The Role of Improved Motion-Sensitized Driven Equilibrium Blood Suppression and Fat Saturation on T
T2 mapping
black blood technique
double inversion recovery
improved motion-sensitized driven equilibrium
Journal
Journal of magnetic resonance imaging : JMRI
ISSN: 1522-2586
Titre abrégé: J Magn Reson Imaging
Pays: United States
ID NLM: 9105850
Informations de publication
Date de publication:
18 Oct 2023
18 Oct 2023
Historique:
revised:
03
10
2023
received:
31
08
2023
accepted:
03
10
2023
medline:
18
10
2023
pubmed:
18
10
2023
entrez:
18
10
2023
Statut:
aheadofprint
Résumé
T To assess T Prospective. 48 healthy volunteers (46.7 +/- 21.5 years, 24 male) with no cardiac history. GraSE sequence with DIR (GraSE Global T Paired t-tests or non-parametric equivalents for comparisons between sequences. The Bland-Altmann plots and Pearson rank correlation analyses, as appropriate. A P value <0.05 was considered statistically significant. The mean global T All GraSE sequence variants exhibited approximately the same results and variations in the DB technique and addition of FS did not have significant impact on myocardial T 2 TECHNICAL EFFICACY: Stage 1.
Sections du résumé
BACKGROUND
BACKGROUND
T
PURPOSE
OBJECTIVE
To assess T
STUDY TYPE
METHODS
Prospective.
POPULATION
METHODS
48 healthy volunteers (46.7 +/- 21.5 years, 24 male) with no cardiac history.
FIELD STRENGTH/SEQUENCE
UNASSIGNED
GraSE sequence with DIR (GraSE
ASSESSMENT
RESULTS
Global T
STATISTICAL TESTS
METHODS
Paired t-tests or non-parametric equivalents for comparisons between sequences. The Bland-Altmann plots and Pearson rank correlation analyses, as appropriate. A P value <0.05 was considered statistically significant.
RESULTS
RESULTS
The mean global T
DATA CONCLUSION
CONCLUSIONS
All GraSE sequence variants exhibited approximately the same results and variations in the DB technique and addition of FS did not have significant impact on myocardial T
LEVEL OF EVIDENCE
METHODS
2 TECHNICAL EFFICACY: Stage 1.
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
© 2023 International Society for Magnetic Resonance in Medicine.
Références
Gastl M, Gotschy A, von Spiczak J, et al. Cardiovascular magnetic resonance T2* mapping for structural alterations in hypertrophic cardiomyopathy. Eur J Radiol Open 2019;6:78-84.
Thavendiranathan P, Walls M, Giri S, et al. Improved detection of myocardial involvement in acute inflammatory cardiomyopathies using T2 mapping. Circ Cardiovasc Imaging 2012;5:102-110.
Verhaert D, Thavendiranathan P, Giri S, et al. Direct T2 quantification of myocardial edema in acute ischemic injury. JACC Cardiovasc Imaging 2011;4:269-278.
Messroghli DR, Moon JC, Ferreira VM, et al. Clinical recommendations for cardiovascular magnetic resonance mapping of T1, T2, T2* and extracellular volume: A consensus statement by the Society for Cardiovascular Magnetic Resonance (SCMR) endorsed by the European Association for Cardiovascular Imaging (EACVI). J Cardiovasc Magn Reson 2017;19:1-24.
Zhao H, Huang R, Jiang M, et al. Myocardial tissue-level characteristics of adults with metabolically healthy obesity. JACC Cardiovasc Imaging 2023;16:889-901.
O'Brien AT, Gil KE, Varghese J, Simonetti OP, Zareba KM. T2 mapping in myocardial disease: A comprehensive review. J Cardiovasc Magn Reson 2022;24:1-25.
Baeßler B, Schaarschmidt F, Stehning C, Schnackenburg B, Maintz D, Bunck AC. A systematic evaluation of three different cardiac T2-mapping sequences at 1.5 and 3T in healthy volunteers. Eur J Radiol 2015;84:2161-2170.
Yang HJ, Sharif B, Pang J, et al. Free-breathing, motion-corrected, highly efficient whole heart T2 mapping at 3T with hybrid radial-cartesian trajectory. Magn Reson Med 2016;75:126-136.
Baeßler B, Schaarschmidt F, Stehning C, et al. Reproducibility of three different cardiac T2-mapping sequences at 1.5 T. J Magn Reson Imaging 2016;44:1168-1178.
Sprinkart AM, Luetkens JA, Träber F, et al. Gradient spin Echo (GraSE) imaging for fast myocardial T2 mapping. J Cardiovasc Magn Reson 2015;17:1-9.
Mansfield P, Pykett IL. Biological and medical imaging by NMR. J Magn Reson 1978;29:355-373.
He M, Xu J, Sun Z, et al. Comparison and evaluation of the efficacy of compressed SENSE (CS) and gradient-and spin-echo (GRASE) in breath-hold (BH) magnetic resonance cholangiopancreatography (MRCP). J Magn Reson Imaging 2020;51:824-832.
Groarke JD, Waller AH, Vita TS, et al. Feasibility study of electrocardiographic and respiratory gated, gadolinium enhanced magnetic resonance angiography of pulmonary veins and the impact of heart rate and rhythm on study quality. J Cardiovasc Magn Reson 2014;16:1-11.
Henningsson M, Malik S, Botnar R, Castellanos D, Hussain T, Leiner T. Black-blood contrast in cardiovascular MRI. J Magn Reson Imaging 2022;55:61-80.
Kulkarni AA, Ramiah R, Chudgar PD, Burkule NJ. Diverse radiologic presentations of common pathology: Role of cardiac magnetic resonance in the workup of intracardiac thrombi and mimics-a pictorial review. J Indian Acad Echocardiogr Cardiovasc Imaging 2022;6:116-128.
Rodgers CT, Robson MD. Cardiovascular magnetic resonance: Physics and terminology. Prog Cardiovasc Dis 2011;54:181-190.
White JA, Kim HW, Shah D, et al. CMR imaging with rapid visual T1 assessment predicts mortality in patients suspected of cardiac amyloidosis. JACC Cardiovasc Imaging 2014;7:143-156.
Li L, Miller KL, Jezzard P. DANTE-prepared pulse trains: A novel approach to motion-sensitized and motion-suppressed quantitative magnetic resonance imaging. Magn Reson Med 2012;68:1423-1438.
Smulders MW, Bekkers SC, Kim HW, Van Assche LM, Parker MA, Kim RJ. Performance of CMR methods for differentiating acute from chronic MI. J JACC Cardiovasc Imaging 2015;8:669-679.
Wang J, Yarnykh VL, Hatsukami T, Chu B, Balu N, Yuan C. Improved suppression of plaque-mimicking artifacts in black-blood carotid atherosclerosis imaging using a multislice motion-sensitized driven-equilibrium (MSDE) turbo spin-echo (TSE) sequence. Magn Reson Med 2007;58:973-981.
Srinivasan S, Hu P, Kissinger KV, et al. Free-breathing 3D whole-heart black-blood imaging with motion sensitized driven equilibrium. J Magn Reson Imaging 2012;36:379-386.
Zhu C, Graves MJ, Yuan J, Sadat U, Gillard JH, Patterson AJ. Optimization of improved motion-sensitized driven-equilibrium (iMSDE) blood suppression for carotid artery wall imaging. J Cardiovasc Magn Reson 2014;16:1-11.
Jun C, Shuhua L, Xue Z, Chunqing B, Mingli H. Application of motion-sensitized driven equilibrium based black blood 3D TSE sequence in the detection of brain metastases. Magn Reson Imaging 2022;93:145-148.
Bachrata B, Trattnig S, Robinson SD. Quantitative susceptibility mapping of the head-and-neck using SMURF fat-water imaging with chemical shift and relaxation rate corrections. Magn Reson Med 2022;87:1461-1479.
Cerqueira MD, Weissman NJ, Dilsizian V, et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the cardiac imaging Committee of the Council on clinical cardiology of the American Heart Association. Circulation 2002;105:539-542.
Giri S, Chung Y-C, Merchant A, et al. T2 quantification for improved detection of myocardial edema. J Cardiovasc Magn Reson 2009;11:1-13.
Del Grande F, Delcogliano M, Guglielmi R, et al. Fully automated 10-minute 3D CAIPIRINHA SPACE TSE MRI of the knee in adults: A multicenter, multireader, multifield-strength validation study. Invest Radiol 2018;53:689-697.
Milotta G, Ginami G, Cruz G, Neji R, Prieto C, Botnar RM. Simultaneous 3D whole-heart bright-blood and black blood imaging for cardiovascular anatomy and wall assessment with interleaved T2prep-IR. Magn Reson Med 2019;82:312-325.
Hu C, Huber S, Nguyen V, Baldassarre L, Mojibian H, Peters D. Fat-saturated dark-blood cardiac T2 mapping in a single breath-hold. Magn Reson Imaging 2021;81:24-32.
Tessa C, Diciotti S, Landini N, et al. Myocardial T1 and T2 mapping in diastolic and systolic phase. Int J Cardiovasc Imaging 2015;31:1001-1010.
Edelman RR, Chien D, Kim D. Fast selective black blood MR imaging. Radiology 1991;181:655-660.
Wang J, Gerretsen SC, Maki JH, et al. Time-efficient black blood RCA wall imaging at 3T using improved motion sensitized driven equilibrium (iMSDE): Feasibility and reproducibility. PloS One 2011;6:1-10.
Rehwald WG, Jensen CJ, Jenista E, Darty S, Spatz D, Kim RJ. Highly effective fat suppression in clinical T1-weighted imaging of ischemic and non-ischemic heart disease with DeSPAIR. J Cardiovasc Magn Reson 2012;14:1-3.
Kellman P, Hernando D, Shah S, et al. Multiecho Dixon fat and water separation method for detecting fibrofatty infiltration in the myocardium. Magn Reson Med 2009;61:215-221.
von Knobelsdorff-Brenkenhoff F, Prothmann M, Dieringer MA, et al. Myocardial T 1 and T 2 mapping at 3 T: Reference values, influencing factors and implications. J Cardiovasc Magn Reson 2013;15:1-11.
Meloni A, Martini N, Positano V, et al. Myocardial T1 values at 1.5 T: Normal values for General Electric scanners and sex-related differences. J Magn Reson Imaging 2021;54:1486-1500.
Bönner F, Janzarik N, Jacoby C, et al. Myocardial T2 mapping reveals age-and sex-related differences in volunteers. J Cardiovasc Magn Reson 2015;17:1-11.
Meloni A, Nicola M, Positano V, et al. Myocardial T2 values at 1.5 T by a segmental approach with healthy aging and gender. Eur Radiol 2022;32:1-14.
Wang F, Zhou S, Hou B, et al. Assessment of idiopathic inflammatory myopathy using a deep learning method for muscle T2 mapping segmentation. Eur Radiol 2023;33:2350-2357.
Chu M-L, Chien C-P, Wu W-C, Chung H-W. Gradient-and spin-echo (GRASE) MR imaging: A long-existing technology that may find wide applications in modern era. Quant Imaging Med Surg 2019;9:1477-1484.
Zhu C, Graves MJ, Yuan J, Sadat U, Gillard JH, Patterson AJ. Optimization of improved motion-sensitized driven-equilibrium (iMSDE) blood suppression for carotid artery wall imaging. J Cardiovasc Magn Reson 2014;16:1.