Skeletal muscle extracellular matrix structure under applied deformation observed using second harmonic generation microscopy.


Journal

Acta biomaterialia
ISSN: 1878-7568
Titre abrégé: Acta Biomater
Pays: England
ID NLM: 101233144

Informations de publication

Date de publication:
12 2023
Historique:
received: 03 04 2023
revised: 24 09 2023
accepted: 26 09 2023
medline: 27 11 2023
pubmed: 8 10 2023
entrez: 7 10 2023
Statut: ppublish

Résumé

The mechanical and structural properties of passive skeletal muscle are important for musculoskeletal models in impact biomechanics, rehabilitation engineering and surgical simulation. Passive properties of skeletal muscle depend strongly on the architecture of the extracellular matrix (ECM), but the structure of ECM and its realignment under applied deformation remain poorly understood. We apply second harmonic generation (SHG) microscopy to study muscle ECM in intact muscle samples both under deformation and in the undeformed state. A method for regional relocation was developed, so that the same ECM segment could be viewed before and after applying deformations. Skeletal muscle ECM was viewed at multiple scales and in three states: undeformed, under compression and under tension. Results show that second harmonic generation microscopy provides substantial detail of skeletal muscle ECM over a wide range of length scales, especially the perimysium structure. We present images of individual portions of skeletal muscle ECM both undeformed and subjected to tensile/compressive deformation. We also present data showing the response of the perimysium to a partial thickness cut applied to a section under tensile deformation. STATEMENT OF SIGNIFICANCE: Second Harmonic Generation (SHG) microscopy is an imaging technique which takes advantage of a non-linear and coherent frequency doubling optical effect that is present in a small number of biological molecules, primarily collagen Type I, II and myosin. Collagen I is the most abundant collagen type in skeletal muscle, making SHG a promising option for visualisation of the skeletal muscle extracellular matrix (ECM). SHG microscopy does not require fixing or staining. This short communication presents the application of SHG microscopy to skeletal muscle ECM to improve our understanding of how collagen fibres reorganise under applied tensile and compression, including microscopic observations of collagen fibre reorganisation for intact samples by using a method to re-identify specific regions in repeated deformation tests.

Identifiants

pubmed: 37804951
pii: S1742-7061(23)00593-7
doi: 10.1016/j.actbio.2023.09.047
pii:
doi:

Substances chimiques

Collagen 9007-34-5
Collagen Type I 0

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

135-146

Informations de copyright

Copyright © 2023 The Author(s). Published by Elsevier Ltd.. All rights reserved.

Déclaration de conflit d'intérêts

Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Auteurs

Niamh Hennessy (N)

Trinity Centre for Biomedical Engineering, Department of Mechanical, Manufacturing and Biomedical Engineering, Parsons Building, Trinity College Dublin, College Green, Dublin 2, Ireland. Electronic address: nhenness@tcd.ie.

Ciaran Simms (C)

Trinity Centre for Biomedical Engineering, Department of Mechanical, Manufacturing and Biomedical Engineering, Parsons Building, Trinity College Dublin, College Green, Dublin 2, Ireland.

Articles similaires

Arm muscle area is correlated to handgrip strength in postmenopausal women.

Ludwig R Álvarez-Córdova, Reyes Artacho, Peter Chedraui et al.
1.00
Humans Female Hand Strength Postmenopause Cross-Sectional Studies
Humans Arthroplasty, Replacement, Knee Osteoarthritis, Knee Awards and Prizes Biomechanical Phenomena
Humans Transcranial Magnetic Stimulation Male Cerebellum Evoked Potentials, Motor

Contemporary insights into spinopelvic mechanics.

Andreas Fontalis, Daniel Buchalter, Fabio Mancino et al.
1.00
Humans Biomechanical Phenomena Arthroplasty, Replacement, Hip Spine Hip Prosthesis

Classifications MeSH