Characterization of durability and reconnection patterns at time of repeat ablation after single-shot pulsed field pulmonary vein isolation.

Arrhythmia recurrence Atrial fibrillation Durability Electrophysiology Mapping Pulsed field ablation Reconduction Reconnection Ultra-high density

Journal

Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing
ISSN: 1572-8595
Titre abrégé: J Interv Card Electrophysiol
Pays: Netherlands
ID NLM: 9708966

Informations de publication

Date de publication:
30 Sep 2023
Historique:
received: 02 08 2023
accepted: 17 09 2023
medline: 1 10 2023
pubmed: 1 10 2023
entrez: 30 9 2023
Statut: aheadofprint

Résumé

Pulsed field ablation (PFA) is a novel method of cardiac ablation where there is insufficient knowledge on the durability and reconnection patterns after pulmonary vein isolation (PVI). The aim of this study was to characterize the electrophysiological findings at time of repeat procedure in real-world atrial fibrillation (AF) patients. Patients who underwent a repeat procedure (n=26) for symptomatic recurrent arrhythmias after index first-time treatment with single-shot PFA PVI (n=266) from July 2021 to June 2023 were investigated with 3D high-density mapping and ad-hoc re-ablation by radiofrequency or focal PFA. Index indication for PVI was persistent AF in 17 (65%) patients. The mean time to repeat procedure was 292 ± 119 days. Of the 26 patients (104 veins), complete durable PVI was observed in 11/26 (42%) with a durable vein isolation rate of 72/104 (69%). Two patients (8%) had all four veins reconnected. The posterior wall was durably isolated in 4/5 (80%) of the cases. The predominant arrhythmia mechanism was AF in 17/26 (65%) patients and regular atrial tachycardia (AT) in 9/26 (35%). Reconnection was observed 9/26 (35%) in right superior, 11/26 (42%) in right inferior, 7/26 (27%) in left superior, 5/26 (19%) in left inferior, p=0.31 between veins. The gaps were significantly clustered in the right-sided anterior carina compared to other regions (P=0.009). Durable PVI was observed in less than half of the patients at time of repeat procedure. No significant difference in PV reconnection pattern was observed, but the gap location was preferentially located at the anterior aspects of the right-sided PVs. Predominant recurrence was AF. More data is needed to establish lesion formation and durability and AT circuits after PFA.

Sections du résumé

BACKGROUND BACKGROUND
Pulsed field ablation (PFA) is a novel method of cardiac ablation where there is insufficient knowledge on the durability and reconnection patterns after pulmonary vein isolation (PVI). The aim of this study was to characterize the electrophysiological findings at time of repeat procedure in real-world atrial fibrillation (AF) patients.
METHODS METHODS
Patients who underwent a repeat procedure (n=26) for symptomatic recurrent arrhythmias after index first-time treatment with single-shot PFA PVI (n=266) from July 2021 to June 2023 were investigated with 3D high-density mapping and ad-hoc re-ablation by radiofrequency or focal PFA.
RESULTS RESULTS
Index indication for PVI was persistent AF in 17 (65%) patients. The mean time to repeat procedure was 292 ± 119 days. Of the 26 patients (104 veins), complete durable PVI was observed in 11/26 (42%) with a durable vein isolation rate of 72/104 (69%). Two patients (8%) had all four veins reconnected. The posterior wall was durably isolated in 4/5 (80%) of the cases. The predominant arrhythmia mechanism was AF in 17/26 (65%) patients and regular atrial tachycardia (AT) in 9/26 (35%). Reconnection was observed 9/26 (35%) in right superior, 11/26 (42%) in right inferior, 7/26 (27%) in left superior, 5/26 (19%) in left inferior, p=0.31 between veins. The gaps were significantly clustered in the right-sided anterior carina compared to other regions (P=0.009).
CONCLUSIONS CONCLUSIONS
Durable PVI was observed in less than half of the patients at time of repeat procedure. No significant difference in PV reconnection pattern was observed, but the gap location was preferentially located at the anterior aspects of the right-sided PVs. Predominant recurrence was AF. More data is needed to establish lesion formation and durability and AT circuits after PFA.

Identifiants

pubmed: 37776356
doi: 10.1007/s10840-023-01655-0
pii: 10.1007/s10840-023-01655-0
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Informations de copyright

© 2023. The Author(s).

Références

Sorensen SK, Johannessen A, Worck R, Hansen ML, Hansen J. Radiofrequency versus cryoballoon catheter ablation for paroxysmal atrial fibrillation: durability of pulmonary vein isolation and effect on atrial fibrillation burden: the RACE-AF randomized controlled trial. Circ Arrhythm Electrophysiol. 2021;14(5):e009573.
doi: 10.1161/CIRCEP.120.009573 pubmed: 33835823 pmcid: 8136462
Neven K, van Es R, van Driel V, van Wessel H, Fidder H, Vink A, et al. Acute and long-term effects of full-power electroporation ablation directly on the porcine esophagus. Circ Arrhythm Electrophysiol. 2017;10(5):e004672. https://doi.org/10.1161/CIRCEP.116.004672 .
Neven K, Futing A, Byrd I, Heil RW Jr, Fish JM, Feeney DA, et al. Absence of (sub-)acute cerebral events or lesions after electroporation ablation in the left-sided canine heart. Heart Rhythm. 2021;18(6):1004–11.
doi: 10.1016/j.hrthm.2021.02.015 pubmed: 33617997
Koruth JS, Kuroki K, Kawamura I, Brose R, Viswanathan R, Buck ED, et al. Pulsed field ablation versus radiofrequency ablation: esophageal injury in a novel porcine model. Circ Arrhythm Electrophysiol. 2020;13(3):e008303.
doi: 10.1161/CIRCEP.119.008303 pubmed: 31977250 pmcid: 7069397
Reddy VY, Dukkipati SR, Neuzil P, Anic A, Petru J, Funasako M, et al. Pulsed field ablation of paroxysmal atrial fibrillation: 1-year outcomes of IMPULSE, PEFCAT, and PEFCAT II. JACC Clin Electrophysiol. 2021;7(5):614–27.
doi: 10.1016/j.jacep.2021.02.014 pubmed: 33933412
Reddy VY, Neuzil P, Koruth JS, Petru J, Funosako M, Cochet H, et al. Pulsed field ablation for pulmonary vein isolation in atrial fibrillation. J Am Coll Cardiol. 2019;74(3):315–26.
doi: 10.1016/j.jacc.2019.04.021 pubmed: 31085321
Reddy VY, Anic A, Koruth J, Petru J, Funasako M, Minami K, et al. Pulsed field ablation in patients with persistent atrial fibrillation. J Am Coll Cardiol. 2020;76(9):1068–80.
doi: 10.1016/j.jacc.2020.07.007 pubmed: 32854842
Turagam MK, Neuzil P, Schmidt B, Reichlin T, Neven K, Metzner A, et al. Safety and effectiveness of pulsed field ablation to treat atrial fibrillation: one-year outcomes from the MANIFEST-PF Registry. Circulation. 2023;148(1):35–46. https://doi.org/10.1161/CIRCULATIONAHA.123.064959 .
doi: 10.1161/CIRCULATIONAHA.123.064959 pubmed: 37199171
Ekanem E, Reddy VY, Schmidt B, Reichlin T, Neven K, Metzner A, et al. Multi-national survey on the methods, efficacy, and safety on the post-approval clinical use of pulsed field ablation (MANIFEST-PF). Europace. 2022;24(8):1256–66.
doi: 10.1093/europace/euac050 pubmed: 35647644 pmcid: 9435639
Ruwald MH, Johannessen A, Hansen ML, Haugdal M, Worck R, Hansen J. Pulsed field ablation in real-world atrial fibrillation patients: clinical recurrence, operator learning curve and re-do procedural findings. J Interv Card Electrophysiol. 2023. https://doi.org/10.1007/s10840-023-01495-y .
doi: 10.1007/s10840-023-01495-y pubmed: 37249807
Schmidt B, Bordignon S, Tohoku S, Chen S, Bologna F, Urbanek L, et al. 5S study: safe and simple single shot pulmonary vein isolation with pulsed field ablation using sedation. Circ Arrhythm Electrophysiol. 2022;15(6):e010817.
doi: 10.1161/CIRCEP.121.010817 pubmed: 35617232
Magni FT, Mulder BA, Groenveld HF, Wiesfeld ACP, Tieleman RG, Cox MG, et al. Initial experience with pulsed field ablation for atrial fibrillation. Front Cardiovasc Med. 2022;9:959186.
doi: 10.3389/fcvm.2022.959186 pubmed: 36426226 pmcid: 9679623
Futing A, Reinsch N, Howel D, Brokkaar L, Rahe G, Neven K. First experience with pulsed field ablation as routine treatment for paroxysmal atrial fibrillation. Europace. 2022;24(7):1084–92.
doi: 10.1093/europace/euac041 pubmed: 35513354
Tohoku S, Chun KRJ, Bordignon S, Chen S, Schaack D, Urbanek L, et al. Findings from repeat ablation using high-density mapping after pulmonary vein isolation with pulsed field ablation. Europace. 2023;25(2):433–40.
doi: 10.1093/europace/euac211 pubmed: 36427201
Ruwald MH, Johannessen A, Hansen ML, Haugdal M, Worck R, Hansen J. Utility of high-density 3D-bipolar voltage map after pulmonary vein isolation by pulsed-field ablation. JACC Clin Electrophysiol. 2023;9(4):588–90.
doi: 10.1016/j.jacep.2022.11.030 pubmed: 36752456
Vicera JJB, Lin YJ, Lee PT, Chang SL, Lo LW, Hu YF, et al. Identification of critical isthmus using coherent mapping in patients with scar-related atrial tachycardia. J Cardiovasc Electrophysiol. 2020;31(6):1436–47.
doi: 10.1111/jce.14457 pubmed: 32227530 pmcid: 7383970
Ruwald MH, Johannessen A, Hansen ML, Worck R, Hansen J. Pulsed field ablation of the cavotricuspid isthmus using a multispline-electrode pulsed field ablation catheter. HeartRhythm Case Rep. 2022;8(3):147–50.
doi: 10.1016/j.hrcr.2021.12.009 pubmed: 35492844
Duytschaever M, De Pooter J, Demolder A, El Haddad M, Phlips T, Strisciuglio T, et al. Long-term impact of catheter ablation on arrhythmia burden in low-risk patients with paroxysmal atrial fibrillation: the CLOSE to CURE study. Heart Rhythm. 2020;17(4):535–43.
doi: 10.1016/j.hrthm.2019.11.004 pubmed: 31707159
Ruwald MH, Johannessen A, Hansen ML, Haugdal M, Worck R, Hansen J. Focal pulsed field ablation and ultrahigh-density mapping - versatile tools for all atrial arrhythmias? Initial procedural experiences. J Interv Card Electrophysiol. 2023. https://doi.org/10.1007/s10840-023-01570-4 .
doi: 10.1007/s10840-023-01570-4 pubmed: 37249807
Sorensen SK, Johannessen A, Worck R, Hansen ML, Ruwald MH, Hansen J. Differential gap location after radiofrequency versus cryoballoon pulmonary vein isolation: insights from a randomized trial with protocol-mandated repeat procedure. J Cardiovasc Electrophysiol. 2023;34(3):519–26.
doi: 10.1111/jce.15821 pubmed: 36640430
Gunawardene MA, Schaeffer BN, Jularic M, Eickholt C, Maurer T, Akbulak RO, et al. Pulsed-field ablation combined with ultrahigh-density mapping in patients undergoing catheter ablation for atrial fibrillation: practical and electrophysiological considerations. J Cardiovasc Electrophysiol. 2022;33(3):345–56.
doi: 10.1111/jce.15349 pubmed: 34978360
Lemoine MD, Fink T, Mencke C, Schleberger R, My I, Obergassel J, et al. Pulsed-field ablation-based pulmonary vein isolation: acute safety, efficacy and short-term follow-up in a multi-center real world scenario. Clin Res Cardiol. 2022; https://doi.org/10.1007/s00392-022-02091-2 .
Kiuchi K, Kircher S, Watanabe N, Gaspar T, Rolf S, Arya A, et al. Quantitative analysis of isolation area and rhythm outcome in patients with paroxysmal atrial fibrillation after circumferential pulmonary vein antrum isolation using the pace-and-ablate technique. Circ Arrhythm Electrophysiol. 2012;5(4):667–75.
doi: 10.1161/CIRCEP.111.969923 pubmed: 22752925
Ouyang F, Antz M, Ernst S, Hachiya H, Mavrakis H, Deger FT, et al. Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: lessons from double Lasso technique. Circulation. 2005;111(2):127–35.
doi: 10.1161/01.CIR.0000151289.73085.36 pubmed: 15623542
Hussein A, Das M, Riva S, Morgan M, Ronayne C, Sahni A, et al. Use of ablation index-guided ablation results in high rates of durable pulmonary vein isolation and freedom from arrhythmia in persistent atrial fibrillation patients: the PRAISE study results. Circ Arrhythm Electrophysiol. 2018;11(9):e006576.
doi: 10.1161/CIRCEP.118.006576 pubmed: 30354288
Das M, Wynn GJ, Saeed Y, Gomes S, Morgan M, Ronayne C, et al. Pulmonary vein re-isolation as a routine strategy regardless of symptoms: the PRESSURE randomized controlled trial. JACC Clin Electrophysiol. 2017;3(6):602–11.
doi: 10.1016/j.jacep.2017.01.016 pubmed: 29759434
Miyazaki S, Taniguchi H, Hachiya H, Nakamura H, Takagi T, Iwasawa J, et al. Quantitative analysis of the isolation area during the chronic phase after a 28-mm second-generation cryoballoon ablation demarcated by high-resolution electroanatomic mapping. Circ Arrhythm Electrophysiol. 2016;9(5):e003879.
doi: 10.1161/CIRCEP.115.003879 pubmed: 27146418
Reddy VY, Sediva L, Petru J, Skoda J, Chovanec M, Chitovova Z, et al. Durability of pulmonary vein isolation with cryoballoon ablation: results from the Sustained PV Isolation with Arctic Front Advance (SUPIR) study. J Cardiovasc Electrophysiol. 2015;26(5):493–500.
doi: 10.1111/jce.12626 pubmed: 25644659
Kuck KH, Albenque JP, Chun KJ, Furnkranz A, Busch M, Elvan A, et al. Repeat ablation for atrial fibrillation recurrence post cryoballoon or radiofrequency ablation in the FIRE AND ICE trial. Circ Arrhythm Electrophysiol. 2019;12(6):e007247.
doi: 10.1161/CIRCEP.119.007247 pubmed: 31693319
Cheung CC, Deyell MW, Macle L, Verma A, Champagne J, Leong-Sit P, et al. Repeat atrial fibrillation ablation procedures in the CIRCA-DOSE study. Circ Arrhythm Electrophysiol. 2020;13(9):e008480.
doi: 10.1161/CIRCEP.120.008480 pubmed: 32701361
De Pooter J, Strisciuglio T, El Haddad M, Wolf M, Phlips T, Vandekerckhove Y, et al. Pulmonary vein reconnection no longer occurs in the majority of patients after a single pulmonary vein isolation procedure. JACC Clin Electrophysiol. 2019;5(3):295–305.
doi: 10.1016/j.jacep.2018.11.020 pubmed: 30898231
Andrade JG, Champagne J, Dubuc M, Deyell MW, Verma A, Macle L, et al. Cryoballoon or radiofrequency ablation for atrial fibrillation assessed by continuous monitoring: a randomized clinical trial. Circulation. 2019;140(22):1779–88.
doi: 10.1161/CIRCULATIONAHA.119.042622 pubmed: 31630538
Andrade JG, Deyell MW, Verma A, Macle L, Khairy P. The cryoballoon vs irrigated radiofrequency catheter ablation (CIRCA-DOSE) study results in context. Arrhythmia Electrophysiol Rev. 2020;9(1):34–9.
doi: 10.15420/aer.2019.13

Auteurs

Martin H Ruwald (MH)

Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark. mruwald@hotmail.com.

Martin Haugdal (M)

Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark.

Rene Worck (R)

Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark.

Arne Johannessen (A)

Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark.

Morten Lock Hansen (ML)

Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark.

Samuel K Sørensen (SK)

Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark.

Jim Hansen (J)

Division of Electrophysiology, Department of Cardiology, Herlev-Gentofte Hospital, Gentofte Hospitalsvej 1, DK-2900, Hellerup, Denmark.

Classifications MeSH