Intramodule pressure profiles and protein accumulation during tangential flow filtration.
confocal laser scanning microscopy (CLSM)
gel layer
monoclonal antibody
protein deposition
tangential flow filtration
Journal
Biotechnology progress
ISSN: 1520-6033
Titre abrégé: Biotechnol Prog
Pays: United States
ID NLM: 8506292
Informations de publication
Date de publication:
25 Sep 2023
25 Sep 2023
Historique:
revised:
24
07
2023
received:
09
03
2023
accepted:
03
09
2023
pubmed:
25
9
2023
medline:
25
9
2023
entrez:
25
9
2023
Statut:
aheadofprint
Résumé
Tangential flow filtration (TFF) through a 30 kDa nominal molecular weight cut-off (MWCO) ultrafiltration membrane is widely employed to concentrate purified monoclonal antibodies (mAbs) to levels required for their formulation into injectable biologics. While TFF has been used to remove casein from milk for cheese production for over 35 years, and in pharmaceutical manufacture of biotherapeutic proteins for 20 years, the rapid decline in filtration rate (i.e., flux) at high protein concentrations is a limitation that still needs to be addressed. This is particularly important for mAbs, many of which are 140-160 kDa immunoglobulin G (IgG) type proteins recovered at concentrations of 200 mg/mL or higher. This work reports the direct measurement of local transmembrane pressure drops and off-line confocal imaging of protein accumulation in stagnant regions on the surface of a 30 kDa regenerated cellulose membrane in a flat-sheet configuration widely used in manufacture of biotherapeutic proteins. These first-of-a-kind measurements using 150 kDa bovine IgG show that while axial pressure decreases by 58 psi across a process membrane cassette, the decrease in transmembrane pressure drop is constant at about 1.2 psi/cm along the 20.7 cm length of the membrane. Confocal laser scanning microscopy of the membrane surface at the completion of runs where retentate protein concentration exceeds 200 mg/mL, shows a 50 μm thick protein layer is uniformly deposited. The localized measurements made possible by the modified membrane system confirm the role of protein deposition on limiting ultrafiltration rate and indicate possible targets for improving membrane performance.
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
e3389Informations de copyright
© 2023 The Authors. Biotechnology Progress published by Wiley Periodicals LLC on behalf of American Institute of Chemical Engineers.
Références
Maruthamuthu MK, Rudge SR, Ardekani AM, Ladisch MR, Verma MS. Process analytical technologies and data analytics for the manufacture of monoclonal antibodies. Trends Biotechnol. 2020;38:1169-1185.
Shire SJ, Shahrokh Z, Liu J. Challenges in the development of high protein concentration formulations. J Pharm Sci. 2004;93:1390-1402.
Chahar DS, Ravindran S, Pisal SS. Monoclonal antibody purification and its progression to commercial scale. Biologicals. 2020;63:1-13.
Shultz JE, Lutz H, Rao S. Quality by design as applied to drug substance formulation using ultrafiltration and diafiltration. In: Jameel F, Hershenson S, Khan MA, Martin-Moe S, eds. Quality by Design for Biopharmaceutical Drug Product Development. E-book. 2015. doi:10.1007/978-1-4939-2316-8
Apgar JR, Tam ASP, Sorm R, et al. Modeling and mitigation of high concentration antibody viscosity through structure-based computer-aided protein design. PLoS One. 2020;15(5):e0232713. doi:10.1371/journal.pone.0232713
Di H, Martin GJO, Sun Q, Xie D, Dunstan DE. Detailed, real-time characterization of particle deposition during crossflow filtration as influenced by solution properties. J Membr Sci. 2008;555:115-124.
Ladisch MR. Bioseparations Engineering: Principles, Practice, and Economics. John Wiley and Sons; 2001:55-79.
Cheryan M. Ultrafiltration Handbook. Vol 132-169. Technomic Publishers; 1986:231-243.
Ilias S. A study on concentration polarization in ultrafiltration. Sep Sci Technol. 1993;28:361-381.
Noordman TR, Ketelaar TH, Donkers F, Wesselingh JA. Concentration and desalination of protein solutions by ultrafiltration. Chem Eng Sci. 2002;57:693-703.
Millipore. Protein Concentration and Diafiltration by Tangential Flow Filtration. Merck Millipore; 2003. MILLIPORE_TFF.pdf (huji.ac.il). Accessed Aug 25, 2022.
Shrivastava A, Kumar S, Cussler EL. Predicting the effect of membrane spacers on mass transfer. J Membr Sci. 2008;323:247-256.
Fernandez-Cerezo L, Rayat ACM, Chatel A, Pollard JM, Lye GJ, Hoare M. An ultra-scale-down method to investigate monoclonal antibody processing during tangential flow filtration using ultrafiltration membranes. Biotechnol Bioeng. 2019;116:581-590.
Ngan C, Zou Y, Hillier B, Bartlett A. EMD Millipore Corporation, Billerica, MA (US). High Viscosity TFF Device Design US 2014/0231339 A1, Aug 21, 2014.
Belter PA, Cussler E, Hu W-S. Bioseparations Downstream Processing and Biotechnology. John Wiley and Sons; 1988:22-24 242-247.
Cussler EL. Diffusion Mass Transfer in Fluid Systems. Vol 428-430. Cambridge University Press; 1997:443-449.
Belfort G, Davis R, Zydney A. The behavior of suspensions and macromolecular solutions in crossflow microfiltration, a review for the north American membrane Society's annual reviews and for the. J Membr Sci. 1994;96:1-58.
Schausberger P, Norazman N, Li H, Chen V, Friedl A. Simulation of protein ultrafiltration using CFD: comparison of concentration polarization and fouling effects with filtration and protein adsorption experiments. J Membr Sci. 2009;377:1-8.
Jabra MG, Zydney AL. Design and optimization of single pass tangential flow filtration for inline concentration of monoclonal antibodies. J Membr Sci. 2022;643:120047.
Binabaji E, Ma J, Rao S, Zydney A. Theoretical analysis of the ultrafiltration behavior of highly concentrated protein solutions. J Membr Sci. 2015;494:216-223.
Baek Y, Singh N, Arubkumar A, Zydney A. Ultrafiltration behavior of an fc-fusion protein: filtrate flux data and modeling. J Membr Sci. 2017;528:171-177.
Ferrando M, Zator ARM, López F, Güell C. An approach to membrane fouling characterization by confocal scanning laser microscopy. J Membr Sci. 2005;250:283-293.
Zator M, Warczok J, Ferrando M, López F, Güell C. Chemical cleaning of polycarbonate membranes fouled by BSA/dextran mixtures. J Membr Sci. 2009;327:59-68.
Marroquin M, Vu A, Bruce T, Ranil Wickramasinghe S, Zhao L, Husson SM. Evaluation of fouling mechanisms in asymmetric microfiltration membranes using advanced imaging. J Membr Sci. 2014;465:1-13.
Molecular probes by life technologies. Alexa Fluor®, Pacific Blue™, and Pacific Orange™ Antibody Labeling Kits.
Millipore. Installation and user guide. Pellicon® 3 cassettes. Millipore Sigma. pellicon3-installation-ug-an1065en-ms.pdf (sigmaaldrich.com). Accessed May 30, 2021.
Rossi F, Cunha F, Ximenes E, Bowes B, Yu Z, Yang D, Qian K, Moomaw J, Corvari V, Ladisch M, Reklaitis G. Deterministic mathematical modeling, sensitivity analysis, and dynamic optimization of cross-flow ultrafiltration systems for concentration of monoclonal antibody solution.