Percutaneous Treatment of Locked Pubic Symphysis with the Anterior Subcutaneous Pelvic Fixator (INFIX): A Case Report.
Journal
JBJS case connector
ISSN: 2160-3251
Titre abrégé: JBJS Case Connect
Pays: United States
ID NLM: 101596828
Informations de publication
Date de publication:
01 07 2023
01 07 2023
Historique:
medline:
25
9
2023
pubmed:
21
9
2023
entrez:
21
9
2023
Statut:
epublish
Résumé
A 54-year-old woman was involved in a motor vehicle collision and sustained a lateral compression type 1 pelvic ring fracture with pubic symphyseal dislocation or a "locked pubic symphysis." Her injury failed to reduce with closed reduction maneuvers under anesthesia and necessitated a percutaneous reduction using a distraction force applied through supra-acetabular placed pedicle screws. This anterior subcutaneous internal pelvic fixator (INFIX) was also used to stabilize the injury. This is the first reported case where a locked pubic symphysis, which failed standard closed reduction measures, was reduced and stabilized through a percutaneous technique, using the INFIX.
Identifiants
pubmed: 37733912
doi: 10.2106/JBJS.CC.23.00322
pii: 01709767-202309000-00088
doi:
Types de publication
Case Reports
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
Copyright © 2023 by The Journal of Bone and Joint Surgery, Incorporated.
Déclaration de conflit d'intérêts
Disclosure: The Disclosure of Potential Conflicts of Interest forms are provided with the online version of the article (http://links.lww.com/JBJSCC/C207).
Références
O'Toole RV, Sagebien C, Andersen RC, Nascone JW. Superior pubic ramus osteotomy to treat locked pubic symphysis: a case report. J Bone Joint Surg Am. 2006;88(7):1609-14.
Pushpasekaran N, Thampy S, Khaleel VM, Joseph S. Treatment of locked pubic symphysis by distraction osteotomy of the superior pubic ramus. JBJS Case Connect. 2020;10(2):E0196.
Eggers GW. Dislocations of the os coxae. Am J Surg. 1952;83(3):300-7.
Afshar A, Koushkzari M. Overlapped pubic symphysis; a case report and review of the literature. Arch Bone Jt Surg. 2015;3(3):212-6.
Avilucea FR, Whiting PS, Mir H. Posterior fixation of APC-2 pelvic ring injuries decreases rates of anterior plate failure and malunion. J Bone Joint Surg Am. 2016;98(11):944-51.
Sagi HC, Papp S. Comparative radiographic and clinical outcome of two-hole and multi-hole symphyseal plating. J Orthop Trauma. 2008;22(6):373-8.
Tornetta P III, Dickson K, Matta JM. Outcome of rotationally unstable pelvic ring injuries treated operatively. Clin Orthop Relat Res. 1996;329:147-51.
Van Loon P, Kuhn S, Hofmann A, Hessmann MH, Rommens PM. Radiological analysis, operative management and functional outcome of open book pelvic lesions: a 13-year cohort study. Injury. 2011;42(10):1012-9.
Collinge CA, Archdeacon MT, LeBus G. Saddle-horn injury of the pelvis. The injury, its outcomes, and associated male sexual dysfunction. J Bone Joint Surg Am. 2009;91(7):1630-6.
Collinge C, Archdeacon MT, Dulaney-Cripe E, Moed BR. Radiographic changes of implant failure after plating for pubic symphysis diastasis: an underappreciated reality? Clin Orthop Relat Res. 2012;470(8):2148-53.
Vaidya R, Colen R, Vigdorchik J, Tonnos F, Sethi A. Treatment of unstable pelvic ring injuries with an internal anterior fixator and posterior fixation: initial clinical series. J Orthop Trauma. 2012;26(1):1-8.
Vaidya R, Onwudiwe N, Roth M, Sethi A. Monoaxial pedicle screws are superior to polyaxial pedicle screws and the two pin external fixator for subcutaneous anterior pelvic fixation in a biomechanical analysis. Adv Orthop. 2013;2023:683120.
Eagan M, Kim H, Manson TT, Gary JL, Russell JP, Hsieh AH, O'Toole RV, Boulton CL. Internal anterior fixators for pelvic ring injuries: do monaxial pedicle screws provide more stiffness than polyaxial pedicle screws? Injury. 2015;46(6):996-1000.
Vigdorchik JM, Esquivel AO, Jin X, Yang KH, Vaidya R. Anterior internal fixator verses a femoral distractor and external fixation for sacroiliac joint compression and single stance gait testing: a mechanical study in synthetic bone. Int Orthop. 2013;37(7):1341-6.
Vaidya R, Martin AJ, Roth M, Nasr K, Gheraibeh P, Tonnos F. INFIX versus plating for pelvic fractures with disruption of the symphysis pubis. Int Orthop. 2017;41(8):1671-8.
Li KH, Sun BH, Zhu Y, Long HT. Locked pubic symphysis into the obturator foramen: a rare case presentation and literature review. Orthop Traumatol Surg Res. 2013;99(1):106-10.
Ansari S, Rollins J, Ebraheim NA. Locked pubic symphysis with ipsilateral fracture neck of a femur. J Trauma Acute Care Surg. 2003;54(2):376-8.
Blank AT, Gage M, Tejwani N, McLaurin T. Overlapping dislocation of the pubic symphysis with an open reduction and anterior and posterior pelvic ring fixation: a case report. JBJS Case Connect. 2015;5(1);e6.
Botanlioglu H, Bilsel N, Kaynak G, Unlu M. Open reduction technique for overlapping and locked pubic symphysis. Acta Orthop Traumatol Turc. 2012;46(1):77-81.
Catonné Y, Delattre O, Rouvillain JL, Richard F, Bahuet F. Disruption of the pubic symphysis with overriding impacted symphysis. Apropos of a case [in French]. Rev Chir Orthop Reparatrice Appar Mot. 1996;82(5):458-61.
Gordon RO, Mears DC. Lateral compression injury of the pelvis. A case report. JBJS. 1991;73(9):1399-401.
Maqungo S, Koller I, Roche S. Overlapping pubic symphysis dislocation: a case report and proposal of a classification system. SA Orthop J. 2010;9(4):74-7.
Sreesobh KV, Sageer AM, Raffic M. Locked overlapping dislocation of the pubic symphysis into the obturator foramen: a case report. J Orthop Surg. 2006;14(2):200-3.
Tadros AM, Lunsjo K, O'Brien P. Overlapping dislocation of the pubic symphysis: report of three cases and review of the literature. Arch Orthop Trauma Surg. 2009;129:679-83.
Thulasiraman V, Ramesh Pandian TR, Ashok S. Locked pubic symphysis—a case series. Injury Extra. 2010;41(2):20-4.
Cannada LK, Reinert CM. Case report: locked pubic symphysis: an open reduction technique. Clin Orthop Relat Res. 2009;467:2192-5.
Lee SR, Lee BJ. Unusual dislocation of the symphysis pubis: a case report. J Korean Orthop Assoc. 2002;37(3):450-2.
Robinson D, Hendel D, Halperin N. An overlapping pubic dislocation treated by closed reduction: case report and review of the literature. J Trauma Acute Care Surg. 1989;29(6):883-5.
Dorai CR, Kareem BA. Overlapping dislocation of pubic symphysis. Injury. 1991;22(4):329-30.
Webb P. Overlapping dislocation of the symphysis pubis: a case report. J Bone Joint Surg Am. 1977;59(6):839.
Tile M. Classification. Fractures of the Pelvis and Acetabulum. 2nd ed. London, UK: Lippincott, Williams & Wilkins; 1995:66-101.
Halici M, Karaman İ, Kafadar İ, Argun ALİ. Closed reduction and fixation of locked symphysis pubis using tubular external fixator: a case report. Eklem Hastalik Cerrahisi. 2013;24(2):121-3.
Küper MA, Trulson A, Stuby FM, Stöckle U, Konrads C. Complications of surgical approaches for stabilization of pelvic ring injuries: analysis of pitfalls and how to avoid them. J Orthop. 2020;20:261-7.
Kumbhare C, Meena S, Kamboj K, Trikha V. Use of INFIX for managing unstable anterior pelvic ring injuries: a systematic review. J Clin Orthop Trauma. 2020;11(6):970-5.
Bianco RJ, Aubin CE, Mac-Thiong JM, Wagnac E, Arnoux PJ. Pedicle screw fixation under nonaxial loads: a cadaveric study. Spine (Phila Pa 1976). 2016;41(3):E124-30.