Artificial Intelligence-based Quantification of Pleural Plaque Volume and Association With Lung Function in Asbestos-exposed Patients.
Journal
Journal of thoracic imaging
ISSN: 1536-0237
Titre abrégé: J Thorac Imaging
Pays: United States
ID NLM: 8606160
Informations de publication
Date de publication:
01 May 2024
01 May 2024
Historique:
pubmed:
31
10
2023
medline:
31
10
2023
entrez:
31
10
2023
Statut:
ppublish
Résumé
Pleural plaques (PPs) are morphologic manifestations of long-term asbestos exposure. The relationship between PP and lung function is not well understood, whereas the time-consuming nature of PP delineation to obtain volume impedes research. To automate the laborious task of delineation, we aimed to develop automatic artificial intelligence (AI)-driven segmentation of PP. Moreover, we aimed to explore the relationship between pleural plaque volume (PPV) and pulmonary function tests. Radiologists manually delineated PPs retrospectively in computed tomography (CT) images of patients with occupational exposure to asbestos (May 2014 to November 2019). We trained an AI model with a no-new-UNet architecture. The Dice Similarity Coefficient quantified the overlap between AI and radiologists. The Spearman correlation coefficient ( r ) was used for the correlation between PPV and pulmonary function test metrics. When recorded, these were vital capacity (VC), forced vital capacity (FVC), and diffusing capacity for carbon monoxide (DLCO). We trained the AI system on 422 CT scans in 5 folds, each time with a different fold (n = 84 to 85) as a test set. On these independent test sets combined, the correlation between the predicted volumes and the ground truth was r = 0.90, and the median overlap was 0.71 Dice Similarity Coefficient. We found weak to moderate correlations with PPV for VC (n = 80, r = -0.40) and FVC (n = 82, r = -0.38), but no correlation for DLCO (n = 84, r = -0.09). When the cohort was split on the median PPV, we observed statistically significantly lower VC ( P = 0.001) and FVC ( P = 0.04) values for the higher PPV patients, but not for DLCO ( P = 0.19). We successfully developed an AI algorithm to automatically segment PP in CT images to enable fast volume extraction. Moreover, we have observed that PPV is associated with loss in VC and FVC.
Identifiants
pubmed: 37905941
doi: 10.1097/RTI.0000000000000759
pii: 00005382-990000000-00107
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
165-172Informations de copyright
Copyright © 2023 The Author(s). Published by Wolters Kluwer Health, Inc.
Déclaration de conflit d'intérêts
J.A.B. is on the advisory board of Roche International (payment to institution) and received financial support and free drugs for an investigator-initiated study by MSD. The remaining authors declare no conflict of interest.
Références
Int J Environ Res Public Health. 2022 Jan 27;19(3):
pubmed: 35162440
Inhal Toxicol. 2015 Jan;27(1):15-44
pubmed: 25518994
Eur Respir J. 2017 Jan 3;49(1):
pubmed: 28049168
Inhal Toxicol. 2015;27(7):321-34
pubmed: 26075933
Eur Respir J. 2012 Dec;40(6):1324-43
pubmed: 22743675
Radiographics. 2002 Oct;22 Spec No:S167-84
pubmed: 12376609
Sarcoidosis Vasc Diffuse Lung Dis. 2017;34(4):336-342
pubmed: 32476866
Magn Reson Imaging. 2012 Nov;30(9):1323-41
pubmed: 22770690
Eur Respir Rev. 2018 Jan 24;27(147):
pubmed: 29367408
J Thorac Dis. 2018 Apr;10(4):2118-2124
pubmed: 29850115
J Natl Cancer Inst. 2013 Feb 20;105(4):293-301
pubmed: 23355760
BMC Med Educ. 2023 Mar 23;23(1):181
pubmed: 36959581
Eur Respir J. 2009 Jul;34(1):72-9
pubmed: 19129281
J Thorac Imaging. 2019 Sep;34(5):320-325
pubmed: 30489434
Nat Methods. 2021 Feb;18(2):203-211
pubmed: 33288961
Clin Radiol. 2000 Jun;55(6):422-32
pubmed: 10873686
Annu Rev Pathol. 2013 Jan 24;8:161-87
pubmed: 23347351
Eur Respir Rev. 2020 Oct 28;29(158):
pubmed: 33115787
Respiration. 2008;76(1):1-15
pubmed: 18583923
Occup Environ Med. 2015 Aug;72(8):606-14
pubmed: 25504898
Ned Tijdschr Geneeskd. 2016;160:D544
pubmed: 27781966
Curr Opin Pulm Med. 2012 Jul;18(4):377-81
pubmed: 22617814