Performance of two plasma separation devices for HIV-1 viral load measurement in primary healthcare settings.
HIV-1 viral load
antiretroviral Therapy
primary healthcare
Journal
Microbiology spectrum
ISSN: 2165-0497
Titre abrégé: Microbiol Spectr
Pays: United States
ID NLM: 101634614
Informations de publication
Date de publication:
09 Oct 2023
09 Oct 2023
Historique:
medline:
9
10
2023
pubmed:
9
10
2023
entrez:
9
10
2023
Statut:
aheadofprint
Résumé
Dried blood spot (DBS) may overestimate the viral RNA, mainly in patients with low viral load (VL), due to proviral DNA and intracellular RNA. The Burnett and HemaSpot provide integrated solutions for the collection, separation, and drying of plasma from whole blood. This study aims to evaluate the performance of both devices compared to plasma to identify antiretroviral therapy (ART) failure. The devices were separately evaluated in a cross-sectional design. Patients on ART were included for the studies (Burnett: 611, October 2019 to January 2020) and (HemaSpot: 620, November 2020 to April 2021). VL was tested using CAP/CTM96. The sensitivity and specificity of DBS, Burnett, and HemaSpot were determined, and plasma results were considered as a reference at a threshold of 1,000 copies/ml. For the Burnett study, 2,444 specimens, including plasma, DBS, venous Burnett (vBurnett), and capillary Burnett (cBurnett), were collected. Sensitivity of DBS, vBurnett, and cBurnett was 97.4%, 98.3%, and 97.5%, respectively, whereas specificity was 86.8% for DBS, 96.9% for vBurnett, and 93.9% for cBurnett. For the HemaSpot study, 1,860 specimens were collected, including plasma, DBS, and vHemaSpot. Sensitivity of DBS and vHemaSpot was 95.0% and 91.3%, respectively, whereas specificity was 86.9% for DBS and 94.5% for vHemaSpot. The misclassification rate was more prominent in DBS (4.8%) and HemaSpot (8.4%) but lower in vBurnett (2.0%) and cBurnett (3.2%). The Burnett showed better performance than DBS, whereas HemaSpot showed poorer performance than DBS. Nevertheless, both Burnett and HemaSpot have high rate of non-reportable results. In the current format, neither of the two devices is feasible for VL scale-up in resource-limited settings.IMPORTANCEBurnett and HemaSpot are two novel technologies that allow whole blood collection and plasma separation and stabilization at room temperature without the need of additional equipment. Hence, these devices are potential alternatives to fresh plasma as a suitable specimen for viral load scale-up to monitor antiretroviral therapy in resource-limited settings.
Identifiants
pubmed: 37812011
doi: 10.1128/spectrum.00546-23
pmc: PMC10715000
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
e0054623Références
Lancet. 1986 Feb 8;1(8476):307-10
pubmed: 2868172
Rev Med Virol. 2021 Mar;31(2):e2165
pubmed: 32978882
PLoS One. 2017 Jul 13;12(7):e0181054
pubmed: 28704560
PLoS One. 2014 Mar 06;9(3):e86461
pubmed: 24603442
Am J Clin Pathol. 2022 Jul 1;158(1):13-17
pubmed: 35136911
PLoS One. 2020 May 6;15(5):e0232122
pubmed: 32374748
J Clin Microbiol. 1997 Nov;35(11):2886-93
pubmed: 9350753
J Clin Virol. 2017 Jul;92:56-61
pubmed: 28531553
PDA J Pharm Sci Technol. 1998 Mar-Apr;52(2):55-9
pubmed: 9610168
Clin Infect Dis. 2020 Mar 3;70(6):1014-1020
pubmed: 31321438
J Clin Microbiol. 2012 Apr;50(4):1458-60
pubmed: 22278838
PLoS Med. 2022 Aug 22;19(8):e1004076
pubmed: 35994520
J Clin Microbiol. 2019 Mar 28;57(4):
pubmed: 30728197
S Afr Med J. 2015 Nov 08;105(12):1036-8
pubmed: 26792161
J Clin Microbiol. 2014 Nov;52(11):3878-83
pubmed: 25143579
PLoS One. 2017 Jun 16;12(6):e0179316
pubmed: 28622370
J Virol Methods. 2018 Jan;251:75-79
pubmed: 29038002
J Clin Microbiol. 2019 Mar 28;57(4):
pubmed: 30700508
J Acquir Immune Defic Syndr. 2017 Apr 01;74(4):399-406
pubmed: 28002185