The Allegra transcatheter heart valve: Long-term clinical and echocardiographic outcomes.

Allegra TAVR aortic stenosis outcomes transcatheter aortic valve transcatheter aortic valve replacement

Journal

The Journal of invasive cardiology
ISSN: 1557-2501
Titre abrégé: J Invasive Cardiol
Pays: United States
ID NLM: 8917477

Informations de publication

Date de publication:
Dec 2023
Historique:
medline: 18 12 2023
pubmed: 18 12 2023
entrez: 18 12 2023
Statut: ppublish

Résumé

The Allegra-THV is a novel, self-expanding THV with supra-annular bovine leaflets. The valve is available in 3 different sizes and is delivered through an 18 French sheath. To determine the safety and efficacy of the Allegra transcatheter heart valve (THV; Biosensors) for the treatment of severe aortic valve stenosis under real-world conditions. Consecutive patients undergoing transcatheter aortic valve replacement (TAVR) at the Heart-Centre Lucerne with the Allegra-THV were included. Echocardiographic data were collected at baseline, before discharge, and at 1-year follow-up; clinical outcomes were recorded for up to 3 years. Clinical endpoints were defined according to the definitions of the Valve-Academic-Research-Consortium. One hundred-three patients (age 81 ± 7 years, 63% women) were enrolled. Median European System for Cardiac Operative Risk Evaluation II score was 4.1% (IQR 1.8%-4.2%). Mean aortic valve gradient was 6.9 ± 3.3 mm Hg and 7.7 ± 3.3 mm Hg, and an effective orifice area was 2.1 ± 0.5 cm2 and 2.0 ± 0.5 cm2 at 30 days and 1-year follow-up, respectively. More than mild paravalvular leak was observed in 2.0% of patients at 30 days and 3.3% at 1 year. At 1-year follow-up, 14.7% of patients required implantation of a new permanent pacemaker, 1 patient had endocarditis with an uneventful clinical course and good THV-function after antibiotic therapy, and no thrombosis, structural-valve-detoriation (SVD), or non-SVD had occurred. At 3-year follow-up, rates of all-cause and cardiovascular mortality were 31.4% and 18.8%, respectively. Transfemoral implantation of the Allegra-THV resulted in favorable clinical and echocardiographic outcomes at up to 3-year follow-up. Head-to-head randomized clinical trials are necessary to determine if the Allegra-THV valve performs as well as current generation valves.

Identifiants

pubmed: 38108869
doi: 10.25270/jic/23.00163
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Auteurs

Mathias Wolfrum (M)

Heart Center Lucerne, Luzerner Kantonsspital, Lucerne, Switzerland.

Federico Moccetti (F)

Heart Center Lucerne, Luzerner Kantonsspital, Lucerne, Switzerland.

Nina Conrad (N)

Heart Center Lucerne, Luzerner Kantonsspital, Lucerne, Switzerland.

Lucca Loretz (L)

Heart Center Lucerne, Luzerner Kantonsspital, Lucerne, Switzerland.

Matthias Bossard (M)

Heart Center Lucerne, Luzerner Kantonsspital, Lucerne, Switzerland.

Adrian Attiger-Toller (A)

Heart Center Lucerne, Luzerner Kantonsspital, Lucerne, Switzerland.

Florim Cuculi (F)

Heart Center Lucerne, Luzerner Kantonsspital, Lucerne, Switzerland.

Stefan Toggweiler (S)

Heart Center Lucerne, Luzerner Kantonsspital, Lucerne, Switzerland.

Classifications MeSH