Depth-Imaging for Gait Analysis on a Treadmill in Older Adults at Risk of Falling.


Journal

IEEE journal of translational engineering in health and medicine
ISSN: 2168-2372
Titre abrégé: IEEE J Transl Eng Health Med
Pays: United States
ID NLM: 101623153

Informations de publication

Date de publication:
2023
Historique:
received: 20 10 2022
revised: 05 04 2023
revised: 10 05 2023
accepted: 11 05 2023
medline: 12 10 2023
pubmed: 11 10 2023
entrez: 11 10 2023
Statut: epublish

Résumé

Accidental falls are a major health issue in older people. One significant and potentially modifiable risk factor is reduced gait stability. Clinicians do not have sophisticated kinematic options to measure this risk factor with simple and affordable systems. Depth-imaging with AI-pose estimation can be used for gait analysis in young healthy adults. However, is it applicable for measuring gait in older adults at a risk of falling? In this methodological comparison 59 older adults with and without a history of falls walked on a treadmill while their gait pattern was recorded with multiple inertial measurement units and with an Azure Kinect depth-camera. Spatiotemporal gait parameters of both systems were compared for convergent validity and with a Bland-Altman plot. Correlation between systems for stride length (r=.992, [Formula: see text]) and stride time (r=0.914, [Formula: see text]) was high. Bland-Altman plots revealed a moderate agreement in stride length (-0.74 ± 3.68 cm; [-7.96 cm to 6.47 cm]) and stride time (-3.7±54 ms; [-109 ms to 102 ms]). Gait parameters in older adults with and without a history of falls can be measured with inertial measurement units and Azure Kinect cameras. Affordable and small depth-cameras agree with IMUs for gait analysis in older adults with and without an increased risk of falling. However, tolerable accuracy is limited to the average over multiple steps of spatiotemporal parameters derived from the initial foot contact. Clinical Translation Statement- Gait parameters in older adults with and without a history of falls can be measured with inertial measurement units and Azure Kinect. Affordable and small depth-cameras, developed for various purposes in research and industry, agree with IMUs in clinical gait analysis in older adults with and without an increased risk of falling. However, tolerable accuracy to assess function or monitor changes in gait is limited to the average over multiple steps of spatiotemporal parameters derived from the initial foot contact.

Sections du résumé

BACKGROUND
Accidental falls are a major health issue in older people. One significant and potentially modifiable risk factor is reduced gait stability. Clinicians do not have sophisticated kinematic options to measure this risk factor with simple and affordable systems. Depth-imaging with AI-pose estimation can be used for gait analysis in young healthy adults. However, is it applicable for measuring gait in older adults at a risk of falling?
METHODS
In this methodological comparison 59 older adults with and without a history of falls walked on a treadmill while their gait pattern was recorded with multiple inertial measurement units and with an Azure Kinect depth-camera. Spatiotemporal gait parameters of both systems were compared for convergent validity and with a Bland-Altman plot.
RESULTS
Correlation between systems for stride length (r=.992, [Formula: see text]) and stride time (r=0.914, [Formula: see text]) was high. Bland-Altman plots revealed a moderate agreement in stride length (-0.74 ± 3.68 cm; [-7.96 cm to 6.47 cm]) and stride time (-3.7±54 ms; [-109 ms to 102 ms]).
CONCLUSION
Gait parameters in older adults with and without a history of falls can be measured with inertial measurement units and Azure Kinect cameras. Affordable and small depth-cameras agree with IMUs for gait analysis in older adults with and without an increased risk of falling. However, tolerable accuracy is limited to the average over multiple steps of spatiotemporal parameters derived from the initial foot contact. Clinical Translation Statement- Gait parameters in older adults with and without a history of falls can be measured with inertial measurement units and Azure Kinect. Affordable and small depth-cameras, developed for various purposes in research and industry, agree with IMUs in clinical gait analysis in older adults with and without an increased risk of falling. However, tolerable accuracy to assess function or monitor changes in gait is limited to the average over multiple steps of spatiotemporal parameters derived from the initial foot contact.

Identifiants

pubmed: 37817821
doi: 10.1109/JTEHM.2023.3277890
pmc: PMC10561749
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

479-486

Informations de copyright

© 2023 The Authors.

Références

IEEE Trans Biomed Eng. 2005 Mar;52(3):486-94
pubmed: 15759579
Gait Posture. 2021 Jun;87:19-26
pubmed: 33878509
Aging Clin Exp Res. 2011 Oct-Dec;23(5-6):393-9
pubmed: 21048423
Sensors (Basel). 2021 Jan 08;21(2):
pubmed: 33430149
Sensors (Basel). 2020 Oct 21;20(20):
pubmed: 33096899
BMC Musculoskelet Disord. 2021 Jun 28;22(1):597
pubmed: 34182955
Gait Posture. 2011 May;34(1):111-8
pubmed: 21531139
Gait Posture. 2008 Apr;27(3):447-54
pubmed: 17616462
Maturitas. 2021 Feb;144:23-28
pubmed: 33358204
PLoS One. 2015 Aug 25;10(8):e0136043
pubmed: 26305896
J Biomech. 2006;39(3):444-52
pubmed: 16389084
Gait Posture. 2015 Feb;41(2):504-9
pubmed: 25582804
Maturitas. 2013 May;75(1):51-61
pubmed: 23523272
Gait Posture. 2007 Jun;26(1):128-34
pubmed: 16982195
J Gerontol A Biol Sci Med Sci. 2009 Aug;64(8):896-901
pubmed: 19349593
Lancet. 1986 Feb 8;1(8476):307-10
pubmed: 2868172
J Gerontol A Biol Sci Med Sci. 2020 May 22;75(6):1148-1153
pubmed: 31428758
Clin Geriatr Med. 2002 May;18(2):141-58
pubmed: 12180240
Gait Posture. 2022 Jul;96:130-136
pubmed: 35635988
IEEE J Transl Eng Health Med. 2020 May 28;8:2100609
pubmed: 32537265
PLoS One. 2019 May 15;14(5):e0215995
pubmed: 31091267
Med Biol Eng Comput. 2018 Dec;56(12):2325-2335
pubmed: 29946955
Geriatr Gerontol Int. 2017 Dec;17(12):2455-2459
pubmed: 28656737
J R Soc Interface. 2013 Mar 20;10(83):20120999
pubmed: 23516062
J Biomech. 2005 Jan;38(1):1-8
pubmed: 15519333
Gait Posture. 2020 Feb;76:136-140
pubmed: 31812791
BMC Geriatr. 2018 Jan 16;18(1):14
pubmed: 29338695
PLoS One. 2018 Apr 19;13(4):e0195902
pubmed: 29672558
J Neuroeng Rehabil. 2014 Sep 11;11:136
pubmed: 25212257
Gait Posture. 2020 Feb;76:110-121
pubmed: 31756666
PLoS One. 2023 Jan 26;18(1):e0279697
pubmed: 36701322
Clin Biomech (Bristol, Avon). 2010 Jun;25(5):444-9
pubmed: 20347194
Sensors (Basel). 2020 Sep 08;20(18):
pubmed: 32911651
Sensors (Basel). 2019 Dec 24;20(1):
pubmed: 31878177
Gait Posture. 2005 Jan;21(1):72-9
pubmed: 15536036
Gait Posture. 2008 May;27(4):710-4
pubmed: 17723303

Auteurs

Michel Hackbarth (M)

School of Medicine and Health ScienceDepartment for Health Services Research, Geriatrics DivisionCarl von Ossietzky University Oldenburg 26129 Oldenburg Germany.

Jessica Koschate (J)

School of Medicine and Health ScienceDepartment for Health Services Research, Geriatrics DivisionCarl von Ossietzky University Oldenburg 26129 Oldenburg Germany.

Sandra Lau (S)

School of Medicine and Health ScienceDepartment for Health Services Research, Geriatrics DivisionCarl von Ossietzky University Oldenburg 26129 Oldenburg Germany.

Tania Zieschang (T)

School of Medicine and Health ScienceDepartment for Health Services Research, Geriatrics DivisionCarl von Ossietzky University Oldenburg 26129 Oldenburg Germany.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH