, and intraoperative duplex US with neck extension and rotation. We further assessed patient and imaging characteristics in individuals with a ≥0.5 cm difference among the measurement methods. In particular, common carotid artery (CCA) tortuosity, defined as the inability to visualize the entire CCA from clavicle to carotid bifurcation on both a single coronal and sagittal imaging cut, was examined as a contributing factor for these discrepancies. Of the 70 TCAR procedures identified, 46 had all three imaging modalities available for review. The median clavicle-to-carotid bifurcation length was found to be 6.4 cm (interquartile range [IQR], 5.4-6.7 cm) on straight-line CTA, 7.0 cm (IQR, 6.0-7.5 cm) on intraoperative duplex US, and 7.2 cm (IQR, 6.5-7.5 cm) on center-line CTA (P < .001). Patients with a ≥0.5 cm difference between their straight-line CTA and either their intraoperative duplex US or center-line CTA measurements were more likely to have tortuous CCAs (60.0% vs 19.1%; P = .01; 51.4% vs 0.0%; P = .01). There were no notable differences in age, gender, prior neck/cervical spine surgery, or neck immobility among these individuals. In patients with tortuous CCAs, duplex US and center-line CTA measurements added 1.0 cm (IQR, 0.6-1.5 cm) and 1.1 cm (IQR, 0.9-1.6 cm) more in length than straight-line CTA measurements, respectively. There was a strong linear correlation between the additional lengths provided by duplex US measurements and those provided by center-line CTA measurements for each individual within the tortuous CCA group (r = 0.83). The use of straight-line CTA during preoperative planning can underestimate the clavicle-to-carotid bifurcation lengths in patients undergoing carotid revascularization, particularly in those with tortuous CCAs. Both duplex US performed with extended-neck surgical positioning and center-line CTA provide similar and longer carotid length measurements, and should be utilized in patients with tortuous carotid vessels to better determine TCAR anatomic eligibility.

Identifiants

pubmed: 37657687
pii: S0741-5214(23)01938-9
doi: 10.1016/j.jvs.2023.08.124
pii:
doi:

Types de publication

Journal Article Research Support, N.I.H., Extramural

Langues

eng

Sous-ensembles de citation

IM

Pagination

1439-1448.e2

Subventions

Organisme : NHLBI NIH HHS
ID : T32 HL007734
Pays : United States

Informations de copyright

Copyright © 2023 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

Déclaration de conflit d'intérêts

Disclosures M.L.S. reports consulting fees from Cook Medical, Endologix Inc, Medtronic, Abbott Laboratories, and Silk Road Medical.

Auteurs

Winona W Wu (WW)

Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA.

Sai Divya Yadavalli (SD)

Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA.

Jinny J Lu (JJ)

Division of Vascular and Endovascular Surgery, Harbor-UCLA Medical Center, Los Angeles, CA.

Jane J Cheng (JJ)

Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA.

Patric Liang (P)

Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA.

Kirsten Dansey (K)

Division of Vascular and Endovascular Surgery, University of Washington, Seattle, WA.

Lars Stangenberg (L)

Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA.

Mark C Wyers (MC)

Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA.

Allen D Hamdan (AD)

Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA.

Marc L Schermerhorn (ML)

Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA. Electronic address: mscherm@bidmc.harvard.edu.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH