Mechanical evaluation of revision surgery for femoral shaft nonunion initially treated with intramedullary nailing: Exchange nailing versus augmentation plating.
Augmentation plating
Callus
Exchange nailing
Femoral shaft nonunion
Instability
Intramedullary nailing
Quantitative CT-based finite element analysis
Revision surgery
Journal
Injury
ISSN: 1879-0267
Titre abrégé: Injury
Pays: Netherlands
ID NLM: 0226040
Informations de publication
Date de publication:
Dec 2023
Dec 2023
Historique:
received:
07
08
2023
revised:
11
10
2023
accepted:
23
10
2023
medline:
5
12
2023
pubmed:
9
11
2023
entrez:
8
11
2023
Statut:
ppublish
Résumé
Exchange nailing (EN) or augmentation plating (AP) has been employed to treat nonunions after intramedullary nailing for femoral shaft fractures. Although instability is a factor in hypertrophic nonunion, mechanical evaluations have been limited because the contribution of the callus to fracture site stability varies with healing. Our previous study illustrated the potential for evaluation using a finite element analysis (FEA) that incorporates callus material properties. This study aimed to mechanically evaluate revision surgery for nonunions using FEA. A quantitative computed tomography-based FEA was performed on virtual revision models of a patient with suspected nonunion after intramedullary nailing. In addition to the initial nailing model (IN) with an 11-mm diameter (D) and 360-mm length (L), four EN models with D12mm (EN1), D13mm (EN2), D12mm-L400mm (EN3), and D13mm-L400mm (EN4) nails and three AP models with 5- (AP1), 6- (AP2), and 7-hole (AP3) plates were created. As with bone, callus was assigned inhomogeneous material properties derived from density based on an empirical formula. The hip joint reaction force and muscle forces at maximum load during the gait cycle were applied. The volume ratio of the callus at the fracture site with a tensile failure risk of ≥1 (tensile failure ratio) and bone fragment movement were evaluated. The tensile failure ratio was 11.6 % (IN), 10.1 % (EN1), 6.3 % (EN2), 10.9 % (EN3), 6.2 % (EN4), 6.4 % (AP1), 7.2 % (AP2), and 7.7 % (AP3), respectively. The bone fragment movement showed an opening on the lateral side with the initial intramedullary nailing. However, both revision surgeries reduced the opening, leading to compression except in the EN1 model. The proximal bone fragments were internally rotated relative to the distal fragments, and the rotational instability was more suppressed in models with lower tensile failure ratio. For EN, the increase in diameter, not length, is important to suppress instability. AP reduces instability, comparable to a 2 mm increase in nail diameter, and screw fixation closer to the fracture site reduces instability. This study suggest that AP is mechanically equivalent to EN and could be an option for revision surgery for femoral shaft nonunions.
Identifiants
pubmed: 37939634
pii: S0020-1383(23)00880-X
doi: 10.1016/j.injury.2023.111163
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
111163Informations de copyright
Copyright © 2023 Elsevier Ltd. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of Competing Interest There are no conflicts of interest to declare.