[Biomechanics of thoracic wall instability].

Biomechanik der Thoraxwandinstabilität.
Breathing mechanics Flail chest Movement Serial rib fracture Sternal fracture

Journal

Unfallchirurgie (Heidelberg, Germany)
ISSN: 2731-703X
Titre abrégé: Unfallchirurgie (Heidelb)
Pays: Germany
ID NLM: 9918384886306676

Informations de publication

Date de publication:
14 Nov 2023
Historique:
accepted: 16 10 2023
medline: 15 11 2023
pubmed: 15 11 2023
entrez: 14 11 2023
Statut: aheadofprint

Résumé

Traumatic injuries of the thorax can entail thoracic wall instability (flail chest), which can affect both the shape of the thorax and the mechanics of respiration; however, so far little is known about the biomechanics of the unstable thoracic wall and the optimal surgical fixation. This review article summarizes the current state of research regarding experimental models and previous findings. The thoracic wall is primarily burdened by complex muscle and compression forces during respiration and the mechanical coupling to spinal movement. Previous experimental models focused on the burden caused by respiration, but are mostly not validated, barely established, and severely limited with respect to the simulation of physiologically occurring forces. Nevertheless, previous results suggested that osteosynthesis of an unstable thoracic wall is essential from a biomechanical point of view to restore the native respiratory mechanics, thoracic shape and spinal stability. Moreover, in vitro studies also showed better stabilizing properties of plate osteosynthesis compared to intramedullary splints, wires or screws. The optimum number and selection of ribs to be fixated for the different types of thoracic wall instability is still unknown from a biomechanical perspective. Future biomechanical investigations should simulate respiratory and spinal movement by means of validated models. Traumatische Thoraxverletzungen können eine Instabilität der Thoraxwand nach sich ziehen, die sowohl die Thoraxkontur als auch die Atemmechanik beeinträchtigen kann. Über die Biomechanik und die optimale chirurgische Fixierung der instabilen Thoraxwand ist bisher jedoch wenig bekannt. Dieser Übersichtsartikel fasst den Stand der Forschung hinsichtlich experimenteller Modelle und bisheriger Erkenntnisse zusammen. Die Thoraxwand wird v. a. durch komplexe Muskel- und Druckkräfte während der Atmung sowie ihre mechanische Kopplung an die Wirbelsäulenbewegung belastet. Bisherige experimentelle Modelle fokussieren sich auf die Belastungen während des Atemvorgangs, sind jedoch zumeist nicht validiert, kaum etabliert und hinsichtlich der Simulation physiologisch auftretender Kräfte stark limitiert. Dennoch deuten bisherige Ergebnisse darauf hin, dass eine Osteosynthese der instabilen Thoraxwand aus biomechanischer Sicht unerlässlich ist, um die native Atemmechanik, Brustkorbkontur und Wirbelsäulenstabilität wiederherzustellen. In-vitro-Studien konnten zudem zeigen, dass eine winkelstabile Plattenosteosynthese bessere stabilisierende Eigenschaften besitzt als intramedulläre Splints, Drähte oder Schrauben. Die optimale Anzahl und die Auswahl der zu fixierenden Rippen für die unterschiedlichen Arten der Thoraxwandinstabilität ist aus biomechanischer Sicht weiterhin unbekannt. Künftige biomechanische Untersuchungen sollten sowohl die Atem- als auch die Wirbelsäulenbewegung mithilfe validierter Modelle simulieren.

Autres résumés

Type: Publisher (ger)
Traumatische Thoraxverletzungen können eine Instabilität der Thoraxwand nach sich ziehen, die sowohl die Thoraxkontur als auch die Atemmechanik beeinträchtigen kann. Über die Biomechanik und die optimale chirurgische Fixierung der instabilen Thoraxwand ist bisher jedoch wenig bekannt. Dieser Übersichtsartikel fasst den Stand der Forschung hinsichtlich experimenteller Modelle und bisheriger Erkenntnisse zusammen. Die Thoraxwand wird v. a. durch komplexe Muskel- und Druckkräfte während der Atmung sowie ihre mechanische Kopplung an die Wirbelsäulenbewegung belastet. Bisherige experimentelle Modelle fokussieren sich auf die Belastungen während des Atemvorgangs, sind jedoch zumeist nicht validiert, kaum etabliert und hinsichtlich der Simulation physiologisch auftretender Kräfte stark limitiert. Dennoch deuten bisherige Ergebnisse darauf hin, dass eine Osteosynthese der instabilen Thoraxwand aus biomechanischer Sicht unerlässlich ist, um die native Atemmechanik, Brustkorbkontur und Wirbelsäulenstabilität wiederherzustellen. In-vitro-Studien konnten zudem zeigen, dass eine winkelstabile Plattenosteosynthese bessere stabilisierende Eigenschaften besitzt als intramedulläre Splints, Drähte oder Schrauben. Die optimale Anzahl und die Auswahl der zu fixierenden Rippen für die unterschiedlichen Arten der Thoraxwandinstabilität ist aus biomechanischer Sicht weiterhin unbekannt. Künftige biomechanische Untersuchungen sollten sowohl die Atem- als auch die Wirbelsäulenbewegung mithilfe validierter Modelle simulieren.

Identifiants

pubmed: 37964040
doi: 10.1007/s00113-023-01389-8
pii: 10.1007/s00113-023-01389-8
doi:

Types de publication

English Abstract Journal Article Review

Langues

ger

Sous-ensembles de citation

IM

Informations de copyright

© 2023. The Author(s), under exclusive licence to Springer Medizin Verlag GmbH, ein Teil von Springer Nature.

Références

Beyer B, Feipel V, Sholukha V et al (2017) In-vivo analysis of sternal angle, sternal and sternocostal kinematics in supine humans during breathing. J Biomech 64:32–40
doi: 10.1016/j.jbiomech.2017.08.026 pubmed: 28916398
Beyer B, Sholukha V, Dugailly PM et al (2014) In vivo thorax 3D modelling from costovertebral joint complex kinematics. Clin Biomech 29(4):434–438
doi: 10.1016/j.clinbiomech.2014.01.007
Beyer B, Van Sint Jan S, Cheze L et al (2016) Relationship between costovertebral joint kinematics and lung volume in supine humans. Respir Physiol Neurobiol 232:57–65
doi: 10.1016/j.resp.2016.07.003 pubmed: 27421681
Bottlang M, Walleser S, Noll M et al (2010) Biomechanical rationale and evaluation of an implant system for rib fracture fixation. Eur J Trauma Emerg Surg 36(5):417–426
doi: 10.1007/s00068-010-0047-4 pubmed: 21841953 pmcid: 3150823
Campbell N, Richardson M, Antippa P (2010) Biomechanical testing of two devices for internal fixation of fractured ribs. J Trauma 68(5):1234–1238
pubmed: 20093978
Cappello M, De Troyer A (2002) On the respiratory function of the ribs. J Appl Physiol 92(4):1642–1646
doi: 10.1152/japplphysiol.01053.2001 pubmed: 11896032
Cappello M, Legrand A, De Troyer A (1999) Determinants of rib motion in flail chest. Am J Respir Crit Care Med 159(3):886–891
doi: 10.1164/ajrccm.159.3.9807089 pubmed: 10051267
De Troyer A, Boriek AM (2011) Mechanics of the respiratory muscles. Compr Physiol 1(3):1273–1300
doi: 10.1002/cphy.c100009 pubmed: 23733642
De Troyer A, Kirkwood PA, Wilson TA (2005) Respiratory action of the intercostal muscles. Physiol Rev 85(2):717–756
doi: 10.1152/physrev.00007.2004 pubmed: 15788709
De Troyer AD, Wilson TA (2016) Action of the diaphragm on the rib cage. J Appl Physiol 121(2):391–400
doi: 10.1152/japplphysiol.00268.2016
Grupp S, Furst V, Buder T et al (2017) Comparative studies of different types of osteosynthesis on the human corpse preparation in bilateral antero-lateral flail chest. Injury 48(12):2709–2716
doi: 10.1016/j.injury.2017.10.015 pubmed: 29037517
Liebsch C, Graf N, Appelt K et al (2017) The rib cage stabilizes the human thoracic spine: An in vitro study using stepwise reduction of rib cage structures. PLoS ONE 12(6):e178733
doi: 10.1371/journal.pone.0178733 pubmed: 28570671 pmcid: 5453693
Liebsch C, Graf N, Wilke H‑J (2017) EUROSPINE 2016 FULL PAPER AWARD: wire cerclage can restore the stability of the thoracic spine after median sternotomy: an in vitro study with entire rib cage specimens. Eur Spine J 26(5):1401–1407
doi: 10.1007/s00586-016-4768-x pubmed: 27639711
Liebsch C, Graf N, Wilke H‑J (2019) In vitro analysis of kinematics and elastostatics of the human rib cage during thoracic spinal movement for the validation of numerical models. J Biomech 94:147–157
doi: 10.1016/j.jbiomech.2019.07.041 pubmed: 31420155
Liebsch C, Hubner S, Palanca M et al (2021) Experimental study exploring the factors that promote rib fragility in the elderly. Sci Rep 11(1):9307
doi: 10.1038/s41598-021-88800-9 pubmed: 33927313 pmcid: 8085244
Liebsch C, Seiffert T, Vlcek M et al (2019) Patterns of serial rib fractures after blunt chest trauma: an analysis of 380 cases. PLoS ONE 14(12):e224105
doi: 10.1371/journal.pone.0224105 pubmed: 31856165 pmcid: 6922429
Liebsch C, Wilke H‑J (2018) Basic biomechanics of the thoracic spine and rib cage. In: Galbusera F, Wilke H‑J (Hrsg) Biomechanics of the spine. Academic Press, London, S 35–50
Liebsch C, Wilke H‑J (2020) Rib presence, anterior rib cage integrity, and segmental length affect the stability of the human thoracic spine: an in vitro study. Front Bioeng Biotechnol 8:46
doi: 10.3389/fbioe.2020.00046 pubmed: 32117927 pmcid: 7018667
Liebsch C, Wilke H‑J (2022) How does the rib cage affect the biomechanical properties of the thoracic spine? A systematic literature review. Front Bioeng Biotechnol 10:904539
doi: 10.3389/fbioe.2022.904539 pubmed: 35782518 pmcid: 9240654
Myers DM, McGowan SP, Taylor BC et al (2020) A model for evaluating the biomechanics of rib fracture fixation. Clin Biomech 80:105191
doi: 10.1016/j.clinbiomech.2020.105191
Ockelmann M, Terbrüggen D (1979) Indikation und Möglichkeiten zur operativen Stabilisierung von Rippen-Reihen-Frakturen bei instabilem Thorax. Prax Klin Pneumol 33:408–413
pubmed: 461319
Sales JR, Ellis TJ, Gillard J et al (2008) Biomechanical testing of a novel, minimally invasive rib fracture plating system. J Trauma 64(5):1270–1274
pubmed: 18469649
Shih KS, Truong TA, Hsu CC et al (2019) Biomechanical investigation of different surgical strategies for the treatment of rib fractures using a three-dimensional human respiratory model. Biomed Tech 64(1):93–102
Slobogean GP, Kim H, Russell JP et al (2015) Rib fracture fixation restores inspiratory volume and peak flow in a full thorax human cadaveric breathing model. Arch Trauma Res 4(4):e28018
doi: 10.5812/atr.28018 pubmed: 26848471 pmcid: 4733518
Spering C, von Hammerstein-Equord A, Lehmann W et al (2021) Osteosyntheseverfahren bei Thoraxwandinstabilität. Oper Orthop Traumatol 33(3):262–284
doi: 10.1007/s00064-020-00688-2 pubmed: 33289872
Thomas CN, Lindquist TJ, Schroder LK et al (2023) Rib fracture map in high-energy injuries. J Orthop Trauma 37(4):e165–e169
doi: 10.1097/BOT.0000000000002531 pubmed: 36730005
Vergari C, Skalli W, Clavel L et al (2022) Functional analysis of the human rib cage over the vital capacity range in standing position using biplanar X‑ray imaging. Comput Biol Med 144:105343
doi: 10.1016/j.compbiomed.2022.105343 pubmed: 35235874
Wilson TA, Legrand A, Gevenois PA et al (2001) Respiratory effects of the external and internal intercostal muscles in humans. J Physiol 530(2):319–330
doi: 10.1111/j.1469-7793.2001.0319l.x pubmed: 11208979 pmcid: 2278403
Wilson TA, Rehder K, Krayer S et al (1987) Geometry and respiratory displacement of human ribs. J Appl Physiol 62(5):1872–1877
doi: 10.1152/jappl.1987.62.5.1872 pubmed: 3597261
Zhang G, Chen X, Ohgi J et al (2018) Effect of intercostal muscle contraction on rib motion in humans studied by finite element analysis. J Appl Physiol 125(4):1165–1170
doi: 10.1152/japplphysiol.00995.2017 pubmed: 30048203

Auteurs

Christian Liebsch (C)

Institut für Unfallchirurgische Forschung und Biomechanik, Zentrum für Traumaforschung Ulm, Universitätsklinikum Ulm, Helmholtzstr. 14, 89081, Ulm, Deutschland. christian.liebsch@uni-ulm.de.

Christopher Spering (C)

Klinik für Unfallchirurgie, Orthopädie und Plastische Chirurgie, Universitätsmedizin Göttingen, Göttingen, Deutschland.

Hans-Joachim Wilke (HJ)

Institut für Unfallchirurgische Forschung und Biomechanik, Zentrum für Traumaforschung Ulm, Universitätsklinikum Ulm, Helmholtzstr. 14, 89081, Ulm, Deutschland.

Classifications MeSH