Analytical interference of intravascular contrast agents with clinical laboratory tests: a joint guideline by the ESUR Contrast Media Safety Committee and the Preanalytical Phase Working Group of the EFLM Science Committee.
analytical chemistry
clinical laboratory techniques
clinical practice guideline
contrast agents
diagnostic error
Journal
Clinical chemistry and laboratory medicine
ISSN: 1437-4331
Titre abrégé: Clin Chem Lab Med
Pays: Germany
ID NLM: 9806306
Informations de publication
Date de publication:
06 Dec 2023
06 Dec 2023
Historique:
received:
23
10
2023
accepted:
22
11
2023
medline:
5
12
2023
pubmed:
5
12
2023
entrez:
5
12
2023
Statut:
aheadofprint
Résumé
The Contrast Media Safety Committee of the European Society of Urogenital Radiology has, together with the Preanalytical Phase Working Group of the EFLM Science Committee, reviewed the literature and updated its recommendations to increase awareness and provide insight into these interferences.
Identifiants
pubmed: 38050439
pii: cclm-2023-1184
doi: 10.1515/cclm-2023-1184
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
© 2023 Walter de Gruyter GmbH, Berlin/Boston.
Références
Doorenbos, CJ, Ozyilmaz, A, van Wijnen, M. Severe pseudohypocalcemia after gadolinium-enhanced magnetic resonance angiography. N Engl J Med 2003;349:817–18. https://doi.org/10.1056/nejm200308213490822 .
doi: 10.1056/nejm200308213490822
Otnes, S, Fogh-Andersen, N, Rømsing, J, Thomsen, HS. Analytical interference by contrast agents in biochemical assays. Contrast Media Mol Imaging 2017;2017:1323802. https://doi.org/10.1155/2017/1323802 .
doi: 10.1155/2017/1323802
Morcos, SK, Thomsen, HS, Exley, CM. Members of Contrast Media Safety Committee of European Society of Urogenital Radiology (ESUR) . Contrast media: interactions with other drugs and clinical tests. Eur Radiol 2005;15:1463–8. https://doi.org/10.1007/s00330-004-2600-1 .
doi: 10.1007/s00330-004-2600-1
Dimopoulos, MA, Moreau, P, Terpos, E, Mateos, M, Zweegman, S, Cook, G, et al.. Multiple myeloma: EHA-ESMO Clinical Practice Guidelines for diagnosis, treatment, and follow-up. Ann Oncol 2021;32:309–22. https://doi.org/10.1016/j.annonc.2020.11.014 .
doi: 10.1016/j.annonc.2020.11.014
Quirós, C, Cillero, AI, Bretaña, L, García, M, Prieto, B, Álvarez, FV. In vivo interference of ioversol in serum and urine capillary electrophoresis: an optimized protocol for sample collection. Clin Chem Lab Med 2018;56:e53–5. https://doi.org/10.1515/cclm-2017-0509 .
doi: 10.1515/cclm-2017-0509
Capaldo, C, El Aouni, MC, Laurelli, D, Leven, C, Carré, JL. Detection of monoclonal protein by capillary zone electrophoresis can be challenged by iodinated contrast agent interference: a case report. Biochem Med (Zagreb) 2021;31:021001. https://doi.org/10.11613/bm.2021.021001 .
doi: 10.11613/bm.2021.021001
Lin, CT, Lee, HC, Voon, WC, Yen, H, Tang, M, Chin, T, et al.. Positive interference from contrast media in cardiac troponin I immunoassays. Kaohsiung J Med Sci 2006;22:107–13. https://doi.org/10.1016/s1607-551x(09)70229-3 .
doi: 10.1016/s1607-551x(09)70229-3
Loh, TP, Mok, SF, Ang, BW, Chuah, TY, Sethi, SK. Non-ionic radiologic contrast (iohexol) interferes with laboratory measurements of endocrine hormones. Pathology 2013;45:527–9. https://doi.org/10.1097/pat.0b013e32836359e1 .
doi: 10.1097/pat.0b013e32836359e1
Giasson, J, Chen, Y. A discrepant urine specific gravity. Clin Chem 2012;58:797. https://doi.org/10.1373/clinchem.2011.174219 .
doi: 10.1373/clinchem.2011.174219
Oyaert, MN, De Buyzere, ML, Verstraete, KL, Speeckaert, MM, Delanghe, JR. Iodine containing contrast media and urinary flow cytometry: an unknown interference in automated urine sediment analysis. Clin Chem Lab Med 2021;59:e335–7. https://doi.org/10.1515/cclm-2021-0159 .
doi: 10.1515/cclm-2021-0159
Strasinger, SK, Di Lorenzo, MS. Urinalysis and body fluids , 5th ed. Philadelphia: F. A. Davis; 2008.
Lippi, G, Daves, M, Mattiuzzi, C. Interference of medical contrast media on laboratory testing. Biochem Med (Zagreb) 2014;24:80–8. https://doi.org/10.11613/bm.2014.010 .
doi: 10.11613/bm.2014.010
Daves, M, Lippi, G, Cosio, G, Raffagnini, A, Peer, E, Dangella, A, et al.. An unusual case of a primary blood collection tube with floating separator gel. J Clin Lab Anal 2012;26:246–7. https://doi.org/10.1002/jcla.21512 .
doi: 10.1002/jcla.21512
Kaleta, EJ, Jaffe, AS, Baumann, NA, Block, DR. A case of floating gel. Clin Chem 2012;58:1604–5. https://doi.org/10.1373/clinchem.2012.188862 .
doi: 10.1373/clinchem.2012.188862
Spiritus, T, Zaman, Z, Desmet, W. Iodinated contrast media interfere with gel barrier formation in plasma and serum separator tubes. Clin Chem 2003;49:1187–9. https://doi.org/10.1373/49.7.1187 .
doi: 10.1373/49.7.1187
Sankaran, S, Saharia, GK, Naik, S, Mangaraj, M. Effect of iodinated contrast media on serum electrolyte concentrations in patients undergoing routine contrast computed tomography scan procedure. Int J Appl Basic Med Res 2019;9:217–20. https://doi.org/10.4103/ijabmr.ijabmr_69_19 .
doi: 10.4103/ijabmr.ijabmr_69_19
Arranz-Peña, ML, González-Sagrado, M, Olmos-Linares, AM, Fernández-García, N, Martín-Gil, FJ. Interference of iodinated contrast media in serum capillary zone electrophoresis. Clin Chem 2000;46:736–7. https://doi.org/10.1093/clinchem/46.5.736 .
doi: 10.1093/clinchem/46.5.736
Day, P, Erdahl, S, Eckdahl, S, Bornhorst, J, Jannetto, PJ. Gadolinium-based contrast agents: a clinically significant analytical interference in inductively coupled plasma mass spectrometry elemental analysis. Ann Clin Biochem 2019;56:638–45. https://doi.org/10.1177/0004563219856031 .
doi: 10.1177/0004563219856031
Normann, PT, Froysa, A, Svaland, M. Interference of gadodiamide injection (Omniscan) on the colorimetric determination of serum calcium. Scand J Clin Lab Invest 1995;55:421–6. https://doi.org/10.3109/00365519509104981 .
doi: 10.3109/00365519509104981
Prince, MR, Erel, HE, Lent, RW, Blumenfeld, J, Kent, KC, Bush, HL, et al.. Gadodiamide administration causes spurious hypocalcemia. Radiology 2003;227:639–46. https://doi.org/10.1148/radiol.2273012007 .
doi: 10.1148/radiol.2273012007
Prince, MR, Choyke, PL, Knopp, MV. More on pseudohypocalcemia and gadolinium-enhanced MRI. N Engl J Med 2004;350:87–8. https://doi.org/10.1056/NEJM200401013500120 .
doi: 10.1056/NEJM200401013500120
Zhang, HL, Ersoy, H, Prince, MR. Effects of gadopentetate dimeglumine and gadodiamide on serum calcium, magnesium, and creatinine measurements. J Magn Reson Imag 2006;23:383–7. https://doi.org/10.1002/jmri.20517 .
doi: 10.1002/jmri.20517
Yan, R, Tarr, H, McNally, M, Cartier, LJ, Chen, Y. Interference of gadolinium-based contrast agents on colorimetric calcium assays. Clin Biochem 2014;47:648–53. https://doi.org/10.1016/j.clinbiochem.2013.12.012 .
doi: 10.1016/j.clinbiochem.2013.12.012
Proctor, KA, Rao, LV, Roberts, WL. Gadolinium magnetic resonance contrast agents produce analytic interference in multiple serum assays. Am J Clin Pathol 2004;121:282–92. https://doi.org/10.1309/mga3lc4x8cglx9ch .
doi: 10.1309/mga3lc4x8cglx9ch
Kimura, J, Ishiguchi, T, Matsuda, J, Ohno, R, Nakamura, A, Kamei, S, et al.. Human comparative study of zinc and copper excretion via urine after administration of magnetic resonance imaging contrast agents. Radiat Med 2005;23:322–6.
Harrington, JM, Young, DJ, Essader, AS, Sumner, SJ, Levine, KE. Analysis of human serum and whole blood for mineral content by ICP-MS and ICP-OES: development of a mineralomics method. Biol Trace Elem Res 2014;160:132–42. https://doi.org/10.1007/s12011-014-0033-5 .
doi: 10.1007/s12011-014-0033-5
Lancelot, E. Revisiting the pharmacokinetic profiles of gadolinium-based contrast agents: differences in long-term biodistribution and excretion. Invest Radiol 2016;51:691–700. https://doi.org/10.1097/rli.0000000000000280 .
doi: 10.1097/rli.0000000000000280
van der Molen, AJ, Dekkers, IA, Geenen, RWF, Bellin, MF, Bertolotto, M, Brismar, TB, et al.. Waiting times between examinations with intravascularly administered contrast media: a review of contrast media pharmacokinetics and updated ESUR Contrast Media Safety Committee guidelines. Eur Radiol 2023. https://doi.org/10.1007/s00330-023-10085-5 .
doi: 10.1007/s00330-023-10085-5
Stacul, F, Bertolotto, M, Thomsen, HS, Pozzato, G, Ugolini, D, Bellin, MF, et al.. Iodine-based contrast media, multiple myeloma and monoclonal gammopathies: literature review and ESUR Contrast Media Safety Committee guidelines. Eur Radiol 2018;28:683–91. https://doi.org/10.1007/s00330-017-5023-5 .
doi: 10.1007/s00330-017-5023-5
van Balveren, JA, Verboeket-van de Venne, WPHG, Doggen, CJM, Erdem-Eraslan, L, de Graaf, AJ, Krabbe, JG, et al.. Added value of drug-laboratory test interaction alerts in test result authorisation. Clin Chem Lab Med 2022;60:e108–11. https://doi.org/10.1515/cclm-2022-0077 .
doi: 10.1515/cclm-2022-0077