Nocturnal Blood Pressure Estimation from Sleep Plethysmography Using Machine Learning.
blood pressure estimation
cardiovascular health
cuffless blood pressure measurement
nocturnal blood pressure
photoplethysmography
sleep
Journal
Sensors (Basel, Switzerland)
ISSN: 1424-8220
Titre abrégé: Sensors (Basel)
Pays: Switzerland
ID NLM: 101204366
Informations de publication
Date de publication:
16 Sep 2023
16 Sep 2023
Historique:
received:
27
08
2023
revised:
11
09
2023
accepted:
12
09
2023
medline:
29
9
2023
pubmed:
28
9
2023
entrez:
28
9
2023
Statut:
epublish
Résumé
Elevated nocturnal blood pressure (BP) is a risk factor for cardiovascular disease (CVD) and mortality. Cuffless BP assessment aided by machine learning could be a desirable alternative to traditional cuff-based methods for monitoring BP during sleep. We describe a machine-learning-based algorithm for predicting nocturnal BP using single-channel fingertip plethysmography (PPG) in healthy adults. Sixty-eight healthy adults with no apparent sleep or CVD (53% male), with a median (IQR) age of 29 (23-46 years), underwent overnight polysomnography (PSG) with fingertip PPG and ambulatory blood pressure monitoring (ABPM). Features based on pulse morphology were extracted from the PPG waveforms. Random forest models were used to predict night-time systolic blood pressure (SBP) and diastolic blood pressure (DBP). Our model achieved the highest out-of-sample performance with a window length of 7 s across window lengths explored (60 s, 30 s, 15 s, 7 s, and 3 s). The mean absolute error (MAE ± STD) was 5.72 ± 4.51 mmHg for SBP and 4.52 ± 3.60 mmHg for DBP. Similarly, the root mean square error (RMSE ± STD) was 6.47 ± 1.88 mmHg for SBP and 4.62 ± 1.17 mmHg for DBP. The mean correlation coefficient between measured and predicted values was 0.87 for SBP and 0.86 for DBP. Based on Shapley additive explanation (SHAP) values, the most important PPG waveform feature was the stiffness index, a marker that reflects the change in arterial stiffness. Our results highlight the potential of machine learning-based nocturnal BP prediction using single-channel fingertip PPG in healthy adults. The accuracy of the predictions demonstrated that our cuffless method was able to capture the dynamic and complex relationship between PPG waveform characteristics and BP during sleep, which may provide a scalable, convenient, economical, and non-invasive means to continuously monitor blood pressure.
Sections du résumé
BACKGROUND
BACKGROUND
Elevated nocturnal blood pressure (BP) is a risk factor for cardiovascular disease (CVD) and mortality. Cuffless BP assessment aided by machine learning could be a desirable alternative to traditional cuff-based methods for monitoring BP during sleep. We describe a machine-learning-based algorithm for predicting nocturnal BP using single-channel fingertip plethysmography (PPG) in healthy adults.
METHODS
METHODS
Sixty-eight healthy adults with no apparent sleep or CVD (53% male), with a median (IQR) age of 29 (23-46 years), underwent overnight polysomnography (PSG) with fingertip PPG and ambulatory blood pressure monitoring (ABPM). Features based on pulse morphology were extracted from the PPG waveforms. Random forest models were used to predict night-time systolic blood pressure (SBP) and diastolic blood pressure (DBP).
RESULTS
RESULTS
Our model achieved the highest out-of-sample performance with a window length of 7 s across window lengths explored (60 s, 30 s, 15 s, 7 s, and 3 s). The mean absolute error (MAE ± STD) was 5.72 ± 4.51 mmHg for SBP and 4.52 ± 3.60 mmHg for DBP. Similarly, the root mean square error (RMSE ± STD) was 6.47 ± 1.88 mmHg for SBP and 4.62 ± 1.17 mmHg for DBP. The mean correlation coefficient between measured and predicted values was 0.87 for SBP and 0.86 for DBP. Based on Shapley additive explanation (SHAP) values, the most important PPG waveform feature was the stiffness index, a marker that reflects the change in arterial stiffness.
CONCLUSION
CONCLUSIONS
Our results highlight the potential of machine learning-based nocturnal BP prediction using single-channel fingertip PPG in healthy adults. The accuracy of the predictions demonstrated that our cuffless method was able to capture the dynamic and complex relationship between PPG waveform characteristics and BP during sleep, which may provide a scalable, convenient, economical, and non-invasive means to continuously monitor blood pressure.
Identifiants
pubmed: 37765988
pii: s23187931
doi: 10.3390/s23187931
pmc: PMC10537552
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Subventions
Organisme : NIMH NIH HHS
ID : R01 MH120080
Pays : United States
Organisme : NIMH NIH HHS
ID : R01 MH133334
Pays : United States
Références
IEEE Trans Biomed Eng. 2015 Aug;62(8):1879-901
pubmed: 26057530
Comput Biol Med. 2019 Oct;113:103392
pubmed: 31446317
Artif Intell Med. 2011 Oct;53(2):127-38
pubmed: 21696930
Am J Hypertens. 2022 May 10;35(5):407-413
pubmed: 35171213
Sci Rep. 2021 Oct 19;11(1):20644
pubmed: 34667230
Blood Press Monit. 2020 Apr;25(2):110-114
pubmed: 31833949
Hypertension. 2021 Nov;78(5):1161-1167
pubmed: 34510915
Eur Heart J. 2018 Sep 1;39(33):3021-3104
pubmed: 30165516
Annu Int Conf IEEE Eng Med Biol Soc. 2012;2012:3951-4
pubmed: 23366792
Am J Physiol Heart Circ Physiol. 2022 Apr 1;322(4):H493-H522
pubmed: 34951543
Clin Sci (Lond). 2002 Oct;103(4):371-7
pubmed: 12241535
J Clin Med. 2018 Sep 30;7(10):
pubmed: 30274376
Annu Int Conf IEEE Eng Med Biol Soc. 2018 Jul;2018:5002-5005
pubmed: 30441464
Sleep. 2010 Dec;33(12):1687-92
pubmed: 21120131
Physiol Meas. 2018 Oct 11;39(10):105004
pubmed: 30199376
J Hypertens. 2016 Dec;34(12):2427-2433
pubmed: 27607460
Sleep. 2023 Jun 28;:
pubmed: 37379483
J Sleep Res. 2018 Apr;27(2):259-267
pubmed: 28901049
Eur Heart J. 2018 Dec 14;39(47):4159-4171
pubmed: 30107515
NPJ Digit Med. 2019 Jun 26;2:60
pubmed: 31388564
Physiol Meas. 2020 May 07;41(4):044003
pubmed: 32143197
J Am Coll Cardiol. 1999 Dec;34(7):2007-14
pubmed: 10588217
Anesthesiology. 2015 Aug;123(2):336-45
pubmed: 26035252
Sensors (Basel). 2020 Oct 04;20(19):
pubmed: 33020401
Physiol Meas. 2020 Aug 11;41(7):074001
pubmed: 32784270
Physiol Meas. 2019 Feb 26;40(2):025006
pubmed: 30699397
Sci Rep. 2023 Jan 18;13(1):986
pubmed: 36653426
JAMA. 2019 Aug 6;322(5):409-420
pubmed: 31386134
Sleep. 1991 Dec;14(6):540-5
pubmed: 1798888
Hypertens Res. 2012 Jul;35(7):695-701
pubmed: 22378470
Lancet. 2017 Jan 7;389(10064):37-55
pubmed: 27863813
Sleep. 2020 Jul 13;43(7):
pubmed: 31978212
Front Psychol. 2017 Apr 07;8:456
pubmed: 28439244
Curr Cardiol Rev. 2012 Feb;8(1):14-25
pubmed: 22845812
Hypertension. 2018 Jun;71(6):1269-1324
pubmed: 29133354
IEEE Trans Biomed Eng. 2014 Jul;61(7):2179-86
pubmed: 24760899
Hypertension. 2018 Jun;71(6):997-1009
pubmed: 29712746
Sensors (Basel). 2020 Jun 01;20(11):
pubmed: 32492902