Additive Prognostic Value of Left Ventricular Dispersion and Deformation in Patients With Severe Aortic Stenosis.

aortic stenosis mechanical dispersion outcome speckle tracking

Journal

JACC. Cardiovascular imaging
ISSN: 1876-7591
Titre abrégé: JACC Cardiovasc Imaging
Pays: United States
ID NLM: 101467978

Informations de publication

Date de publication:
28 Oct 2023
Historique:
received: 14 04 2023
revised: 12 09 2023
accepted: 25 09 2023
medline: 9 11 2023
pubmed: 9 11 2023
entrez: 9 11 2023
Statut: aheadofprint

Résumé

Speckle tracking strain echocardiography allows one to visualize the timing of maximum regional strain and quantifies left ventricular-mechanical dispersion (LV-MD). Whether LV-MD and LV-global longitudinal strain (LV-GLS) provide similar or complementary information in mortality risk stratification in patients with severe aortic stenosis (SAS) remains unknown. We hypothesized that LV mechanical dyssynchrony assessed by LV-MD is associated with an increased risk of mortality and provides additional prognostic information on top of LV-GLS in patients with SAS. A total of 364 patients with SAS (aortic valve area indexed ≤0.6 cm During a median follow-up period of 41 months, 149 patients died. After adjustment, LV-MD ≥68 ms was significantly associated with an increased risk of mortality (adjusted HR: 1.41; 95% CI: 1.01-1.96; P = 0.044). Adding LV-MD ≥68 ms to a multivariable Cox regression model including LV-GLS ≥-15% improved predictive performance in terms of overall mortality, with improved global model fit, reclassification, and better discrimination. Patients with both criteria had an important increase in mortality compared to patients with none or one criterion (adjusted HR: 2.02; 95% CI: 1.34-3.03; P = 0.001). Interobserver reproducibility of LV-MD was good with an intraclass correlation coefficient of 0.90 (95% CI: 0.72-0.97). LV-MD is a reproducible parameter independently associated with an increased risk of mortality in SAS. Increased LV-MD associated with depressed LV-GLS identifies a subgroup of patients with an increased mortality risk. Whether early aortic valve replacement improves the outcome of these patients deserves further studies.

Sections du résumé

BACKGROUND BACKGROUND
Speckle tracking strain echocardiography allows one to visualize the timing of maximum regional strain and quantifies left ventricular-mechanical dispersion (LV-MD). Whether LV-MD and LV-global longitudinal strain (LV-GLS) provide similar or complementary information in mortality risk stratification in patients with severe aortic stenosis (SAS) remains unknown.
OBJECTIVES OBJECTIVE
We hypothesized that LV mechanical dyssynchrony assessed by LV-MD is associated with an increased risk of mortality and provides additional prognostic information on top of LV-GLS in patients with SAS.
METHODS METHODS
A total of 364 patients with SAS (aortic valve area indexed ≤0.6 cm
RESULTS RESULTS
During a median follow-up period of 41 months, 149 patients died. After adjustment, LV-MD ≥68 ms was significantly associated with an increased risk of mortality (adjusted HR: 1.41; 95% CI: 1.01-1.96; P = 0.044). Adding LV-MD ≥68 ms to a multivariable Cox regression model including LV-GLS ≥-15% improved predictive performance in terms of overall mortality, with improved global model fit, reclassification, and better discrimination. Patients with both criteria had an important increase in mortality compared to patients with none or one criterion (adjusted HR: 2.02; 95% CI: 1.34-3.03; P = 0.001). Interobserver reproducibility of LV-MD was good with an intraclass correlation coefficient of 0.90 (95% CI: 0.72-0.97).
CONCLUSIONS CONCLUSIONS
LV-MD is a reproducible parameter independently associated with an increased risk of mortality in SAS. Increased LV-MD associated with depressed LV-GLS identifies a subgroup of patients with an increased mortality risk. Whether early aortic valve replacement improves the outcome of these patients deserves further studies.

Identifiants

pubmed: 37943232
pii: S1936-878X(23)00436-9
doi: 10.1016/j.jcmg.2023.09.010
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Informations de copyright

Copyright © 2023 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Déclaration de conflit d'intérêts

Funding Support and Author Disclosures The authors have reported that they have no relationships relevant to the contents of this paper to disclose.

Auteurs

Nicolas Thellier (N)

Lille Catholic Hospitals, Heart Valve Center, Cardiology Department, ETHICS EA 7446, Lille Catholic University, Lille, France.

Alexandre Altes (A)

Lille Catholic Hospitals, Heart Valve Center, Cardiology Department, ETHICS EA 7446, Lille Catholic University, Lille, France.

Michael Rietz (M)

Lille Catholic Hospitals, Heart Valve Center, Cardiology Department, ETHICS EA 7446, Lille Catholic University, Lille, France.

Aymeric Menet (A)

Lille Catholic Hospitals, Heart Valve Center, Cardiology Department, ETHICS EA 7446, Lille Catholic University, Lille, France.

Jeremy Layec (J)

Lille Catholic Hospitals, Heart Valve Center, Cardiology Department, ETHICS EA 7446, Lille Catholic University, Lille, France.

François Outteryck (F)

Lille Catholic Hospitals, Heart Valve Center, Cardiology Department, ETHICS EA 7446, Lille Catholic University, Lille, France.

Ludovic Appert (L)

Lille Catholic Hospitals, Heart Valve Center, Cardiology Department, ETHICS EA 7446, Lille Catholic University, Lille, France.

Christophe Tribouilloy (C)

Amiens University Hospital Center, Amiens, France; EA 7517 MP3CV Jules Verne University of Picardie, Amiens, France.

Sylvestre Maréchaux (S)

Lille Catholic Hospitals, Heart Valve Center, Cardiology Department, ETHICS EA 7446, Lille Catholic University, Lille, France. Electronic address: Marechaux.Sylvestre@ghicl.net.

Classifications MeSH