Disturbance in bodily experience following ventricular assist device implantation.

VAD body image disturbance in bodily experience psychological device integration ventricular assist device

Journal

The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation
ISSN: 1557-3117
Titre abrégé: J Heart Lung Transplant
Pays: United States
ID NLM: 9102703

Informations de publication

Date de publication:
03 Nov 2023
Historique:
received: 17 03 2023
revised: 23 09 2023
accepted: 26 10 2023
pubmed: 6 11 2023
medline: 6 11 2023
entrez: 3 11 2023
Statut: aheadofprint

Résumé

Disturbance in bodily experience (BE) is a potential adverse consequence of ventricular assist device (VAD) implantation. The concept BE encompasses all cognitive and affective processes related to the subjective experience of one's own body. A cross-sectional, multicenter study was performed, involving 365 VAD patients (85% male; time postimplant: 3-36 months). Patients completed a BE questionnaire (BE-S, 5-point Likert scale), and the disturbance in BE was analyzed based on sex, time since implantation (in the first, second, or third years postimplant), and patient acuity (elective vs emergent implantation). Subsidiary, patients' gratitude was surveyed. Disturbance in BE was not particularly pronounced (mean = 2.69, standard deviation = 1.17). Eighty-five percent of patients expressed high levels of gratitude. Disturbance in BE decreased (p = 0.04), while gratitude increased (p = 0.02) with time since implantation. Female patients showed more disturbance in BE (p = 0.01) and less gratitude (p = 0.01) compared to male patients. Among patients who underwent emergency implantation, the decrease in disturbance occurred predominantly in the third year, exceeding the level observed in elective implanted patients (p = 0.03). Disturbance in BE following VAD implantation does generally not reach excessive levels and tends to decrease over time. Our data indicate more disturbance and less gratitude in female patients. In emergently implanted patients, disturbance in BE is prolonged. Screening for disturbance in BE is recommended during follow-up, especially for these at-risk groups, to ensure early and focused psychological support.

Sections du résumé

BACKGROUND BACKGROUND
Disturbance in bodily experience (BE) is a potential adverse consequence of ventricular assist device (VAD) implantation. The concept BE encompasses all cognitive and affective processes related to the subjective experience of one's own body.
METHODS METHODS
A cross-sectional, multicenter study was performed, involving 365 VAD patients (85% male; time postimplant: 3-36 months). Patients completed a BE questionnaire (BE-S, 5-point Likert scale), and the disturbance in BE was analyzed based on sex, time since implantation (in the first, second, or third years postimplant), and patient acuity (elective vs emergent implantation). Subsidiary, patients' gratitude was surveyed.
RESULTS RESULTS
Disturbance in BE was not particularly pronounced (mean = 2.69, standard deviation = 1.17). Eighty-five percent of patients expressed high levels of gratitude. Disturbance in BE decreased (p = 0.04), while gratitude increased (p = 0.02) with time since implantation. Female patients showed more disturbance in BE (p = 0.01) and less gratitude (p = 0.01) compared to male patients. Among patients who underwent emergency implantation, the decrease in disturbance occurred predominantly in the third year, exceeding the level observed in elective implanted patients (p = 0.03).
CONCLUSIONS CONCLUSIONS
Disturbance in BE following VAD implantation does generally not reach excessive levels and tends to decrease over time. Our data indicate more disturbance and less gratitude in female patients. In emergently implanted patients, disturbance in BE is prolonged. Screening for disturbance in BE is recommended during follow-up, especially for these at-risk groups, to ensure early and focused psychological support.

Identifiants

pubmed: 37923150
pii: S1053-2498(23)02109-5
doi: 10.1016/j.healun.2023.10.019
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Informations de copyright

Copyright © 2023 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

Auteurs

Fabian Richter (F)

Deutsches Herzzentrum der Charité, Department of Cardiothoracic and Vascular Surgery, Berlin, Germany; Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.

Hannah Spielmann (H)

University of Freiburg, Faculty of Medicine, Institute of Nursing Science, Freiburg, Germany.

Sandra Semmig-Koenze (S)

Leipzig Heart Center, Leipzig, Germany.

Christine Spitz-Köberich (C)

Medical Center - University of Freiburg, University Heart Center Freiburg, Bad Krozingen, Germany.

Christoph Knosalla (C)

Deutsches Herzzentrum der Charité, Department of Cardiothoracic and Vascular Surgery, Berlin, Germany; Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany; DZHK (German Centre for Cardiovascular Research), partner site Berlin, Berlin, Germany.

Christiane Kugler (C)

University of Freiburg, Faculty of Medicine, Institute of Nursing Science, Freiburg, Germany.

Katharina Tigges-Limmer (K)

Heart and Diabetes Center North-Rhine Westphalia, University Hospital of the Ruhr University Bochum, Bad Oeynhausen, Germany.

Wolfgang Albert (W)

Deutsches Herzzentrum der Charité, Department of Cardiothoracic and Vascular Surgery, Berlin, Germany; Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany; DZHK (German Centre for Cardiovascular Research), partner site Berlin, Berlin, Germany. Electronic address: wolfgang.albert@dhzc-charite.de.

Classifications MeSH