Failure Analysis for Gold Wire Bonding of Sensor Packaging Based on Experimental and Numerical Methods.

failure mechanism and reliability wire bonding wire pull and shear test

Journal

Micromachines
ISSN: 2072-666X
Titre abrégé: Micromachines (Basel)
Pays: Switzerland
ID NLM: 101640903

Informations de publication

Date de publication:
30 Aug 2023
Historique:
received: 29 06 2023
revised: 26 08 2023
accepted: 29 08 2023
medline: 28 9 2023
pubmed: 28 9 2023
entrez: 28 9 2023
Statut: epublish

Résumé

There is an increasing demand for the use of automotive sensors where complex working environments may easily lead to failure. Wire pull and shear test models based on finite-element analysis are established to evaluate their reliability by investigating the failure mode and mechanism of gold wire bonding. The effect of shear force position and pull force position on failure is also analyzed. The bonding failure was verified by experiments, which is consistent with the simulation result. The results show that: (1) The three-dimensional quantitative modeling reveals the process of bonding delamination and stress concentration. (2) The bonding-slip method (BSM) is adopted in the gold ball detaching process. The concept of three states, including deformation accumulation, cracking, and disengagement, was put forward to reveal the interface stress evolution trend according to the shear testing results. The results indicate that in the interface, the stress in the deformation accumulation state decreases from the tensile side (or compression side) to the center, and the stress in the cracking and disengagement states reduces gradually from the tensile side to the edge. When the interface is completely separated, the failed shear force concentrates on 42 g. The concept and theory proposed in this work can effectively reveal the failure mechanism of bonding interface and help to establish a new failure criterion.

Identifiants

pubmed: 37763858
pii: mi14091695
doi: 10.3390/mi14091695
pmc: PMC10535198
pii:
doi:

Types de publication

Journal Article

Langues

eng

Subventions

Organisme : the National Key R&D Program of China
ID : 2022YFB3207100
Organisme : the Hubei Provincial Strategic Scientist Training Plan
ID : 2022EJD009
Organisme : the Fundamental Research Funds for the Central Universities
ID : 2042023kf1041

Références

Sensors (Basel). 2012;12(1):806-38
pubmed: 22368497
Sensors (Basel). 2018 Jun 21;18(7):
pubmed: 29933568
Spinal Cord. 2021 Jun;59(6):675-683
pubmed: 33024297
Sensors (Basel). 2021 May 05;21(9):
pubmed: 34062979

Auteurs

Yameng Sun (Y)

Laboratory for Electronic Manufacturing and Packaging Integration, The Institute of Technological Sciences, Wuhan University, Wuhan 430070, China.

Kun Ma (K)

Laboratory for Electronic Manufacturing and Packaging Integration, The Institute of Technological Sciences, Wuhan University, Wuhan 430070, China.

Yifan Song (Y)

School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430070, China.

Tongtong Zi (T)

Hefei Archimedes Electronic Technology Co., Ltd., Hefei 230000, China.

Xun Liu (X)

Laboratory for Electronic Manufacturing and Packaging Integration, The Institute of Technological Sciences, Wuhan University, Wuhan 430070, China.

Zheng Feng (Z)

Hefei Archimedes Electronic Technology Co., Ltd., Hefei 230000, China.

Yang Zhou (Y)

Hefei Archimedes Electronic Technology Co., Ltd., Hefei 230000, China.

Sheng Liu (S)

Laboratory for Electronic Manufacturing and Packaging Integration, The Institute of Technological Sciences, Wuhan University, Wuhan 430070, China.
School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430070, China.
Hefei Archimedes Electronic Technology Co., Ltd., Hefei 230000, China.
School of Power and Mechanical Engineering, Wuhan University, Wuhan 430070, China.

Classifications MeSH