Expanded biochemical analyses of human tear fluid: Polyvalent faces of the schirmer strip.
Molecular investigations
Pre-analytical procedures
Sample preparation
Schirmer strip
Tear film
Journal
Experimental eye research
ISSN: 1096-0007
Titre abrégé: Exp Eye Res
Pays: England
ID NLM: 0370707
Informations de publication
Date de publication:
Dec 2023
Dec 2023
Historique:
received:
22
07
2023
revised:
27
09
2023
accepted:
16
10
2023
medline:
27
11
2023
pubmed:
20
10
2023
entrez:
20
10
2023
Statut:
ppublish
Résumé
The tear film forms a protective barrier between the ocular surface and the external environment. Despite its small volume, recent advancements in preanalytical and analytical procedures have enabled its in-depth analysis using multiple approaches. However, the diversity of tear film collection methods and the lack of standardization in pre-analytical methods represent the main obstacles to reproducible results and comparison among different studies. In this study, we first improved the pre-analytical procedures for the extraction of various molecular entities from Schirmer strips (ScS). Subsequently, our investigation focused on analyzing the molecular variances that might occur between two primary tear collection methods: capillary tube (CT) and ScS. Additionally, we examined different parts of the ScS to underscore these variations, which could serve as crucial factors for developing a standardized, optimized protocol for sample processing. Our results show that the inclusion of surfactants in the extraction process enhanced both the yield of protein extraction and the number of proteins identified in ScS, by effectively lysing the cells and improving the solubility of several intracellular proteins. In addition to proteins, nucleic acids could also be recovered for gene expression analyses, particularly from the bulb region of the ScS which is placed in the cul-de-sac. Despite their diluted nature, extracts from ScS remain a suitable material for retrieving tear proteins such as IL-17A at levels as low as the fg/mL range, thanks to highly sensitive immunoassays. Collection methods can affect measured tear protein levels. Lactoferrin is found in higher percentages in capillary electrophoresis analysis of tears collected using ScS compared to tears collected by CT (39.6 ± 4.8% versus 31 ± 4.4%).
Identifiants
pubmed: 37858607
pii: S0014-4835(23)00300-7
doi: 10.1016/j.exer.2023.109679
pii:
doi:
Substances chimiques
Surface-Active Agents
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
109679Informations de copyright
Copyright © 2023 The Authors. Published by Elsevier Ltd.. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest C.B. is a consultant for Aerie, Alcon, Allergan, Horus Pharma, Santen, and Théa; C.B. and F.B.-B. have received research grants from Horus Pharma, Santen, and Théa.