A coupling, stabilizing, and shaping strategy for breast ultrasound computed tomography (USCT) with a ring array transducer.
Breast ultrasound computed tomography
Coupling
Shaping
Stabilizing
The ring array transducer
Journal
Ultrasonics
ISSN: 1874-9968
Titre abrégé: Ultrasonics
Pays: Netherlands
ID NLM: 0050452
Informations de publication
Date de publication:
30 Nov 2023
30 Nov 2023
Historique:
received:
02
08
2023
revised:
23
11
2023
accepted:
23
11
2023
medline:
7
12
2023
pubmed:
7
12
2023
entrez:
6
12
2023
Statut:
aheadofprint
Résumé
Breast ultrasound computed tomography (USCT) has been gradually promoted to clinical application after years of rapid development. Compared with the traditional handheld ultrasound scanning method, the scanning plane of USCT is fixed at the coronal plane, and the scanning path is designed in advance; the acoustic window is not in direct contact with the breast, a lot of coupling medium (usually degassed water is used to fill the gaps between the probe and breast. The clinical application of breast USTC faces challenges: (1) the processes of water degassing, heating, filling, draining, and cleaning prolong the entire scan cycle and reduce patient throughput. (2) The breast is not stabilized and slight movements of the breast may cause motion artifacts in the USCT images. (3) The non-normal incidence of ultrasound into the breast causes reflected and transmitted signals received with a low signal-to-noise ratio (SNR) or even unable to be detected. This article proposes a coupling, stabilizing, and shaping strategy for the clinical application of USCT with a ring array transducer. The solid gel coupling agent (SGCA) is applied for coupling, and a set of SGCA moldings is designed to stabilize and shape the breast during scanning, the breast shape and size which vary from person to person are simplified into several models. The preparation time is reduced to less than 1 min by replacing disposable moldings. The results show that the breast after shaping is close to round in the coronal plane, and slopes of the breast skin are limited in the sagittal and transverse planes, the breast subcutaneous tissue (fat and glands) has a better contrast-to-noise ratio (CNR) and can be better distinguished in the reflection images than that of the breast without shaping. The mean value of the raw beamformed data which represents the reflection signal amplitude of breast subcutaneous tissue after shaping shows 1.5 times that of the breast without shaping, the signal-to-noise ratio (SNR) of the raw transmission signal data after breast shaping is overall higher than that of the breast without shaping. The application of SGCA moldings for breast coupling, stabilizing, and shaping also benefits establishing a standardized scanning process, the standardized diagnosis of the breast lesion, and the localization of breast lesions.
Identifiants
pubmed: 38056321
pii: S0041-624X(23)00288-3
doi: 10.1016/j.ultras.2023.107212
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
107212Informations de copyright
Copyright © 2023 Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.