A comparison of ultrafast and conventional spectral Doppler ultrasound to measure cerebral blood flow velocity during inguinal hernia repair in infants.


Journal

Journal of clinical anesthesia
ISSN: 1873-4529
Titre abrégé: J Clin Anesth
Pays: United States
ID NLM: 8812166

Informations de publication

Date de publication:
02 2024
Historique:
received: 29 07 2023
revised: 13 10 2023
accepted: 28 10 2023
medline: 24 11 2023
pubmed: 6 11 2023
entrez: 5 11 2023
Statut: ppublish

Résumé

Ultrafast cerebral Doppler ultrasound enables simultaneous quantification and visualization of cerebral blood flow velocity. The aim of this study is to compare the use of conventional and ultrafast spectral Doppler during anesthesia and their potential to show the effect of anesthesiologic procedures on cerebral blood flow velocities, in relation to blood pressure and cerebral oxygenation in infants undergoing inguinal hernia repair. A single-center prospective observational cohort study in infants up to six months of age. We evaluated conventional and ultrafast spectral Doppler cerebral ultrasound measurements in terms of number of successful measurements during the induction of anesthesia, after sevoflurane induction, administration of caudal analgesia, a fluid bolus and emergence of anesthesia. Cerebral blood flow velocity was quantified in pial arteries using conventional spectral Doppler and in the cerebral cortex using ultrafast Doppler by peak systolic velocity, end diastolic velocity and resistivity index. Twenty infants were included with useable conventional spectral Doppler images in 72/100 measurements and ultrafast Doppler images in 51/100 measurements. Intraoperatively, the success rates were 53/60 (88.3%) and 41/60 (68.3%), respectively. Cerebral blood flow velocity increased after emergence for both conventional (end diastolic velocity, from 2.01 to 2.75 cm/s, p < 0.001) and ultrafast spectral Doppler (end diastolic velocity, from 0.59 to 0.94 cm/s), whereas cerebral oxygenation showed a reverse pattern with a decrease after the emergence of the infant (85% to 68%, p < 0.001). It is possible to quantify cortical blood flow velocity during general anesthesia using conventional and ultrafast spectral Doppler cerebral ultrasound. Cerebral blood flow velocity and blood pressure decreased, while regional cerebral oxygenation increased during general anesthesia. Ultrafast spectral Doppler ultrasound offers novel insights into perfusion within the cerebral cortex, unattainable through conventional spectral ultrasound. Yet, ultrafast Doppler is curtailed by a lower success rate and a more rigorous learning curve compared to conventional method.

Sections du résumé

BACKGROUND
Ultrafast cerebral Doppler ultrasound enables simultaneous quantification and visualization of cerebral blood flow velocity. The aim of this study is to compare the use of conventional and ultrafast spectral Doppler during anesthesia and their potential to show the effect of anesthesiologic procedures on cerebral blood flow velocities, in relation to blood pressure and cerebral oxygenation in infants undergoing inguinal hernia repair.
METHODS
A single-center prospective observational cohort study in infants up to six months of age. We evaluated conventional and ultrafast spectral Doppler cerebral ultrasound measurements in terms of number of successful measurements during the induction of anesthesia, after sevoflurane induction, administration of caudal analgesia, a fluid bolus and emergence of anesthesia. Cerebral blood flow velocity was quantified in pial arteries using conventional spectral Doppler and in the cerebral cortex using ultrafast Doppler by peak systolic velocity, end diastolic velocity and resistivity index.
RESULTS
Twenty infants were included with useable conventional spectral Doppler images in 72/100 measurements and ultrafast Doppler images in 51/100 measurements. Intraoperatively, the success rates were 53/60 (88.3%) and 41/60 (68.3%), respectively. Cerebral blood flow velocity increased after emergence for both conventional (end diastolic velocity, from 2.01 to 2.75 cm/s, p < 0.001) and ultrafast spectral Doppler (end diastolic velocity, from 0.59 to 0.94 cm/s), whereas cerebral oxygenation showed a reverse pattern with a decrease after the emergence of the infant (85% to 68%, p < 0.001).
CONCLUSION
It is possible to quantify cortical blood flow velocity during general anesthesia using conventional and ultrafast spectral Doppler cerebral ultrasound. Cerebral blood flow velocity and blood pressure decreased, while regional cerebral oxygenation increased during general anesthesia. Ultrafast spectral Doppler ultrasound offers novel insights into perfusion within the cerebral cortex, unattainable through conventional spectral ultrasound. Yet, ultrafast Doppler is curtailed by a lower success rate and a more rigorous learning curve compared to conventional method.

Identifiants

pubmed: 37926064
pii: S0952-8180(23)00262-3
doi: 10.1016/j.jclinane.2023.111312
pii:
doi:

Types de publication

Observational Study Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

111312

Informations de copyright

Copyright © 2023. Published by Elsevier Inc.

Déclaration de conflit d'intérêts

Declaration of Competing Interest The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.

Auteurs

Mathies Rondagh (M)

Department of Anesthesiology, Erasmus MC University Medical Centre Rotterdam, Rotterdam, the Netherlands.

Anna J Kortenbout (AJ)

Department of Biomedical Engineering, Erasmus MC University Medical Centre Rotterdam, Rotterdam, the Netherlands.

Sophie de Munck (S)

Department of Surgery, Erasmus MC University Medical Centre Rotterdam, Rotterdam, the Netherlands.

Gerbrich E van den Bosch (GE)

Department of Neonatology, Erasmus MC University Medical Centre Rotterdam, Rotterdam, the Netherlands.

Jeroen Dudink (J)

Department of Neonatology, UMC Utrecht University Medical Centre Utrecht, Utrecht, the Netherlands.

Hendrik J Vos (HJ)

Department of Biomedical Engineering, Erasmus MC University Medical Centre Rotterdam, Rotterdam, the Netherlands.

Johan G Bosch (JG)

Department of Biomedical Engineering, Erasmus MC University Medical Centre Rotterdam, Rotterdam, the Netherlands.

Jurgen C de Graaff (JC)

Department of Anesthesiology, Erasmus MC University Medical Centre Rotterdam, Rotterdam, the Netherlands; Department of Anesthesiology, Adrz - Erasmus MC, Goes, the Netherlands; Department of Anesthesiology, Weill Cornell Medicine, New York, NY, United States of America. Electronic address: j.degraaff@erasmusmc.nl.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH