Résumé
This study investigated the accuracy in achieving proper lower limb alignment and component positions after total knee replacement (TKR) with image-free and image-based robotic-assisted TKR. A total of 129 patients (166 knees) suffering from end-stage knee arthritis who underwent TKA operated by robotic-assisted surgery between the years 2018 and mid-2021 were recruited. Radiological outcomes were compared between image-free and image-based robotic-assisted surgical systems. There were significant differences between the two robotic systems when comparing the mean planned component alignment and the mean measured alignment on radiographs, in which the image-free robotic-assisted system was more varus, whereas the image-based robotic-assisted system was more valgus for both the mean femoral and tibial component coronal alignment (p < 0.001). For tibial component sagittal alignment, the image-based group had a larger deviation from the planned posterior slope (p < 0.001). Image-free and image-based robotic assisted TKR had differing accuracy in femoral and tibial alignment.
Sections du résumé
BACKGROUND
BACKGROUND
This study investigated the accuracy in achieving proper lower limb alignment and component positions after total knee replacement (TKR) with image-free and image-based robotic-assisted TKR.
METHODS
METHODS
A total of 129 patients (166 knees) suffering from end-stage knee arthritis who underwent TKA operated by robotic-assisted surgery between the years 2018 and mid-2021 were recruited. Radiological outcomes were compared between image-free and image-based robotic-assisted surgical systems.
RESULTS
RESULTS
There were significant differences between the two robotic systems when comparing the mean planned component alignment and the mean measured alignment on radiographs, in which the image-free robotic-assisted system was more varus, whereas the image-based robotic-assisted system was more valgus for both the mean femoral and tibial component coronal alignment (p < 0.001). For tibial component sagittal alignment, the image-based group had a larger deviation from the planned posterior slope (p < 0.001).
CONCLUSION
CONCLUSIONS
Image-free and image-based robotic assisted TKR had differing accuracy in femoral and tibial alignment.
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
e2574Informations de copyright
© 2023 The Authors. The International Journal of Medical Robotics and Computer Assisted Surgery published by John Wiley & Sons Ltd.
Références
Skou ST, Roos EM, Laursen MB, et al. A randomized, controlled trial of total knee replacement. N Engl J Med. 2015;373(17):1597-1606. https://doi.org/10.1056/nejmoa1505467
Ritter MA, Faris PM, Keating EM, Meding JB. Postoperative alignment of total knee replacement its effect on survival. Clinical orthopaedics and related research (1976-2007). Clin Orthop Relat Res. 1994;299:153-156. https://doi.org/10.1097/00003086-199402000-00021
Hadi M, Barlow T, Ahmed I, Dunbar M, McCulloch P, Griffin D. Does malalignment affect revision rate in total knee replacements: a systematic review of the literature. SpringerPlus. 2015;4(1):835. https://doi.org/10.1186/s40064-015-1604-4
Jeffery RS, Morris RW, Denham RA. Coronal alignment after total knee replacement. J Bone Joint Surg Br. 1991;73(5):709-714. https://doi.org/10.1302/0301-620x.73b5.1894655
Saragaglia D, Rubens-Duval B, Gaillot J, Lateur G, Pailhé R. Total knee arthroplasties from the origin to navigation: history, rationale, indications. Int Orthop. 2019;43(3):597-604. https://doi.org/10.1007/s00264-018-3913-z
Cheng T, Zhao S, Peng X, Zhang X. Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? Knee Surg Sports Traumatol Arthrosc. 2012;20(7):1307-1322. https://doi.org/10.1007/s00167-011-1588-8
Fu Y, Wang M, Liu Y, Fu Q. Alignment outcomes in navigated total knee arthroplasty: a meta-analysis. Knee Surg Sports Traumatol Arthrosc. 2012;20(6):1075-1082. https://doi.org/10.1007/s00167-011-1695-6
Han HS, Chang CB, Seong SC, Lee S, Lee MC. Evaluation of anatomic references for tibial sagittal alignment in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2008;16(4):373-377. https://doi.org/10.1007/s00167-008-0486-1
Fujimoto E, Sasashige Y, Masuda Y, et al. Significant effect of the posterior tibial slope and medial/lateral ligament balance on knee flexion in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2013;21(12):2704-2712. https://doi.org/10.1007/s00167-012-2059-6
Yoo JH, Chang CB, Shin KS, Seong SC, Kim TK. Anatomical references to assess the posterior tibial slope in total knee arthroplasty: a comparison of 5 anatomical axes. J Arthroplasty. 2008;23(4):586-592. https://doi.org/10.1016/j.arth.2007.05.006
Kayani B, Konan S, Ayuob A, Onochie E, Al-Jabri T, Haddad FS. Robotic technology in total knee arthroplasty: a systematic review. EFORT Open Rev. 2019;4(10):611-617. https://doi.org/10.1302/2058-5241.4.190022
Mahoney O, Kinsey T, Sodhi N, et al. Improved component placement accuracy with robotic-arm assisted total knee arthroplasty. J Knee Surg. 2022;35(3):337-344. https://doi.org/10.1055/s-0040-1715571
Li C, Zhang Z, Wang G, et al. Accuracies of bone resection, implant position, and limb alignment in robotic-arm-assisted total knee arthroplasty: a prospective single-centre study. J Orthop Surg Res. 2022;17(1):61. https://doi.org/10.1186/s13018-022-02957-1
Deckey DG, Rosenow CS, Verhey JT, et al. Robotic-assisted total knee arthroplasty improves accuracy and precision compared to conventional techniques. Bone & Jt J. 2021;103-B(6 Suppl A):74-80. https://doi.org/10.1302/0301-620x.103b6.bjj-2020-2003.r1
Sicat CS, Chow JC, Kaper B, Mitra R, Xie J, Schwarzkopf R. Component placement accuracy in two generations of handheld robotics-assisted knee arthroplasty. Archives Orthop Trauma Surg. 2021;141(12):2059-2067. https://doi.org/10.1007/s00402-021-04040-6
Bollars P, Meshram P, Al Thani S, Schotanus MGM, Albelooshi A. Achieving functional alignment in total knee arthroplasty: early experience using a second-generation imageless semi-autonomous handheld robotic sculpting system. Int Orthop. 2023;47(2):585-593. https://doi.org/10.1007/s00264-022-05649-x
Seidenstein A, Birmingham M, Foran J, Ogden S. Better accuracy and reproducibility of a new robotically-assisted system for total knee arthroplasty compared to conventional instrumentation: a cadaveric study. Knee Surg Sports Traumatol Arthrosc. 2021;29(3):859-866. https://doi.org/10.1007/s00167-020-06038-w
Sires JD, Wilson CJ. CT validation of intraoperative implant position and knee alignment as determined by the MAKO total knee arthroplasty system. J Knee Surg. 2021;34(10):1133-1137. https://doi.org/10.1055/s-0040-1701447
Vermue H, Batailler C, Monk P, Haddad F, Luyckx T, Lustig S. The Evolution of Robotic Systems for Total Knee Arthroplasty, Each System Must Be Assessed for its Own Value: A Systematic Review of Clinical Evidence and Meta-Analysis. Archives of Orthopaedic and Trauma Surgery; 2022.
Beverland DE, Nunley RM, Heldreth M. Guidance for cementless best practice in total knee replacement 2019.