A comparative study of multi and single post labeling delay pseudocontinuous arterial spin labeling in patients with carotid artery stenosis.
Arterial spin labeling
Carotid artery stenosis
Cerebral blood flow
Perfusion
Journal
Magnetic resonance imaging
ISSN: 1873-5894
Titre abrégé: Magn Reson Imaging
Pays: Netherlands
ID NLM: 8214883
Informations de publication
Date de publication:
01 Dec 2023
01 Dec 2023
Historique:
received:
30
06
2023
revised:
06
11
2023
accepted:
20
11
2023
pubmed:
3
12
2023
medline:
3
12
2023
entrez:
2
12
2023
Statut:
aheadofprint
Résumé
Arterial Spin Labeling (ASL) allows for the non-invasive visualization of brain perfusion to detect abnormalities. In unilateral carotid artery stenosis, one hemisphere is less supplied with blood which results in a lower cerebral blood flow (CBF) compared to the healthy side. ASL can be performed time-resolved using multiple post labeling delay (PLD) times after labeling or static with a single delay, the latter allowing for a faster and more robust acquisition while bearing the risk of a falsely set delay resulting in unusable images. The purpose of this study is to compare the performance of multi-PLD and single-PLD ASL in patients with unilateral carotid artery stenosis both as means of diagnosis and therapeutic follow-up examination. ASL perfusion data of 17 patients with known unilateral carotid artery stenosis was used to compare the diagnostic performance of the multi-PLD and single-PLD approach. Comparisons were made based on the CBF values and the added benefit of arrival time maps showing slower blood flow in multi-PLD ASL which might be overlooked in the individual delay images both before and after therapy. Both the multi-PLD and the single-PLD data could identify the side of the stenosis with hemispheric differences in each approach (p < 0.001) and depict the normalization of CBF after therapy (p > 0.05). There were no differences between the individual methods (p > 0.05). In this work, we could show that multi-PLD ASL in patients with unilateral carotid artery stenosis is beneficial as it provides both CBF and arrival time maps, however when only a single-PLD acquisition is available, this appears sufficient in a clinical setting to investigate the presence of a unilateral stenosis.
Identifiants
pubmed: 38042453
pii: S0730-725X(23)00197-2
doi: 10.1016/j.mri.2023.11.011
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
18-23Informations de copyright
Copyright © 2023 Elsevier Inc. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of Competing Interest The authors state that they have no conflicts of interest regarding this manuscript.