Static stability of novel uncemented elbow hemiarthroplasty stabilized with ligament reconstruction.

Elbow hemiarthroplasty distal humerus trauma elbow arthritis elbow instability ligament reconstruction uncemented hemiarthroplasty

Journal

Journal of shoulder and elbow surgery
ISSN: 1532-6500
Titre abrégé: J Shoulder Elbow Surg
Pays: United States
ID NLM: 9206499

Informations de publication

Date de publication:
Jan 2024
Historique:
received: 18 05 2023
revised: 20 07 2023
accepted: 29 07 2023
pubmed: 3 9 2023
medline: 3 9 2023
entrez: 2 9 2023
Statut: ppublish

Résumé

The purpose of this study was to create a model to simulate treatment of unreconstructable distal humerus fractures with hemiarthroplasty. Stability was restored with a latest plate-system that simultaneously tensions medial and lateral collateral ligament grafts. Static varus and valgus elbow stability was tested in 11 cadaver elbows with intact ligaments and capsule at 5 flexion angles (0°, 30°, 60°, 90°, 120°). The elbows were then destabilized via release of all ligaments and capsular attachments. The distal humerus articular cartilage was excised and replaced with an uncemented hemiarthroplasty. Ligament reconstruction was subsequently performed, and elbow stability was measured and compared to the native state. Dimensions of the hemiarthroplasty component were compared to native elbow dimensions to assess and quantify any existing relationship to elbow stability. A hemiarthroplasty was implanted in all specimens. A size mismatch occurred between the distal humerus trochlea and the olecranon fossa in all specimens and averaged 6.3 mm. Following ligament reconstruction, specimens reproduced the flexion angle-dependent stability of native elbows to both varus and valgus stress. On the medial side, elbow joint stability in mid-flexion was approximately 7% tighter after hemiarthroplasty. Laterally, the elbow was approximately 15% tighter after hemiarthroplasty and demonstrated peak stability in full flexion. The 3 assessed hemiarthroplasty components and bony dimensions did not exhibit any relationship between implant-bone mismatch and elbow stability after ligamentous reconstruction. Cadaveric elbow specimens underwent uncemented hemiarthroplasty with soft tissue stabilization with a novel technique for ligament reconstruction. Following hemiarthroplasty and ligament reconstruction, these specimens maintained secure fixation between ligament and bone. Static stability was maintained at varying degrees of elbow flexion regardless of variable mismatch between the hemiarthroplasty component and the native olecranon fossa.

Sections du résumé

BACKGROUND BACKGROUND
The purpose of this study was to create a model to simulate treatment of unreconstructable distal humerus fractures with hemiarthroplasty. Stability was restored with a latest plate-system that simultaneously tensions medial and lateral collateral ligament grafts.
MATERIALS AND METHODS METHODS
Static varus and valgus elbow stability was tested in 11 cadaver elbows with intact ligaments and capsule at 5 flexion angles (0°, 30°, 60°, 90°, 120°). The elbows were then destabilized via release of all ligaments and capsular attachments. The distal humerus articular cartilage was excised and replaced with an uncemented hemiarthroplasty. Ligament reconstruction was subsequently performed, and elbow stability was measured and compared to the native state. Dimensions of the hemiarthroplasty component were compared to native elbow dimensions to assess and quantify any existing relationship to elbow stability.
RESULTS RESULTS
A hemiarthroplasty was implanted in all specimens. A size mismatch occurred between the distal humerus trochlea and the olecranon fossa in all specimens and averaged 6.3 mm. Following ligament reconstruction, specimens reproduced the flexion angle-dependent stability of native elbows to both varus and valgus stress. On the medial side, elbow joint stability in mid-flexion was approximately 7% tighter after hemiarthroplasty. Laterally, the elbow was approximately 15% tighter after hemiarthroplasty and demonstrated peak stability in full flexion. The 3 assessed hemiarthroplasty components and bony dimensions did not exhibit any relationship between implant-bone mismatch and elbow stability after ligamentous reconstruction.
CONCLUSION CONCLUSIONS
Cadaveric elbow specimens underwent uncemented hemiarthroplasty with soft tissue stabilization with a novel technique for ligament reconstruction. Following hemiarthroplasty and ligament reconstruction, these specimens maintained secure fixation between ligament and bone. Static stability was maintained at varying degrees of elbow flexion regardless of variable mismatch between the hemiarthroplasty component and the native olecranon fossa.

Identifiants

pubmed: 37659704
pii: S1058-2746(23)00638-9
doi: 10.1016/j.jse.2023.07.037
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

156-163

Informations de copyright

Copyright © 2023 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

Auteurs

Emerald D Robertson (ED)

University of Pittsburgh Medical Center, Pittsburgh, PA, USA.

JaHea Gu (J)

University of Pittsburgh Medical Center, Pittsburgh, PA, USA.

Colin H Beckwitt (CH)

Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA, USA.

Maria A Munsch (MA)

Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA, USA.

Mark E Baratz (ME)

University of Pittsburgh Medical Center, Pittsburgh, PA, USA.

Robert A Kaufmann (RA)

Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA, USA. Electronic address: kaufra@upmc.edu.

Classifications MeSH