Hypercarbia and high-flow nasal oxygen use during anaesthesia - risking a failure to thrive?
Airway
anaesthesia
complications
medicine
monitoring
physiology
respiratory
Journal
Anaesthesia and intensive care
ISSN: 0310-057X
Titre abrégé: Anaesth Intensive Care
Pays: United States
ID NLM: 0342017
Informations de publication
Date de publication:
Nov 2023
Nov 2023
Historique:
medline:
30
10
2023
pubmed:
11
10
2023
entrez:
11
10
2023
Statut:
ppublish
Résumé
Prevention of arterial oxygen desaturation during anaesthesia with high-flow nasal oxygen (HFNO) has gained greater acceptance for a widening range of procedures. However, during HFNO use there remains the potential for development of significant anaesthesia-associated apnoea or hypoventilation and the possibility of hypercarbia, with harmful cardiovascular or neurological sequelae. The aim of this study was to determine whether any HFNO-related hypercarbia adverse incidents had been reported on webAIRS, an online database of adverse anaesthesia-related incidents. Two relevant reports were identified of complications due to marked hypercarbia during HFNO use to maintain oxygenation. In both reports, HFNO and total intravenous anaesthesia were used during endoscopic procedures through the upper airway. In both, the extent of hypoventilation went undetected during HFNO use. An ensuing cardiac arrest was reported in one report, ascribed to acute hypercarbia-induced exacerbation of the patient's pre-existing pulmonary hypertension. In the other report, hypercarbia led to a prolonged duration of decreased level of consciousness post procedure, requiring ventilatory support. During the search, an additional 11 reports of postoperative hypercarbia-associated sedation were identified, unrelated to HFNO. In these additional reports an extended duration of severe acute hypercarbia led to sedation or loss of consciousness, consistent with the known effects of hypercarbia on consciousness. These 13 reports highlight the potential dangers of unrecognised and untreated hypercarbia, even if adequate oxygenation is maintained.
Identifiants
pubmed: 37818753
doi: 10.1177/0310057X231198257
doi:
Substances chimiques
Oxygen
S88TT14065
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
400-407Déclaration de conflit d'intérêts
Declaration of conflicting interestsThe authors declared the following potential conflicts of interest with respect to the research, authorship, and/or publication of this article: Yasmin Endlich is the current coordinator of the webAIRS publications group. Martin Culwick is the medical director of the Australian and New Zealand Tripartite Anaesthetic Data Committee. The other authors have no conflicts of interest to declare.