Comparison of the Accuracy of a Mounting Fixture for Dental Implants for Implant Position Transfer and Open-Tray Implant Level Impression-An In Vitro Study.

implant impression implant position transfer prosthetic restoration on implants

Journal

Dentistry journal
ISSN: 2304-6767
Titre abrégé: Dent J (Basel)
Pays: Switzerland
ID NLM: 101716125

Informations de publication

Date de publication:
31 Aug 2023
Historique:
received: 22 06 2023
revised: 11 08 2023
accepted: 25 08 2023
medline: 27 9 2023
pubmed: 27 9 2023
entrez: 27 9 2023
Statut: epublish

Résumé

The accuracy for the implant position transfer of a mounting fixture and a standardized open-tray implant level impression was compared. Ten aluminum master models with four implant analogs placed in different angulations were fabricated. By performing an open-tray implant level impression stone casts were produced. The master models and stone casts were scanned (comparison group one) using a laboratory scanner. Deviations in the scan body surface were determined in the form of mean (absolute) point distances and (signed) surface distances. The same procedure was performed with a screwed transfer and by fixing the posts of the mounting fixture (comparison group two). The mounting device was applied to each master model and scanned in a fixed and detached state (comparison group three). In a point comparison, the open-tray implant level impression showed mean deviations of 43.6 µm and a mounting fixture of 44.6 µm with no significant differences (

Identifiants

pubmed: 37754328
pii: dj11090208
doi: 10.3390/dj11090208
pmc: PMC10529300
pii:
doi:

Types de publication

Journal Article

Langues

eng

Références

J Prosthodont. 2019 Feb;28(2):e530-e535
pubmed: 29717518
Clin Implant Dent Relat Res. 2015 Oct;17 Suppl 2:e751-64
pubmed: 25828851
J Dent (Shiraz). 2013 Sep;14(3):96-102
pubmed: 24724130
Niger J Clin Pract. 2013 Jul-Sep;16(3):279-84
pubmed: 23771446
Quintessence Int. 2018;49(4):279-286
pubmed: 29435519
J Adv Prosthodont. 2018 Aug;10(4):265-270
pubmed: 30140392
J Prosthet Dent. 2015 Oct;114(4):517-23
pubmed: 26213265
Int J Dent. 2018 Jun 04;2018:3761750
pubmed: 29971107
Int J Oral Maxillofac Implants. 2014 Jul-Aug;29(4):836-45
pubmed: 25032763
J Prosthet Dent. 2008 Oct;100(4):285-91
pubmed: 18922257
Implant Dent. 2010 Apr;19(2):167-74
pubmed: 20386220
Clin Oral Implants Res. 1992 Mar;3(1):9-16
pubmed: 1420727
Ann Anat. 2012 Mar 20;194(2):185-9
pubmed: 22074678
Eur Oral Res. 2021 May 04;55(2):54-59
pubmed: 34250470
Clin Oral Implants Res. 1999 Oct;10(5):339-45
pubmed: 10551058
Implant Dent. 2015 Dec;24(6):726-9
pubmed: 26384100
Int J Implant Dent. 2018 Mar 20;4(1):9
pubmed: 29556841
Quintessence Int. 2014 Jan;45(1):39-51
pubmed: 24392494
J Prosthet Dent. 2017 Jul;118(1):36-42
pubmed: 28024822
Int J Prosthodont. 2018 Mar/Apr;31(2):171-175
pubmed: 29518813
J Contemp Dent Pract. 2021 Feb 1;22(2):172-178
pubmed: 34257178
Int J Implant Dent. 2019 Feb 19;5(1):4
pubmed: 30778790
Semin Ultrasound CT MR. 2015 Oct;36(5):427-33
pubmed: 26589696
Acta Odontol Scand. 1963 Jun;21:227-54
pubmed: 14042472
Int J Oral Maxillofac Implants. 2017 Jun 14;32(4):792–799
pubmed: 28618432
Implant Dent. 2013 Jun;22(3):268-76
pubmed: 23615660
J Clin Exp Dent. 2018 Apr 01;10(4):e388-e395
pubmed: 29750102
J Clin Exp Dent. 2018 Nov 01;10(11):e1096-e1102
pubmed: 30607227
J Prosthet Dent. 1997 Mar;77(3):235-8
pubmed: 9069076
J Prosthet Dent. 2007 Jun;97(6):349-56
pubmed: 17618917
Materials (Basel). 2019 Oct 21;12(20):
pubmed: 31640243

Auteurs

Alexander Becker (A)

Department of Prosthetic Dentistry and Biomaterials, University of Muenster, D-48149 Münster, Germany.

Dieter Dirksen (D)

Department of Prosthetic Dentistry and Biomaterials, University of Muenster, D-48149 Münster, Germany.

Christoph Runte (C)

Department of Prosthetic Dentistry and Biomaterials, University of Muenster, D-48149 Münster, Germany.

Classifications MeSH