Indocyanine green fluorescence versus blue dye, technetium-99M, and the dual-marker combination of technetium-99M + blue dye for sentinel lymph node detection in early breast cancer-meta-analysis including consistency analysis.
Journal
Surgery
ISSN: 1532-7361
Titre abrégé: Surgery
Pays: United States
ID NLM: 0417347
Informations de publication
Date de publication:
Apr 2024
Apr 2024
Historique:
received:
18
07
2023
revised:
13
10
2023
accepted:
25
10
2023
medline:
18
3
2024
pubmed:
15
12
2023
entrez:
14
12
2023
Statut:
ppublish
Résumé
Axillary sentinel lymph node biopsies are standard of care in patients with breast cancer and no clinically apparent metastases. Traditionally, technetium-99m, blue dye, or both have been used to identify sentinel lymph nodes. However, blue dyes miss up to 40% of sentinel lymph nodes, while technetium-99m use is complex, costly, and exposes patients to radiation. Over the past decade, studies have consistently found the biologically inert fluorescent indocyanine green to be 95% to 100% sensitive in detecting breast cancer sentinel lymph nodes, yet indocyanine green remains infrequently used. We conducted an extensive meta-analysis comparing indocyanine green against blue dye, technetium-99m, and the dual-marker combination of technetium-99m + BD. Unlike prior meta-analyses that only assessed either per-case or per-node sentinel lymph node detection, we analyzed the following 5 metrics: per-case and per-node sentinel lymph node detection and metastasis-positive sentinel lymph node sensitivity, and mean number of sentinel lymph nodes/case. We further examined the consistency and magnitude of between-study superiority and statistically significant within-study superiority of each marker against others. For every metric and analysis approach, indocyanine green was clearly superior to blue dye and at least non-inferior, if not superior, to technetium-99m and technetium-99m + blue dye. Assessing the consistency of superiority by at least 2.0%, indocyanine green was superior to blue dye 73 times versus 1, to technetium-99m 42 times versus 9, and to technetium-99m + blue dye 6 times versus 0. Within-study statistically significant differences favored indocyanine green over blue dye 29 times versus 0 and over technetium-99m 11 times versus 2. For sentinel lymph node detection in patients with breast cancer with no clinically apparent metastases, indocyanine green is clearly and consistently superior to blue dye and either non-inferior or superior to technetium-99m and technetium-99m + blue dye.
Sections du résumé
BACKGROUND
BACKGROUND
Axillary sentinel lymph node biopsies are standard of care in patients with breast cancer and no clinically apparent metastases. Traditionally, technetium-99m, blue dye, or both have been used to identify sentinel lymph nodes. However, blue dyes miss up to 40% of sentinel lymph nodes, while technetium-99m use is complex, costly, and exposes patients to radiation. Over the past decade, studies have consistently found the biologically inert fluorescent indocyanine green to be 95% to 100% sensitive in detecting breast cancer sentinel lymph nodes, yet indocyanine green remains infrequently used.
METHODS
METHODS
We conducted an extensive meta-analysis comparing indocyanine green against blue dye, technetium-99m, and the dual-marker combination of technetium-99m + BD. Unlike prior meta-analyses that only assessed either per-case or per-node sentinel lymph node detection, we analyzed the following 5 metrics: per-case and per-node sentinel lymph node detection and metastasis-positive sentinel lymph node sensitivity, and mean number of sentinel lymph nodes/case. We further examined the consistency and magnitude of between-study superiority and statistically significant within-study superiority of each marker against others.
RESULTS
RESULTS
For every metric and analysis approach, indocyanine green was clearly superior to blue dye and at least non-inferior, if not superior, to technetium-99m and technetium-99m + blue dye. Assessing the consistency of superiority by at least 2.0%, indocyanine green was superior to blue dye 73 times versus 1, to technetium-99m 42 times versus 9, and to technetium-99m + blue dye 6 times versus 0. Within-study statistically significant differences favored indocyanine green over blue dye 29 times versus 0 and over technetium-99m 11 times versus 2.
DISCUSSION
CONCLUSIONS
For sentinel lymph node detection in patients with breast cancer with no clinically apparent metastases, indocyanine green is clearly and consistently superior to blue dye and either non-inferior or superior to technetium-99m and technetium-99m + blue dye.
Identifiants
pubmed: 38097484
pii: S0039-6060(23)00820-6
doi: 10.1016/j.surg.2023.10.021
pii:
doi:
Substances chimiques
Coloring Agents
0
Indocyanine Green
IX6J1063HV
Technetium
7440-26-8
Radiopharmaceuticals
0
Types de publication
Meta-Analysis
Journal Article
Review
Langues
eng
Sous-ensembles de citation
IM
Pagination
963-973Informations de copyright
Copyright © 2023 The Authors. Published by Elsevier Inc. All rights reserved.