Projection Micro-Stereolithography to Manufacture a Biocompatible Micro-Optofluidic Device for Cell Concentration Monitoring.
3D printing
cell concentration detection
micro-optics
microfluidics
photocurable biocompatible resins
two-phase flow detection
vat photopolymerization
Journal
Polymers
ISSN: 2073-4360
Titre abrégé: Polymers (Basel)
Pays: Switzerland
ID NLM: 101545357
Informations de publication
Date de publication:
19 Nov 2023
19 Nov 2023
Historique:
received:
14
10
2023
revised:
15
11
2023
accepted:
16
11
2023
medline:
25
11
2023
pubmed:
25
11
2023
entrez:
25
11
2023
Statut:
epublish
Résumé
In this work, a 3D printed biocompatible micro-optofluidic (MoF) device for two-phase flow monitoring is presented. Both an air-water bi-phase flow and a two-phase mixture composed of micrometric cells suspended on a liquid solution were successfully controlled and monitored through its use. To manufacture the MoF device, a highly innovative microprecision 3D printing technique was used named Projection Microstereolithography (PμSL) in combination with the use of a novel 3D printable photocurable resin suitable for biological and biomedical applications. The concentration monitoring of biological fluids relies on the absorption phenomenon. More precisely, the nature of the transmission of the light strictly depends on the cell concentration: the higher the cell concentration, the lower the optical acquired signal. To achieve this, the microfluidic T-junction device was designed with two micrometric slots for the optical fibers' insertion, needed to acquire the light signal. In fact, both the micro-optical and the microfluidic components were integrated within the developed device. To assess the suitability of the selected biocompatible transparent resin for optical detection relying on the selected working principle (absorption phenomenon), a comparison between a two-phase flow process detected inside a previously fully characterized micro-optofluidic device made of a nonbiocompatible high-performance resin (HTL resin) and the same made of the biocompatible one (BIO resin) was carried out. In this way, it was possible to highlight the main differences between the two different resin grades, which were further justified with proper chemical analysis of the used resins and their hydrophilic/hydrophobic nature via static water contact angle measurements. A wide experimental campaign was performed for the biocompatible device manufactured through the PμSL technique in different operative conditions, i.e., different concentrations of eukaryotic yeast cells of
Identifiants
pubmed: 38006185
pii: polym15224461
doi: 10.3390/polym15224461
pmc: PMC10675802
pii:
doi:
Types de publication
Journal Article
Langues
eng
Subventions
Organisme : European Union (NextGeneration EU)
ID : MUR-PNRR project SAMOTHRACE (CUP: E63C22000900006
Organisme : University of Catania
ID : grant scheme PIACERI with the project MAF-mof "Materiali multifunzionali per dispositivi micro-optofluidici"
Références
Lab Chip. 2011 Jan 7;11(1):104-14
pubmed: 21060932
Anal Methods. 2016 Aug 21;8(31):6005-6012
pubmed: 27617038
Lab Chip. 2016 Feb 21;16(4):668-78
pubmed: 26725379
Cold Spring Harb Protoc. 2011 Sep 01;2011(9):
pubmed: 21880825
Biosens Bioelectron. 2019 Oct 15;143:111597
pubmed: 31442755
Front Bioeng Biotechnol. 2019 Jun 18;7:147
pubmed: 31275933
IEEE Sens J. 2019;19(18):7822-7828
pubmed: 33223968
Rev Med Virol. 2021 Jan;31(1):1-11
pubmed: 32844526
BMC Pulm Med. 2023 Sep 14;23(1):348
pubmed: 37710221
Lab Chip. 2016 Apr 26;16(9):1593-604
pubmed: 27025278
Biosensors (Basel). 2023 Mar 30;13(4):
pubmed: 37185514
Biomicrofluidics. 2023 Jan 23;17(1):014105
pubmed: 36714795
Biomed Microdevices. 2020 May 18;22(2):37
pubmed: 32419044
Front Bioeng Biotechnol. 2020 Sep 08;8:557111
pubmed: 33015017
Anal Bioanal Chem. 2017 Jul;409(18):4311-4319
pubmed: 28612085
Nat Commun. 2020 Oct 19;11(1):5271
pubmed: 33077832
Science. 1993 Aug 13;261(5123):895-7
pubmed: 17783736
Biosens Bioelectron. 2023 Dec 1;241:115579
pubmed: 37690355
Environ Sci Technol. 2015 Dec 15;49(24):14570-8
pubmed: 26506399
Chem Rev. 2017 Aug 9;117(15):10212-10290
pubmed: 28756658
Langmuir. 2009 Sep 15;25(18):10768-81
pubmed: 19591481
Small. 2022 May;18(18):e2106392
pubmed: 35362226
Anal Chim Acta. 2021 May 8;1158:338348
pubmed: 33863415
Polymers (Basel). 2023 Jun 15;15(12):
pubmed: 37376336
Proc Natl Acad Sci U S A. 2020 May 19;117(20):10639-10644
pubmed: 32350139
Biosens Bioelectron. 2019 Sep 15;141:111435
pubmed: 31238280
Lab Chip. 2016 Jul 7;16(13):2376-96
pubmed: 27272540
Biosens Bioelectron. 2023 Jun 15;230:115283
pubmed: 37019031
Biosens Bioelectron. 2023 Feb 15;222:114942
pubmed: 36493722
Polymers (Basel). 2021 Jul 30;13(15):
pubmed: 34372121
Anal Chem. 2019 May 21;91(10):6910-6917
pubmed: 31035747
Electrophoresis. 2021 Jan;42(1-2):86-94
pubmed: 32391575
Lab Chip. 2020 May 19;20(10):1845-1855
pubmed: 32338260
Adv Mater. 2021 Jun;33(25):e2008712
pubmed: 33969565
ACS Appl Bio Mater. 2020 Nov 16;3(11):7550-7561
pubmed: 35019496
Lab Chip. 2019 Apr 9;19(8):1458-1470
pubmed: 30888358
Biosens Bioelectron. 2022 Mar 15;200:113910
pubmed: 34974260
Nanomaterials (Basel). 2021 Oct 06;11(10):
pubmed: 34685065
Anal Chem. 2017 Apr 4;89(7):3858-3866
pubmed: 28281349
Annu Rev Anal Chem (Palo Alto Calif). 2012;5:413-40
pubmed: 22524226
Biotechnol Bioeng. 2005 Jan 5;89(1):1-8
pubmed: 15580587
Materials (Basel). 2016 Sep 07;9(9):
pubmed: 28773881
J Orthop Translat. 2022 Feb 03;33:13-23
pubmed: 35198379
Lab Chip. 2020 Aug 7;20(15):2674-2688
pubmed: 32608464
Lab Chip. 2017 Aug 22;17(17):2899-2909
pubmed: 28726927
Sci Justice. 2006 Jul-Sep;46(3):179-84
pubmed: 17388245
Sensors (Basel). 2014 Aug 21;14(8):15458-79
pubmed: 25196161
J Nanobiotechnology. 2023 Mar 29;21(1):115
pubmed: 36978078