A new tidal breathing measurement device detects bronchial obstruction during methacholine challenge test.

Asthma Methacholine challenge test Respiratory parameters Tidal breathing Wearable sensor

Journal

Advances in medical sciences
ISSN: 1898-4002
Titre abrégé: Adv Med Sci
Pays: Netherlands
ID NLM: 101276222

Informations de publication

Date de publication:
13 Dec 2023
Historique:
received: 27 06 2023
revised: 25 10 2023
accepted: 29 11 2023
medline: 15 12 2023
pubmed: 15 12 2023
entrez: 14 12 2023
Statut: aheadofprint

Résumé

Bronchial hyperresponsiveness (BHR), a hallmark of bronchial asthma, is typically diagnosed through a methacholine inhalation test followed by spirometry, known as the methacholine challenge test (MCT). While spirometry relies on proper patients' cooperation and precise execution of forced breathing maneuvers, we conducted a comparative analysis with the portable nanomaterial-based sensing device, SenseGuard™, to non-intrusively assess tidal breathing parameters. In this prospective study, 37 adult participants with suspected asthma underwent sequential spirometry and SenseGuard™ measurements after inhaling increasing methacholine doses. Among the 37 participants, 18 were MCT responders, 17 were non-responders and 2 were excluded due to uninterpretable data. The MCT responders exhibited a significant lung function difference when comparing the change from baseline to maximum response. This was evident through a notable decrease in forced expiratory volume in 1 ​s (FEV This study demonstrates that tidal breathing assessment using SenseGuard™ device reliably detects clinically relevant changes of respiratory parameter during the MCT. It effectively distinguishes between responders and non-responders, with strong agreement to conventional spirometry-measured FEV

Identifiants

pubmed: 38096771
pii: S1896-1126(23)00053-6
doi: 10.1016/j.advms.2023.11.001
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

1-7

Informations de copyright

Copyright © 2023 Medical University of Bialystok. Published by Elsevier B.V. All rights reserved.

Déclaration de conflit d'intérêts

Declaration of competing interest The authors declare no conflict of interests.

Auteurs

Andreas Zachariades (A)

Nicosia Lung Center, Nicosia, Cyprus.

Nadav Bachar (N)

NanoVation-GS LTD., Haifa, Israel. Electronic address: nadavb@nanovation-gs.com.

Noy Danino (N)

NanoVation-GS LTD., Haifa, Israel.

Inbal Shafran (I)

NanoVation-GS LTD., Haifa, Israel.

Ronit Shtrichman (R)

NanoVation-GS LTD., Haifa, Israel.

Gregory Shuster (G)

NanoVation-GS LTD., Haifa, Israel.

Wieland Voigt (W)

NanoVation-GS LTD., Haifa, Israel; Medical Innovation and Management, Steinbeis University Berlin, Berlin, Germany.

Classifications MeSH