Résumé
We investigated the effectiveness of cap-assisted colonoscopy conducted with the patient in the left lateral decubitus position at both the colonoscope's insertion and withdrawal timepoints compared to the effectiveness of colonoscopy without a cap conducted in the supine position at withdrawal. This was a case-control study, based on historical comparisons of patients over 2 time periods. The first group of patients underwent colonoscopies with a transparent cap and the patient was in the left lateral decubitus position at both the insertion and withdrawal timepoints from April to June 2019. The subsequent group underwent colonoscopies without a cap and with the patient in the supine position at withdrawal from July to September 2019. The rates of successful intubation, cecal intubation time, and number, size, shape, and location of the detected adenomas and sessile serrated lesions were compared between the 2 groups. Data from 644 colonoscopies (cap-assisted colonoscopy + left lateral decubitus position, n=320; other colonoscopies, n=324) were analyzed. The demographic characteristics and technical performances were similar. The SSL detection rate was significantly higher with cap-assisted colonoscopy and the left lateral decubitus position than with other colonoscopies (3.4% vs 0.93%, P=.029). The adenoma detection rates in the 2 groups were similar (31% and 28%, respectively, P=.43).Cap-assisted colonoscopy in the left lateral decubitus position may increase the detection rate of sessile serrated lesions compared to colonoscopy without a cap and supine position at withdrawal.
Identifiants
pubmed: 37746993
doi: 10.1097/MD.0000000000035264
pii: 00005792-202309220-00054
pmc: PMC10519449
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
e35264Informations de copyright
Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc.
Déclaration de conflit d'intérêts
The authors have no funding and conflicts of interest to disclose.
Références
Rex D, Rahmani EY, Haseman JH, et al. Relative sensitivity of colonoscopy and barium enema for detection of colorectal cancer in clinical practice. Gastroenterology. 1997;112:17–23.
Winawer SJ, Zauber AG, O’Brien MJ, et al. Randomized comparison of surveillance intervals after colonoscopic removal of newly diagnosed adenomatous polyps. N Engl J Med. 1993;328:901–6.
Winawer SJ, Zauber AG, Ho MN, et al. Prevention of colorectal cancer by colonoscopic polypectomy. N Engl J Med. 1993;329:1977–81.
Bressler B, Paszat LF, Vinden C, et al. Colonoscopic miss rates for right-sided colon cancer: a population-based analysis. Gastroenterology. 2004;127:452–6.
Singh H, Nugent Z, Demers AA, et al. The reduction in colorectal cancer mortality after colonoscopy varies by site of the cancer. Gastroenterology. 2010;139:1128–37.
Lasisi F, Rex DK. Improving protection against proximal colon cancer by colonoscopy. Expert Rev Gastroenterol Hepatol. 2011;5:745–54.
Horiuchi A, Nakayama Y. Improved colorectal adenoma detection with a transparent retractable extension device. Am J Gastroenterol. 2008;103:341–5.
Horiuchi A, Nakayama Y, Kato N, et al. Hood-assisted colonoscopy is more effective in detection of colorectal adenomas than narrow band-imaging. Clin Gastroenterol Hepatol. 2010;8:379–83.
Horiuchi A, Nakayama Y, Kajiyama M, et al. Benefits and limitations of cap-fitted colonoscopy in screening colonoscopy. Dig Dis Sci. 2013;58:534–9.
Tsuji S, Horiuchi A, Tamaki M, et al. Effectiveness and safety of a new regimen of polyethylene glycol plus ascorbic acid for same-day bowel cleansing in constipated patients. Acta Gastroenterologica Belgi. 2018;81:485–9.
Sato M, Horiuchi A, Tamaki M, et al. Safety and effectiveness of nurse-administered propofol sedation in outpatients undergoing gastrointestinal endoscopy. Clin Gastroenterol Hepatol. 2019;17:1098–1104.e1.
Participants in the Paris Workshop. The Paris endoscopic classification of superficial neoplastic lesions. Gastrointest Endosc. 2003;58:S3–S43.
Hamilton SR, Aaltonen LA (eds.). World Health Organization Classification of Tumours. Pathology and Genetics of Tumours of the Digestive System, 2nd ed. Lyon, France: IARC Press. 2000.
Leung WK, Lau JY, Suen BY, et al. Repeat-screening colonoscopy 5 years after normal baseline-screening colonoscopy in average-risk Chinese: a prospective study. Am J Gastroenterol. 2009;104:2028–34.
Frieling T, Neuhaus F, Heise J, et al. Cap-assisted colonoscopy (CAC) significantly extends visualization in the right colon. Z Gastroenterol. 2012;50:279–84.
Tada M, Inoue H, Yabata E, et al. Feasibility of the transparent cap-fitted colonoscope for screening and mucosal resection. Dis Colon Rectum. 1997;40:618–21.
Kim HH, Park SJ, Park MI, et al. Transparent-cap-fitted colonoscopy shows higher performance with cecal intubation time in difficult cases. World J Gastroenterol. 2012;18:1953–8.
Facciorusso A, Prete VD, Buccino VR, et al. Comparative efficacy of colonoscope distal attachment devices in increasing rates of adenoma detection: a network meta-analysis. Clin Gastroenterol Hepatol. 2018;16:1209–1219.e9.
Ramai D, Singh J, Brooks OW, et al. Comparison of left versus right lateral starting position on colonoscopy: a systematic review and meta-analysis of randomized controlled trials. Ann Gastroenterol. 2021;34:699–704.
Watanabe J, Park D, Kakehi E, et al. Efficacy and safety of the starting position during colonoscopy: a systematic review and meta-analysis. Endosc Int Open. 2020;08:E848–60.
Lin SY, Yaow CYL, Ng CH, et al. Different position from traditional left lateral for colonoscopy? A meta-analysis and systematic review of randomized control trials. Chronic Dis Transl Med. 2020;7:27–34.
Ghosh S, Iacucci M. Dynamic position change at colonoscopy improves adenoma detection. Canadian J Gastroenterol. 2013;27:508.
Nutalapati V, Desai M, Thoguluva-Chandrasekar VS, et al. Effect of dynamic position changes on adenoma detection rate during colonoscope withdrawal: systematic review and meta-analysis. Endosc Int Open. 2020;8:E1842–9.