Similarities and discrepancies between commercially available bioelectrical impedance analysis system and dual-energy X-ray absorptiometry for body composition assessment in 10-14-year-old children.


Journal

Scientific reports
ISSN: 2045-2322
Titre abrégé: Sci Rep
Pays: England
ID NLM: 101563288

Informations de publication

Date de publication:
13 10 2023
Historique:
received: 02 02 2023
accepted: 05 10 2023
medline: 23 10 2023
pubmed: 14 10 2023
entrez: 13 10 2023
Statut: epublish

Résumé

A variety of easy-to-use commercial bioelectrical impedance appliances are available. The aim of this study was to examine the usefulness of a commercially available body composition meter using bioelectrical impedance analysis (BIA) by comparing its measurement results with those obtained from dual-energy X-ray absorptiometry (DXA). The participants were 443 children aged from 10 to 14 years (226 boys and 217 girls). Fat mass, fat-free mass, lean body mass, percentage of body fat, and bone mineral contents were evaluated for all participants using BIA and DXA. The agreement in the anthropometric data obtained from both devices was analyzed using correlation analysis, intraclass correlation coefficient (ICC), Lin's concordance correlation coefficient (CCC), Bland-Altman plots, and ordinary least products regression analysis. Equivalence between both devices was tested by two one-sided t-test. All measured indicators showed strong linear correlations between the two measurement systems (r, 0.853-1.000). Fat mass, fat-free mass, and lean body mass showed absolute concordance (ICC, 0.902-0.972; Lin's CCC, 0.902-0.972). BIA overestimated bone mineral content (62.7-66.5%) and underestimated percentage of body fat (- 8.9 to - 0.8%), lean body mass (- 3.5 to - 1.8%), and body mass (- 0.8 to - 0.5%). For fat mass and fat-free mass, the overestimate or underestimate varied according to the sex and statistical analysis test. Bland-Altman analysis and ordinary least products analysis showed fixed bias and proportional bias in all indicators. Results according to quartiles of body mass index showed poor agreement for fat mass and percentage of body fat in both boys and girls in the lowest body mass index quartile. The present results revealed strong linear correlations between BIA and DXA, which confirmed the validity of the present single-frequency BIA-derived parameters. Our results suggest that BIA cannot provide the exact same values as DXA for some body composition parameters, but that performance is sufficient for longitudinal use within an individual for daily health management and monitoring.

Identifiants

pubmed: 37833453
doi: 10.1038/s41598-023-44217-0
pii: 10.1038/s41598-023-44217-0
pmc: PMC10576075
doi:

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

17420

Informations de copyright

© 2023. Springer Nature Limited.

Références

World Health Organization. Obesity and Overweight. https://www.who.int/news-room/fact-sheets/detail/obesity-and-overweight (2022).
Krebs, D. E., Wong, D., Jevsevar, D., Riley, P. O. & Hodge, W. A. Trunk kinematics during locomotor activities. Phys. Ther. 72, 505–514. https://doi.org/10.1093/ptj/72.7.505 (1992).
doi: 10.1093/ptj/72.7.505 pubmed: 1409883
MacKinnon, C. D. & Winter, D. A. Control of whole body balance in the frontal plane during human walking. J. Biomech. 26, 633–644. https://doi.org/10.1016/0021-9290(93)90027-c (1993).
doi: 10.1016/0021-9290(93)90027-c
Cruz-Jentoft, A. J. et al. Sarcopenia: European consensus on definition and diagnosis: Report of the European Working Group on Sarcopenia in Older People. Age Ageing 39, 412–423. https://doi.org/10.1093/ageing/afq034 (2010).
doi: 10.1093/ageing/afq034 pubmed: 20392703 pmcid: 2886201
Rosenberg, I. H. Summary comments. Ame J. Clin. Nutr. 50, 1231–1233. https://doi.org/10.1093/ajcn/50.5.1231 (1989).
doi: 10.1093/ajcn/50.5.1231
Hernandez, C. J., Beaupré, G. S. & Carter, D. R. A theoretical analysis of the relative influences of peak BMD, age-related bone loss and menopause on the development of osteoporosis. Osteoporos. Int. 14, 843–847. https://doi.org/10.1007/s00198-003-1454-8 (2003).
doi: 10.1007/s00198-003-1454-8
Reed, K. E., Warburton, D. E., Macdonald, H. M., Naylor, P. J. & McKay, H. A. Action Schools! BC: A school-based physical activity intervention designed to decrease cardiovascular disease risk factors in children. Prev. Med. 46, 525–531. https://doi.org/10.1016/j.ypmed.2008.02.020 (2008).
doi: 10.1016/j.ypmed.2008.02.020 pubmed: 18377970
Tjønna, A. E. et al. Aerobic interval training reduces cardiovascular risk factors more than a multitreatment approach in overweight adolescents. Clin. Sci. (Lond.) 116, 317–326. https://doi.org/10.1042/cs20080249 (2009).
doi: 10.1042/cs20080249 pubmed: 18673303
Williams, D. P. et al. Body fatness and risk for elevated blood pressure, total cholesterol, and serum lipoprotein ratios in children and adolescents. Am. J. Public Health 82, 358–363. https://doi.org/10.2105/ajph.82.3.358 (1992).
doi: 10.2105/ajph.82.3.358 pubmed: 1536350 pmcid: 1694353
De Lorenzo, A., Martinoli, R., Vaia, F. & Di Renzo, L. Normal weight obese (NWO) women: An evaluation of a candidate new syndrome. Nutr. Metab. Cardiovasc. Dis. 16, 513–523. https://doi.org/10.1016/j.numecd.2005.10.010 (2006).
doi: 10.1016/j.numecd.2005.10.010 pubmed: 17126766
Romero-Corral, A. et al. Normal weight obesity: A risk factor for cardiometabolic dysregulation and cardiovascular mortality. Eur. Heart J. 31, 737–746. https://doi.org/10.1093/eurheartj/ehp487 (2010).
doi: 10.1093/eurheartj/ehp487 pubmed: 19933515
Coutinho, T. et al. Combining body mass index with measures of central obesity in the assessment of mortality in subjects with coronary disease: role of “normal weight central obesity”. J. Am. Coll. Cardiol. 61, 553–560. https://doi.org/10.1016/j.jacc.2012.10.035 (2013).
doi: 10.1016/j.jacc.2012.10.035 pubmed: 23369419
Talma, H. et al. Bioelectrical impedance analysis to estimate body composition in children and adolescents: A systematic review and evidence appraisal of validity, responsiveness, reliability and measurement error. Obes. Rev. 14, 895–905. https://doi.org/10.1111/obr.12061 (2013).
doi: 10.1111/obr.12061 pubmed: 23848977
Fosbøl, M. & Zerahn, B. Contemporary methods of body composition measurement. Clin. Physiol. Funct. Imaging 35, 81–97. https://doi.org/10.1111/cpf.12152 (2015).
doi: 10.1111/cpf.12152 pubmed: 24735332
Genton, L., Hans, D., Kyle, U. G. & Pichard, C. Dual-energy X-ray absorptiometry and body composition: Differences between devices and comparison with reference methods. Nutrition 18, 66–70. https://doi.org/10.1016/s0899-9007(01)00700-6 (2002).
doi: 10.1016/s0899-9007(01)00700-6 pubmed: 11827768
Aandstad, A., Holtberget, K., Hageberg, R., Holme, I. & Anderssen, S. A. Validity and reliability of bioelectrical impedance analysis and skinfold thickness in predicting body fat in military personnel. Mil. Med. 179, 208–217. https://doi.org/10.7205/milmed-d-12-00545 (2014).
doi: 10.7205/milmed-d-12-00545 pubmed: 24491619
Leahy, S., O’Neill, C., Sohun, R. & Jakeman, P. A comparison of dual energy X-ray absorptiometry and bioelectrical impedance analysis to measure total and segmental body composition in healthy young adults. Eur. J. Appl. Physiol. 112, 589–595. https://doi.org/10.1007/s00421-011-2010-4 (2012).
doi: 10.1007/s00421-011-2010-4 pubmed: 21614505
Buckinx, F. et al. Concordance between muscle mass assessed by bioelectrical impedance analysis and by dual energy X-ray absorptiometry: A cross-sectional study. BMC Musculoskelet. Disord. 16, 60. https://doi.org/10.1186/s12891-015-0510-9 (2015).
doi: 10.1186/s12891-015-0510-9 pubmed: 25887598 pmcid: 4369090
McLester, C. N., Nickerson, B. S., Kliszczewicz, B. M. & McLester, J. R. Reliability and agreement of various InBody body composition analyzers as compared to dual-dnergy X-ray absorptiometry in healthy men and women. J. Clin. Densitom. 23, 443–450. https://doi.org/10.1016/j.jocd.2018.10.008 (2020).
doi: 10.1016/j.jocd.2018.10.008 pubmed: 30472111
Raymond, C. J., Dengel, D. R. & Bosch, T. A. Total and segmental body composition examination in collegiate football players using multifrequency bioelectrical impedance analysis and dual X-ray absorptiometry. J. Strength Cond. Res. 32, 772–782. https://doi.org/10.1519/jsc.0000000000002320 (2018).
doi: 10.1519/jsc.0000000000002320 pubmed: 29120982
Moore, M. L., Benavides, M. L., Dellinger, J. R., Adamson, B. T. & Tinsley, G. M. Segmental body composition evaluation by bioelectrical impedance analysis and dual-energy X-ray absorptiometry: Quantifying agreement between methods. Clin. Nutr. 39, 2802–2810. https://doi.org/10.1016/j.clnu.2019.12.009 (2020).
doi: 10.1016/j.clnu.2019.12.009 pubmed: 31874783
Brewer, G. J., Blue, M. N. M., Hirsch, K. R., Peterjohn, A. M. & Smith-Ryan, A. E. Appendicular body composition analysis: Validity of bioelectrical impedance analysis compared with dual-energy X-ray absorptiometry in division I college athletes. J. Strength Cond. Res. 33, 2920–2925. https://doi.org/10.1519/jsc.0000000000003374 (2019).
doi: 10.1519/jsc.0000000000003374 pubmed: 31469766
Ling, C. H. et al. Accuracy of direct segmental multi-frequency bioimpedance analysis in the assessment of total body and segmental body composition in middle-aged adult population. Clin. Nutr. 30, 610–615. https://doi.org/10.1016/j.clnu.2011.04.001 (2011).
doi: 10.1016/j.clnu.2011.04.001 pubmed: 21555168
Kim, M. & Kim, H. Accuracy of segmental multi-frequency bioelectrical impedance analysis for assessing whole-body and appendicular fat mass and lean soft tissue mass in frail women aged 75 years and older. Eur. J. Clin. Nutr. 67, 395–400. https://doi.org/10.1038/ejcn.2013.9 (2013).
doi: 10.1038/ejcn.2013.9 pubmed: 23388666
Li, Y. C. et al. Percentage of body fat assessment using bioelectrical impedance analysis and dual-energy X-ray absorptiometry in a weight loss program for obese or overweight Chinese adults. PLoS One 8, e58272. https://doi.org/10.1371/journal.pone.0058272 (2013).
doi: 10.1371/journal.pone.0058272 pubmed: 23573189 pmcid: 3613423
Esco, M. R. et al. Comparison of total and segmental body composition using DXA and multifrequency bioimpedance in collegiate female athletes. J. Strength Cond. Res. 29, 918–925. https://doi.org/10.1519/jsc.0000000000000732 (2015).
doi: 10.1519/jsc.0000000000000732 pubmed: 25353076
Chula-de-Castro, J. A., Lima, T. R. & Silva, D. A. S. Body composition estimation in children and adolescents by bioelectrical impedance analysis: A systematic review. J. Bodyw. Mov. Ther. 22, 134–146. https://doi.org/10.1016/j.jbmt.2017.04.010 (2018).
doi: 10.1016/j.jbmt.2017.04.010 pubmed: 29332738
Kyle, U. G. et al. Bioelectrical impedance analysis–part I: Review of principles and methods. Clin. Nutr. 23, 1226–1243. https://doi.org/10.1016/j.clnu.2004.06.004 (2004).
doi: 10.1016/j.clnu.2004.06.004 pubmed: 15380917
Gába, A., Kapuš, O., Cuberek, R. & Botek, M. Comparison of multi- and single-frequency bioelectrical impedance analysis with dual-energy X-ray absorptiometry for assessment of body composition in post-menopausal women: effects of body mass index and accelerometer-determined physical activity. J. Hum. Nutr. Diet 28, 390–400. https://doi.org/10.1111/jhn.12257 (2015).
doi: 10.1111/jhn.12257 pubmed: 25039938
Chen, K. T. et al. Comparison of standing posture bioelectrical impedance analysis with DXA for body composition in a large, healthy chinese population. PLoS One 11, e0160105. https://doi.org/10.1371/journal.pone.0160105 (2016).
doi: 10.1371/journal.pone.0160105 pubmed: 27467065 pmcid: 4965215
Parker, H. et al. Accuracy and precision of opportunistic measures of body composition from the Tanita DC-430U. Child Obes. https://doi.org/10.1089/chi.2022.0084 (2022).
doi: 10.1089/chi.2022.0084
Samouda, H. & Langlet, J. Body fat assessment in youth with overweight or obesity by an automated bioelectrical impedance analysis device, in comparison with the dual-energy x-ray absorptiometry: A cross sectional study. BMC Endocr. Disord. 22, 195. https://doi.org/10.1186/s12902-022-01111-6 (2022).
doi: 10.1186/s12902-022-01111-6 pubmed: 35918676 pmcid: 9347159
Holmes, C. J. et al. Comparison of bioelectrical impedance analysis with DXA in adolescents with cystic fibrosis before and after a resistance training intervention. Int. J. Environ. Res. Public Health 19, 896. https://doi.org/10.3390/ijerph19074037 (2022).
doi: 10.3390/ijerph19074037
National Institutes of Health (US). Bioelectrical impedance analysis in body composition measurement: National Institutes of Health Technology Assessment Conference Statement. Ame J. Clin. Nutr. 64, 524S-532S. https://doi.org/10.1093/ajcn/64.3.524S (1996).
doi: 10.1093/ajcn/64.3.524S
Jensky-Squires, N. E. et al. Validity and reliability of body composition analysers in children and adults. Br. J. Nutr. 100, 859–865. https://doi.org/10.1017/s0007114508925460 (2008).
doi: 10.1017/s0007114508925460 pubmed: 18346304
Dixon, P. M. et al. A primer on the use of equivalence testing for evaluating measurement agreement. Med. Sci. Sports Exerc. 50, 837–845. https://doi.org/10.1249/mss.0000000000001481 (2018).
doi: 10.1249/mss.0000000000001481 pubmed: 29135817 pmcid: 5856600
Lakens, D. Equivalence tests: A practical primer for t tests, correlations, and meta-analyses. Soc. Psychol. Personal. Sci. 8, 355–362. https://doi.org/10.1177/1948550617697177 (2017).
doi: 10.1177/1948550617697177 pubmed: 28736600 pmcid: 5502906
Larsen, M. N., Krustrup, P., Araújo Póvoas, S. C. & Castagna, C. Accuracy and reliability of the InBody 270 multi-frequency body composition analyser in 10–12-year-old children. PLoS One 16, e0247362. https://doi.org/10.1371/journal.pone.0247362 (2021).
doi: 10.1371/journal.pone.0247362 pubmed: 33770106 pmcid: 7996997
Weir, J. P. Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. J. Strength Cond. Res. 19, 231–240. https://doi.org/10.1519/15184.1 (2005).
doi: 10.1519/15184.1 pubmed: 15705040
Hopkins, W. G., Marshall, S. W., Batterham, A. M. & Hanin, J. Progressive statistics for studies in sports medicine and exercise science. Med. Sci. Sports Exerc. 41, 3–13. https://doi.org/10.1249/MSS.0b013e31818cb278 (2009).
doi: 10.1249/MSS.0b013e31818cb278 pubmed: 19092709
Shrout, P. E. & Fleiss, J. L. Intraclass correlations: Uses in assessing rater reliability. Psychol. Bull. 86, 420–428. https://doi.org/10.1037//0033-2909.86.2.420 (1979).
doi: 10.1037//0033-2909.86.2.420 pubmed: 18839484
Koo, T. K. & Li, M. Y. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J. Chiropr. Med. 15, 155–163. https://doi.org/10.1016/j.jcm.2016.02.012 (2016).
doi: 10.1016/j.jcm.2016.02.012 pubmed: 27330520 pmcid: 4913118
Lin, L. I. A concordance correlation coefficient to evaluate reproducibility. Biometrics 45, 255–268 (1989).
doi: 10.2307/2532051 pubmed: 2720055
McBride, G. A Proposal for Strength-Of-Agreement Criteria for Lin’s Concordance Correlation Coefficient (National Institute of Water & Atmospheric Research, 2005).
Bland, J. M. & Altman, D. G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1, 307–310 (1986).
doi: 10.1016/S0140-6736(86)90837-8 pubmed: 2868172
Ludbrook, J. Statistical techniques for comparing measurers and methods of measurement: A critical review. Clin. Exp. Pharmacol. Physiol. 29, 527–536. https://doi.org/10.1046/j.1440-1681.2002.03686.x (2002).
doi: 10.1046/j.1440-1681.2002.03686.x pubmed: 12060093
Lake, J. et al. The reliability and validity of the bar-mounted PUSH Band(TM) 2.0 during bench press with moderate and heavy loads. J. Sports Sci. 37, 2685–2690. https://doi.org/10.1080/02640414.2019.1656703 (2019).
doi: 10.1080/02640414.2019.1656703 pubmed: 31418312
Lake, J. P. et al. The validity of the Push Band 2.0 during vertical jump performance. Sports Basel 6, 89. https://doi.org/10.3390/sports6040140 (2018).
doi: 10.3390/sports6040140
Lee, L. W. et al. Validation of two portable bioelectrical impedance analyses for the assessment of body composition in school age children. PLoS One 12, e0171568. https://doi.org/10.1371/journal.pone.0171568 (2017).
doi: 10.1371/journal.pone.0171568 pubmed: 28158304 pmcid: 5291432
Lopez-Gonzalez, D., Wells, J. C. K. & Clark, P. Body composition assessment in mexican children and adolescents. Part 2: Cross-validation of three bio-electrical impedance methods against dual X-ray absorptiometry for total-body and regional body composition. Nutrients 14, 5. https://doi.org/10.3390/nu14050965 (2022).
doi: 10.3390/nu14050965
Seo, Y. G. et al. Validation of body composition using bioelectrical impedance analysis in children according to the degree of obesity. Scand. J. Med. Sci. Sports 28, 2207–2215. https://doi.org/10.1111/sms.13248 (2018).
doi: 10.1111/sms.13248 pubmed: 29938849
Wang, L. & Hui, S. S. Validity of four commercial bioelectrical impedance scales in measuring body fat among chinese children and adolescents. Biomed. Res. Int. 2015, 614858. https://doi.org/10.1155/2015/614858 (2015).
doi: 10.1155/2015/614858 pubmed: 26167491 pmcid: 4475745
Lakens, D., Scheel, A. M. & Isager, P. M. Equivalence testing for psychological research: A tutorial. Adv. Methods Pract. Psychol. Sci. 1, 259–269. https://doi.org/10.1177/2515245918770963 (2018).
doi: 10.1177/2515245918770963
de Castro, J. A. C., de Lima, L. R. A. & Silva, D. A. S. Accuracy of octa-polar bioelectrical impedance analysis for the assessment of total and appendicular body composition in children and adolescents with HIV: Comparison with dual energy X-ray absorptiometry and air displacement plethysmography. J. Hum. Nutr. Diet 31, 276–285. https://doi.org/10.1111/jhn.12501 (2018).
doi: 10.1111/jhn.12501 pubmed: 28799180
Chiplonkar, S. et al. Validation of bioelectric impedance analysis against dual-energy X-ray absorptiometry for assessment of body composition in indian children aged 5 to 18 years. Indian Pediatr. 54, 919–924. https://doi.org/10.1007/s13312-017-1182-3 (2017).
doi: 10.1007/s13312-017-1182-3 pubmed: 28849765
Mazess, R. B., Barden, H. S., Bisek, J. P. & Hanson, J. Dual-energy x-ray absorptiometry for total-body and regional bone-mineral and soft-tissue composition. Am. J. Clin. Nutr. 51, 1106–1112. https://doi.org/10.1093/ajcn/51.6.1106 (1990).
doi: 10.1093/ajcn/51.6.1106 pubmed: 2349926
Ellis, K. J. Human body composition: in vivo methods. Physiol. Rev. 80, 649–680. https://doi.org/10.1152/physrev.2000.80.2.649 (2000).
doi: 10.1152/physrev.2000.80.2.649 pubmed: 10747204
Mattoo, T. K., Lu, H., Ayers, E. & Thomas, R. Total body water by BIA in children and young adults with normal and excessive weight. PLoS One 15, e0239212. https://doi.org/10.1371/journal.pone.0239212 (2020).
doi: 10.1371/journal.pone.0239212 pubmed: 33031479 pmcid: 7544096
Kyle, U. G., Earthman, C. P., Pichard, C. & Coss-Bu, J. A. Body composition during growth in children: Limitations and perspectives of bioelectrical impedance analysis. Eur. J. Clin. Nutr. 69, 1298–1305. https://doi.org/10.1038/ejcn.2015.86 (2015).
doi: 10.1038/ejcn.2015.86 pubmed: 26039314
Andersen, T. B. et al. Precision and within- and between-day variation of bioimpedance parameters in children aged 2–14 years. Clin. Nutr. 30, 326–331. https://doi.org/10.1016/j.clnu.2010.10.005 (2011).
doi: 10.1016/j.clnu.2010.10.005 pubmed: 21074302

Auteurs

Kumiko Ohara (K)

Department of Hygiene and Public Health, Kansai Medical University, 2-5-1 Shin-machi, Hirakata, Osaka, 573-1010, Japan.
Graduate School of Human Development and Environment, Kobe University, 3-11 Tsurukabuto, Nada, Kobe, Hyogo, 657-8501, Japan.

Harunobu Nakamura (H)

Department of Hygiene and Public Health, Kansai Medical University, 2-5-1 Shin-machi, Hirakata, Osaka, 573-1010, Japan. nakamhar@hirakata.kmu.ac.jp.
Graduate School of Human Development and Environment, Kobe University, 3-11 Tsurukabuto, Nada, Kobe, Hyogo, 657-8501, Japan. nakamhar@hirakata.kmu.ac.jp.

Katsuyasu Kouda (K)

Department of Hygiene and Public Health, Kansai Medical University, 2-5-1 Shin-machi, Hirakata, Osaka, 573-1010, Japan.

Yuki Fujita (Y)

Center for Medical Education, Kindai University Faculty of Medicine, 377-2 Oono-Higashi, Osaka-Sayama, Osaka, 589-8511, Japan.

Tomoki Mase (T)

Faculty of Human Development and Education, Kyoto Women's University, 35 Imagumanokitahiyoshi-cho, Higashiyama, Kyoto, Kyoto, 605-8501, Japan.

Katsumasa Momoi (K)

Faculty of Human Development and Education, Kyoto Women's University, 35 Imagumanokitahiyoshi-cho, Higashiyama, Kyoto, Kyoto, 605-8501, Japan.

Toshimasa Nishiyama (T)

Department of Hygiene and Public Health, Kansai Medical University, 2-5-1 Shin-machi, Hirakata, Osaka, 573-1010, Japan.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH