Evaluation of torsional strength and torque presentation of coated rectangular stainless steel archwires, an in vitro study.
Bewertung von Torsionsstabilität und Torque-Übertragung von beschichteten rechtwinkligen Edelstahlbögen, eine In-vitro-Studie.
Esthetic coatings
Esthetic orthodontic archwires
Finishing
Fixed orthodontic appliances
Torque application
Journal
Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie
ISSN: 1615-6714
Titre abrégé: J Orofac Orthop
Pays: Germany
ID NLM: 9713484
Informations de publication
Date de publication:
01 Nov 2023
01 Nov 2023
Historique:
received:
05
06
2022
accepted:
11
08
2023
medline:
1
11
2023
pubmed:
1
11
2023
entrez:
1
11
2023
Statut:
aheadofprint
Résumé
An in vitro experimental study was performed to evaluate the torsional strength and torque released by esthetic coated archwires. A total of 52 coated (study group) and 52 stainless steel (control group) rectangular archwires from two manufacturers (brand I: Gestenco International AB, Gothenburg, Sweden and brand II: Ortho Technology, Lutz, FL, USA) in two sizes (0.019 × 0.025 and 0.017 × 0.0250-inch) were evaluated. The straight parts on both ends of each preformed archwire were cut in 30 mm segments. A specially designed experimental device was attached to the universal testing machine (Model Z020, Zwick Roell, Ulm, Germany) to measure torsional strength and to calculate the clinically significant torque interval. The groups were compared based on their brand, presence of coating and size using three-way analysis of variance (ANOVA) test at a significance level of 5%. The results revealed that coating of the wires of brand 1 resulted in a significant reduction of torsional strength in both wire sizes (P-value = 0.0001). For the wires of brand 2, coating of the 0.017 × 0.025-in wire resulted in a significant reduction in torsional strength. However, for the 0.019 × 0.025 in wire size, the presence of coating significantly increased the torsional strength (P-value = 0.0001). Coating did not affect the measured clinical torque interval of the analyzed wires when a torque between 5 and 20 Nmm was applied (P-value = 0.062). Mechanical behavior of coated archwires depends mainly on the thickness of their inner core alloy. Reduction in the diameter of the inner alloy resulted in reduced torsional strength. Despite lower mean torsional strength, in the settings of this study, coated and conventional wires demonstrated comparable torque angles if loaded in the typical range of activation. ZIELSETZUNG: Es wurde eine experimentelle In-vitro-Studie durchgeführt, um Torsionsfestigkeit und freigesetzten Torque von ästhetisch beschichteten Bögen zu bewerten. Insgesamt 52 beschichtete rechtwinklige Bögen (Studiengruppe) und 52 rechtwinklige Bögen aus rostfreiem Stahl (Kontrollgruppe) von 2 Herstellern (I: Marke: Gestenco International AB, Göteborg, Schweden, und II: Ortho Technology, Lutz/FL, USA) in 2 Größen (0,019 × 0,025 und 0,017 × 0,0250 Inch [in]) wurden untersucht. Die geraden Teile an beiden Enden jedes vorgeformten Bogens wurden in 30-mm-Segmente geschnitten. Eine speziell konstruierte experimentelle Vorrichtung wurde an der Universalprüfmaschine (Modell Z020, Zwick Roell, Ulm, Deutschland) angebracht, um die Torsionsfestigkeit zu messen und den klinisch signifikanten Torque-Bereich zu berechnen. Die Gruppen wurden auf der Grundlage der verwendeten Fabrikate, des Vorhandenseins von Beschichtungen und der Größe mittels einer dreifachen Varianzanalyse (ANOVA) auf einem Signifikanzniveau von 5% verglichen. Die Ergebnisse zeigten, dass die Beschichtung der Drähte von Fabrikat I zu einer signifikanten Verringerung der Torsionsfestigkeit in beiden Drahtgrößen führte (p = 0,0001). Bei den Drähten von Fabrikat II führte die Beschichtung des Drahtes 0,017 × 0,025 in zu einer signifikanten Verringerung der Torsionsfestigkeit. Bei den Drähten der Größe 0,019 × 0,025 erhöhte die Beschichtung jedoch die Torsionsfestigkeit signifikant (p = 0,0001). Die Beschichtung hatte keinen Einfluss auf das gemessene klinische Torque-Intervall der untersuchten Drähte, wenn ein Torque zwischen 5 und 20 Nmm aufgebracht wurde (p = 0,062). Das mechanische Verhalten von beschichteten Drähten hängt hauptsächlich von der Dicke der inneren Kernlegierung ab. Eine Verringerung des Durchmessers der inneren Legierung führte zu einer geringeren Torsionsfestigkeit. Trotz der geringeren mittleren Torsionsfestigkeit wiesen beschichtete und konventionelle Drähte in den Einstellungen dieser Studie bei Belastung im typischen Aktivierungsbereich vergleichbare Torque-Winkel auf.
Autres résumés
Type: Publisher
(ger)
ZIELSETZUNG: Es wurde eine experimentelle In-vitro-Studie durchgeführt, um Torsionsfestigkeit und freigesetzten Torque von ästhetisch beschichteten Bögen zu bewerten.
Identifiants
pubmed: 37910176
doi: 10.1007/s00056-023-00503-0
pii: 10.1007/s00056-023-00503-0
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
© 2023. The Author(s), under exclusive licence to Springer Medizin Verlag GmbH, ein Teil von Springer Nature.
Références
Albuquerque CG, Correr AB, Venezian GC, Santamaria M Jr., Tubel CA, Vedovello SA (2017) Deflection and flexural strength effects on the roughness of aesthetic-coated orthodontic wires. Braz Dent J 28(1):40–45. https://doi.org/10.1590/0103-6440201700630
doi: 10.1590/0103-6440201700630
pubmed: 28301016
da Silva DL, Mattos CT, Sant’ Anna EF, Ruellas AC, Elias CN (2013) Cross-section dimensions and mechanical properties of esthetic orthodontic coated archwires. Am J Orthod Dentofacial Orthop 143(4 Suppl):S85–S91. https://doi.org/10.1016/j.ajodo.2012.09.009
doi: 10.1016/j.ajodo.2012.09.009
pubmed: 23540641
Kuo E, Miller RJ (2003) Automated custom-manufacturing technology in orthodontics. Am J Orthod Dentofacial Orthop 123(5):578–581. https://doi.org/10.1016/S0889-5406(03)00051-9
doi: 10.1016/S0889-5406(03)00051-9
pubmed: 12750680
Forsch M, Krull L, Hechtner M, Rahimi R, Wriedt S, Wehrbein H, Jacobs C (2020) Perception of esthetic orthodontic appliances: an eye tracking and cross-sectional study. Angle Orthod 90(1):109–117. https://doi.org/10.2319/031419-198.1
doi: 10.2319/031419-198.1
pubmed: 31403837
Russell JS (2005) Aesthetic orthodontic brackets. J Orthod 32(2):146–163. https://doi.org/10.1179/146531205225021024
doi: 10.1179/146531205225021024
pubmed: 15994990
Muguruma T, Iijima M, Yuasa T, Kawaguchi K, Mizoguchi I (2016) Characterization of the coatings covering esthetic orthodontic archwires and their influence on the bending and frictional properties. Angle Orthod. https://doi.org/10.2319/022416-161.1
doi: 10.2319/022416-161.1
pubmed: 27731649
Iijima M, Muguruma T, Brantley W, Choe HC, Nakagaki S, Alapati SB et al (2012) Effect of coating on properties of esthetic orthodontic nickel-titanium wires. Angle Orthod 82(2):319–325. https://doi.org/10.2319/021511-112.1
doi: 10.2319/021511-112.1
pubmed: 21827235
Kaphoor AA, Sundareswaran S (2012) Aesthetic nickel titanium wires—how much do they deliver? Eur J Orthod 34(5):603–609. https://doi.org/10.1093/ejo/cjr089
doi: 10.1093/ejo/cjr089
pubmed: 21791711
Ryu SH, Lim BS, Kwak EJ, Lee GJ, Choi S, Park KH (2015) Surface ultrastructure and mechanical properties of three different white-coated NiTi archwires. Scanning 37(6):414–421
doi: 10.1002/sca.21230
pubmed: 26130130
Choi S, Park DJ, Kim KA, Park KH, Park HK, Park YG (2015) In vitro sliding-driven morphological changes in representative esthetic NiTi archwire surfaces. Microsc Res Tech 78(10):926–934. https://doi.org/10.1002/jemt.22557
doi: 10.1002/jemt.22557
pubmed: 26278620
Ramadan AA (2003) Removing hepatitis C virus from polytetrafluoroethylene-coated orthodontic archwires and other dental instruments. East Mediterr Health J 9(3):274–278
doi: 10.26719/2003.9.3.274
pubmed: 15751919
Husmann P, Bourauel C, Wessinger M, Jager A (2002) The frictional behavior of coated guiding archwires. J Orofac Orthop 63(3):199–211. https://doi.org/10.1007/s00056-002-0009-5
doi: 10.1007/s00056-002-0009-5
pubmed: 12132308
Kim IH, Park HS, Kim YK, Kim KH, Kwon TY (2014) Comparative short-term in vitro analysis of mutans streptococci adhesion on esthetic, nickel-titanium, and stainless-steel arch wires. Angle Orthod 84(4):680–686. https://doi.org/10.2319/061713-456.1
doi: 10.2319/061713-456.1
pubmed: 24308530
Elayyan F, Silikas N, Bearn D (2010) Mechanical properties of coated superelastic archwires in conventional and self-ligating orthodontic brackets. Am J Orthod Dentofacial Orthop 137(2):213–217. https://doi.org/10.1016/j.ajodo.2008.01.026
doi: 10.1016/j.ajodo.2008.01.026
pubmed: 20152677
Badawi HM, Toogood RW, Carey JP, Heo G, Major PW (2008) Torque expression of self-ligating brackets. Am J Orthod Dentofacial Orthop 133(5):721–728. https://doi.org/10.1016/j.ajodo.2006.01.051
doi: 10.1016/j.ajodo.2006.01.051
pubmed: 18456146
Gioka C, Eliades T (2004) Materials-induced variation in the torque expression of preadjusted appliances. Am J Orthod Dentofacial Orthop 125(3):323–328. https://doi.org/10.1016/j.ajodo.2003.02.007
doi: 10.1016/j.ajodo.2003.02.007
pubmed: 15014409
Meling TR, Odegaard J, Meling EO (1997) On mechanical properties of square and rectangular stainless steel wires tested in torsion. Am J Orthod Dentofacial Orthop 111(3):310–320. https://doi.org/10.1016/S0889-5406(97)70190-2
doi: 10.1016/S0889-5406(97)70190-2
pubmed: 9082854
Sebanc J, Brantley WA, Pincsak JJ, Conover JP (1984) Variability of effective root torque as a function of edge bevel on orthodontic arch wires. Am J Orthod Dentofacial Orthop 86(1):43–51. https://doi.org/10.1016/0002-9416(84)90275-6
doi: 10.1016/0002-9416(84)90275-6
McKnight MM, Jones SP, Davies EH (1994) A study to compare the effects of simulated torquing forces on pre-adjusted orthodontic brackets. Br J Orthod 21(4):359–365. https://doi.org/10.1179/bjo.21.4.359
doi: 10.1179/bjo.21.4.359
pubmed: 7857895
Ajami S, Boroujeni AR (2018) Impact of different rectangular wires on torsional expression of different sizes of buccal tube. J Clin Exp Dent 10(1):e25–e31. https://doi.org/10.4317/jced.54300
doi: 10.4317/jced.54300
pubmed: 29670712
pmcid: 5899803
Burstone CJ (1982) The segmented arch approach to space closure. Am J Orthod 82(5):361–378. https://doi.org/10.1016/0002-9416(82)90185-3
doi: 10.1016/0002-9416(82)90185-3
pubmed: 6961808