RAPID aneurysm accurately measures aneurysm size on CT angiography compared to three-dimensional digital subtraction angiography.
Aneurysm
CTA
artificial intelligence
automated
digital subtraction angiography (DSA)
measurement
rupture
size
Journal
Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences
ISSN: 2385-2011
Titre abrégé: Interv Neuroradiol
Pays: United States
ID NLM: 9602695
Informations de publication
Date de publication:
27 Dec 2023
27 Dec 2023
Historique:
medline:
27
12
2023
pubmed:
27
12
2023
entrez:
27
12
2023
Statut:
aheadofprint
Résumé
Cerebral aneurysms are often identified and characterized on non-invasive CT Angiography (CTA) images, but digital subtraction angiography (DSA) is the gold standard for aneurysm evaluation. We compared cerebral aneurysm size measurements as measured from CTA processed by a semi-automated artificial intelligence software program (RAPID Aneurysm) and three-dimensional rotational DSA (3D-DSA). We performed a retrospective cohort study of consecutive patients with a cerebral aneurysm who underwent CTA and DSA with 3D reformations. CTA images were processed by RAPID Aneurysm to determine aneurysm height, width, and neck width. The reference standard was aneurysm measurements on 3D-DSA as measured by two neurointerventionalists. Both readers were blinded to RAPID Aneurysm measurements. Correlation and bias between these measurements were determined. Results from 50 patients with 50 aneurysms were compared. 32 patients (64%) were female. Median age was 65 (IQR: 56.25-71.75). 37 patients (74%) presented with ruptured aneurysms. The aneurysms represented a range of aneurysm sizes (1.9-33.3 mm; IQR 3.6-7.2 mm). RAPID Aneurysm size measurements showed excellent correlation and low bias (correlation, mean difference) when compared to the reference standard for aneurysm height (0.98, -0.9 mm), width (0.98, 0.1 mm), and neck width (0.94, 1.1 mm). The inter-reader comparison between the two neurointerventionalists was similarly excellent for aneurysm height (0.97, -0.4 mm), width (0.98, -0.2 mm), and neck width (0.89, 0.8 mm). RAPID Aneurysm measurement of cerebral aneurysm height, width, and neck width on CTA is strongly correlated to expert neurointerventionalist measurements on 3D-DSA.
Sections du résumé
BACKGROUND
BACKGROUND
Cerebral aneurysms are often identified and characterized on non-invasive CT Angiography (CTA) images, but digital subtraction angiography (DSA) is the gold standard for aneurysm evaluation.
OBJECTIVE
OBJECTIVE
We compared cerebral aneurysm size measurements as measured from CTA processed by a semi-automated artificial intelligence software program (RAPID Aneurysm) and three-dimensional rotational DSA (3D-DSA).
METHODS
METHODS
We performed a retrospective cohort study of consecutive patients with a cerebral aneurysm who underwent CTA and DSA with 3D reformations. CTA images were processed by RAPID Aneurysm to determine aneurysm height, width, and neck width. The reference standard was aneurysm measurements on 3D-DSA as measured by two neurointerventionalists. Both readers were blinded to RAPID Aneurysm measurements. Correlation and bias between these measurements were determined.
RESULTS
RESULTS
Results from 50 patients with 50 aneurysms were compared. 32 patients (64%) were female. Median age was 65 (IQR: 56.25-71.75). 37 patients (74%) presented with ruptured aneurysms. The aneurysms represented a range of aneurysm sizes (1.9-33.3 mm; IQR 3.6-7.2 mm). RAPID Aneurysm size measurements showed excellent correlation and low bias (correlation, mean difference) when compared to the reference standard for aneurysm height (0.98, -0.9 mm), width (0.98, 0.1 mm), and neck width (0.94, 1.1 mm). The inter-reader comparison between the two neurointerventionalists was similarly excellent for aneurysm height (0.97, -0.4 mm), width (0.98, -0.2 mm), and neck width (0.89, 0.8 mm).
CONCLUSION
CONCLUSIONS
RAPID Aneurysm measurement of cerebral aneurysm height, width, and neck width on CTA is strongly correlated to expert neurointerventionalist measurements on 3D-DSA.
Identifiants
pubmed: 38150662
doi: 10.1177/15910199231222676
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
15910199231222676Déclaration de conflit d'intérêts
Declaration of conflicting interestsJJH and AMS are members of the medical and scientific advisory board for iSchemaView.