Biomimetic Stents for Infra-inguinal Peripheral Arterial Disease: Systematic Review and Meta-Analysis.

Biomimetic Chronic limb threatening ischaemia Limb salvage Peripheral arterial disease Stent

Journal

European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery
ISSN: 1532-2165
Titre abrégé: Eur J Vasc Endovasc Surg
Pays: England
ID NLM: 9512728

Informations de publication

Date de publication:
04 Nov 2023
Historique:
received: 02 06 2023
revised: 30 09 2023
accepted: 03 11 2023
medline: 7 11 2023
pubmed: 7 11 2023
entrez: 6 11 2023
Statut: aheadofprint

Résumé

Biomimetic stents are peripheral infra-inguinal self-expanding stents that mimic the anatomy of the vasculature and artery movement. They are indicated for use in infra-inguinal arteries. This research aimed to synthesise all current evidence on the use of biomimetic stents as adjuncts for endovascular treatment of infra-inguinal peripheral arterial disease (PAD), helping to guide clinical decision making. MEDLINE, Embase, CINAHL and Cochrane databases. Random effects meta-analysis following PRISMA guidelines (PROSPERO registration CRD42022385256). Study quality was assessed using the Joanna Briggs Institute critical appraisal tools checklist, and certainty assessment through the Grading of Recommendations, Assessment, Development and Evaluation (GRADE). Endpoints included primary patency, target lesion revascularisation, stent fracture, secondary patency, and mortality at 1 year. In total, 37 studies were included in the meta-analysis (33 cohort studies, 2 case series, and 2 randomised controlled trials [RCTs]), representing 4 480 participants. Of these, 34 studies included data on Supera (81.5% of participants) and 3 studies reported data on BioMimics 3D (18.5% of participants) stents. The pooled primary patency rate of 33 studies at 1 year follow up was 81.4% (95% confidence interval [CI] 78.7 - 83.9%), and the pooled target lesion revascularisation rate of 18 studies at 1 year was 12.2% (95% CI 9.6 - 15.0%). The certainty of evidence outcome rating as qualified by GRADE was very low for both. Only one study reported a positive stent fracture rate at 1 year follow up of 0.4% with a certainty of evidence outcome of low. Using biomimetic stents for infra-inguinal PAD may be associated with acceptable 1 year primary patency and target lesion revascularisation rates, with near negligible 1 year stent fracture rate. Their use should be considered in those presenting with infra-inguinal PAD undergoing endovascular revascularisation. A RCT trial is necessary to determine their clinical and cost effectiveness.

Identifiants

pubmed: 37931680
pii: S1078-5884(23)00894-8
doi: 10.1016/j.ejvs.2023.11.007
pii:
doi:

Types de publication

Journal Article Review

Langues

eng

Sous-ensembles de citation

IM

Informations de copyright

Copyright © 2023 The Author(s). Published by Elsevier B.V. All rights reserved.

Auteurs

Sarah Jane Messeder (SJ)

Department of Cardiovascular Sciences, University of Leicester, NIHR Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK; Leicester Vascular Institute, University Hospitals of Leicester, Glenfield Hospital, Leicester, UK; British Heart Foundation, Clinical Research Training Fellow, Leicester, UK. Electronic address: sjm104@leicester.ac.uk.

Gabriel López-Peña (G)

Leicester Vascular Institute, University Hospitals of Leicester, Glenfield Hospital, Leicester, UK.

Coral Pepper (C)

Library and Information Services, University Hospitals of Leicester NHS Trust, Leicester Royal Infirmary, Leicester, UK.

Athanasios Saratzis (A)

Department of Cardiovascular Sciences, University of Leicester, NIHR Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK; Leicester Vascular Institute, University Hospitals of Leicester, Glenfield Hospital, Leicester, UK.

Classifications MeSH