Green Solvent-Based Antifouling Polymer Brushes Demonstrate Excellent Hemocompatibility.


Journal

Langmuir : the ACS journal of surfaces and colloids
ISSN: 1520-5827
Titre abrégé: Langmuir
Pays: United States
ID NLM: 9882736

Informations de publication

Date de publication:
04 Dec 2023
Historique:
medline: 4 12 2023
pubmed: 4 12 2023
entrez: 4 12 2023
Statut: aheadofprint

Résumé

Medical devices are crucial for patient care, yet even the best biomaterials lead to infections and unwanted activation of blood coagulation, potentially being life-threatening. While hydrophilic polymer brushes are the best coatings to mitigate these issues, their reliance on fossil raw materials underscores the urgency of bio-based alternatives. In this work, we introduce polymer brushes of a green solvent-based monomer, prohibiting protein adsorption, bacterial colonization, and blood clot formation at the same level as fossil-based polymer brushes. The polymer brushes are composed of

Identifiants

pubmed: 38048267
doi: 10.1021/acs.langmuir.3c02765
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Auteurs

Jenny Englert (J)

DWI─Leibniz Institute for Interactive Materials, Forckenbeckstraße 50, 52074 Aachen, Germany.
Chair of Biotechnology, RWTH Aachen University, 52074 Aachen, Germany.

Marc Palà (M)

Laboratory of Sustainable Polymers, Department of Analytical Chemistry and Organic Chemistry, University Rovira i Virgili, C/Marcel·lí Domingo 1, 43007 Tarragona, Spain.

Lena Witzdam (L)

DWI─Leibniz Institute for Interactive Materials, Forckenbeckstraße 50, 52074 Aachen, Germany.
Institute of Technical and Macromolecular Chemistry, RWTH Aachen University, Worringerweg 2, 52074 Aachen, Germany.
Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), Carrer de Baldiri Reixac 10-12, 08028 Barcelona, Spain.

Farahnaz Rayatdoost (F)

Department of Anesthesiology, RWTH Aachen University Hospital, 52074 Aachen, Germany.

Oliver Grottke (O)

Department of Anesthesiology, RWTH Aachen University Hospital, 52074 Aachen, Germany.

Gerard Lligadas (G)

Laboratory of Sustainable Polymers, Department of Analytical Chemistry and Organic Chemistry, University Rovira i Virgili, C/Marcel·lí Domingo 1, 43007 Tarragona, Spain.

Cesar Rodriguez-Emmenegger (C)

DWI─Leibniz Institute for Interactive Materials, Forckenbeckstraße 50, 52074 Aachen, Germany.
Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), Carrer de Baldiri Reixac 10-12, 08028 Barcelona, Spain.
Institució Catalana de Recerca i Estudis Avançats (ICREA), Passeig Lluís Companys 23, 08010 Barcelona, Spain.
Biomedical Research Networking, Center in Bioengineering, Biomaterials and Nanomedicine, The Institute of Health Carlos III, 28029 Madrid, Spain.

Classifications MeSH