Comparison of the Bruker Microflex LT and Zybio EXS2600 MALDI TOF MS systems for the identification of clinical microorganisms.

Clinical isolates Identification MALDI Mass spectrometry Microorganisms Urinary bacteria

Journal

Diagnostic microbiology and infectious disease
ISSN: 1879-0070
Titre abrégé: Diagn Microbiol Infect Dis
Pays: United States
ID NLM: 8305899

Informations de publication

Date de publication:
25 Nov 2023
Historique:
received: 20 06 2023
revised: 16 11 2023
accepted: 24 11 2023
medline: 1 12 2023
pubmed: 1 12 2023
entrez: 30 11 2023
Statut: aheadofprint

Résumé

The emergence of Matrix-Assisted Laser Desorption/Ionization Time-Of-Flight Mass Spectrometry (MALDI TOF MS) technology has expanded the capabilities for identifying microorganisms in clinical labs, replacing traditional biochemical testing with a proteomic approach. In the present study, we compared results between the two commercial MALDI TOF MS systems, Bruker Microflex LT Biotyper and Zybio EXS2600 Ex-Accuspec, for the identification of 1979 urinary isolates by direct extraction method. Current study found that both systems identified a high percentage of isolates to at least the genus level - Bruker 95.6 % of isolates, Zybio 92.4 %. In the case of 89.5 % of all analyzed spectra, the identification results were consistent between the used devices. The highest score values and the highest percentage of spectra identified to species were obtained for gram-negative bacteria. The results show that both systems are equally good choices in terms of analytical performance for routine microbiological diagnostic procedures.

Identifiants

pubmed: 38035652
pii: S0732-8893(23)00259-6
doi: 10.1016/j.diagmicrobio.2023.116150
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

116150

Informations de copyright

Copyright © 2023. Published by Elsevier Inc.

Déclaration de conflit d'intérêts

Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Auteurs

Ewelina Sibińska (E)

Centre for Modern Interdisciplinary Technologies, Nicolaus Copernicus University in Toruń, Wileńska 4 Str., Toruń 87-100, Poland.

Adrian Arendowski (A)

Centre for Modern Interdisciplinary Technologies, Nicolaus Copernicus University in Toruń, Wileńska 4 Str., Toruń 87-100, Poland. Electronic address: adrian@arendowski.hub.pl.

Piotr Fijałkowski (P)

Centre for Modern Interdisciplinary Technologies, Nicolaus Copernicus University in Toruń, Wileńska 4 Str., Toruń 87-100, Poland.

Dorota Gabryś (D)

Radiotherapy Department, Maria Sklodowska-Curie National Research Institute of Oncology, Wybrzeże Armii Krajowej 15 Str., Gliwice 44-102, Poland.

Paweł Pomastowski (P)

Centre for Modern Interdisciplinary Technologies, Nicolaus Copernicus University in Toruń, Wileńska 4 Str., Toruń 87-100, Poland.

Classifications MeSH