Tourniquet-free minimally invasive total knee arthroplasty is associated with early aseptic loosening.
Aseptic loosening
Minimally invasive surgery
TKA
Total knee arthroplasty
Tourniquet
Journal
The Knee
ISSN: 1873-5800
Titre abrégé: Knee
Pays: Netherlands
ID NLM: 9430798
Informations de publication
Date de publication:
21 Nov 2023
21 Nov 2023
Historique:
received:
25
06
2023
revised:
08
10
2023
accepted:
07
11
2023
medline:
23
11
2023
pubmed:
23
11
2023
entrez:
22
11
2023
Statut:
aheadofprint
Résumé
While tourniquet-free (T-) total knee arthroplasty (TKA) has gained popularity, tourniquet-use during minimally-invasive (MIS)-TKA has not been adequately studied. Traditional techniques employ knee hyper-flexion, compressing vasculature and reducing impact of bleeding, while MIS-TKA embraces the semi-extended knee position, which does not restrict the effects of bleeding on cementation and visualization. We compared the risk of aseptic loosening between patients undergoing T- MIS-TKA compared to T + MIS-TKA. This single-surgeon cohort study included 329 consecutive MIS-TKA (226 T+,103 T-) patients with minimum 3-year follow-up. Aseptic loosening, radiolucent lines (RLL), health related quality of life scores, and complications were recorded. T-test and chi-square test were used to compare continuous and categorical variables, and logistic regression included BMI, age, ASA, patellar-resurfacing, and tourniquet-use. There were no differences in baseline demographics. One (0.4 %) aseptic loosening occurred with T+, versus 7 (6.8 %) with T- (p = 0.002). No T + and 3 T- patients (2.9 %, p = 0.01) had revision for aseptic loosening. The incidence of RLLs was 16.8 % in T + and 30.1 % in T- (p = 0.008). Logistic regression revealed T + was significantly associated with decreased aseptic loosening and risk of RLL (odds ratio = 16.4, odds ratio = 2.8). In this consecutive series, T- MIS-TKA was associated with increased rates of revision for aseptic loosening as compared to the T + MIS-TKA, even controlling for BMI, age, ASA level, and patellar resurfacing. Radiolucent lines were increased with T- MIS-TKA compared to T + MIS-TKA. Complications, all-cause revision, ROM, and HRQoL scores were similar between tourniquet-use and tourniquet-free cohorts.
Sections du résumé
BACKGROUND
BACKGROUND
While tourniquet-free (T-) total knee arthroplasty (TKA) has gained popularity, tourniquet-use during minimally-invasive (MIS)-TKA has not been adequately studied. Traditional techniques employ knee hyper-flexion, compressing vasculature and reducing impact of bleeding, while MIS-TKA embraces the semi-extended knee position, which does not restrict the effects of bleeding on cementation and visualization. We compared the risk of aseptic loosening between patients undergoing T- MIS-TKA compared to T + MIS-TKA.
METHODS
METHODS
This single-surgeon cohort study included 329 consecutive MIS-TKA (226 T+,103 T-) patients with minimum 3-year follow-up. Aseptic loosening, radiolucent lines (RLL), health related quality of life scores, and complications were recorded. T-test and chi-square test were used to compare continuous and categorical variables, and logistic regression included BMI, age, ASA, patellar-resurfacing, and tourniquet-use.
RESULTS
RESULTS
There were no differences in baseline demographics. One (0.4 %) aseptic loosening occurred with T+, versus 7 (6.8 %) with T- (p = 0.002). No T + and 3 T- patients (2.9 %, p = 0.01) had revision for aseptic loosening. The incidence of RLLs was 16.8 % in T + and 30.1 % in T- (p = 0.008). Logistic regression revealed T + was significantly associated with decreased aseptic loosening and risk of RLL (odds ratio = 16.4, odds ratio = 2.8).
CONCLUSION
CONCLUSIONS
In this consecutive series, T- MIS-TKA was associated with increased rates of revision for aseptic loosening as compared to the T + MIS-TKA, even controlling for BMI, age, ASA level, and patellar resurfacing. Radiolucent lines were increased with T- MIS-TKA compared to T + MIS-TKA. Complications, all-cause revision, ROM, and HRQoL scores were similar between tourniquet-use and tourniquet-free cohorts.
Identifiants
pubmed: 37992467
pii: S0968-0160(23)00230-2
doi: 10.1016/j.knee.2023.11.001
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
19-26Informations de copyright
Copyright © 2023 Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.